[Discrimination of musical pitch with cochlear implants].

BACKGROUND: Numerous people with cochlear implants (CI) report difficulties in listening to music even though they understand speech quite well. One reason for this is a limited perception of pitch and timbre. In this study ability of adult CI subjects to discriminate musical pitch is investigated. PATIENTS AND METHODS: In two psychoacoustic experiments, each conducted in 10 adult CI subjects provided with MED-EL Combi 40+ cochlear implant devices and a control group of subjects with normal hearing, individual discrimination abilities for musical pitch perception were determined. To investigate the influence of the group of instruments on discrimination ability, stimuli representing four different groups of instruments were used: woodwind (clarinet), brass (trumpet), strings (violin) and keyboard instruments (piano). RESULTS: The discrimination thresholds determined varied between individual CI subjects, and on average they were significantly higher for the piano than for the other three instruments. CONCLUSIONS: The results show that in subjects with CI pitch perception differs from instrument to instrument and is in general worse than in persons with normal hearing.

Adult↗

Room-temperature magneto-optics of ferromagnetic transition-metal-doped ZnO thin films.

Magneto-optic studies of ZnO doped with transition metals Co, Mn, V, and Ti indicate a significant magnetic circular dichroism (MCD) at the ZnO band edge at room temperature, together with an associated dispersive Faraday rotation. Similar spectra occur for each dopant, which implies that the ferromagnetism is an intrinsic property of the bulk ZnO lattice. At 10 K, additional paramagnetic contributions to the MCD are observed, but above about 150 K, the magnitude of the MCD signal is dominated by the ferromagnetism and is almost temperature independent. The MCD at the ZnO band edge shows room temperature hysteretic behavior.

Journal Article↗

P1 site-specific recombination: nucleotide sequence of the recombining sites.

Site-specific recombination between molecules of bacteriophage P1 DNA occurs at sites called loxP and requires the action of a protein that is the product of the P1 cre gene. Although recombination between two loxP sites is very efficient, recombination between loxP and a unique site in the bacterial chromosome (loxB) is inefficient and generates two hybrid lox sites called loxR and loxL. We present here the nucleotide sequences of all four lox sites. Analysis of these sequences indicates that (i) a region of extensive homology is not present at the loxP X loxB crossover point, in contrast to the 15-base pair common-core sequence in the bacteriophage lambda att sites, and (ii) the sites contain a region of dyad symmetry with 8- to 13-base pair inverted repeats separated by an 8- to 9-base pair sequence. The loxP X loxB crossover point falls in the sequence that separates the inverted repeats, and deletions that remove either the left or the right inverted repeat of loxP inactivate the site. These two observations are consistent with the conclusion that the region of dyad symmetry is important in los recombination. We have shown further that the loxP X loxP crossover point occurs in a 63-base pair sequence containing the loxP X loxB crossover point, suggesting that, despite the great difference in efficiencies of the two reactions, the crossover points may occur at the same place in both. Explanations for the different recombination properties of the various lox sites are discussed.

Base Sequence↗

A novel role for site-specific recombination in maintenance of bacterial replicons.

If daughter copies of unit-copy replicons recombine with each other, a replicon dimer results that cannot be partitioned equally to daughter cells at cell division. We present evidence that dimer formation interferes with plasmid equipartition in the case of a miniplasmid derived from the unit-copy plasmid prophage of bacteriophage P1. Asymmetric partition occurs, leading to a relatively high rate of loss of the plasmid from the growing population. In contrast, the wild-type P1 plasmid is maintained very efficiently in host cells. We show that this efficient maintenance is due to the presence of the loxP-cre site-specific recombination system present on the intact P1 plasmid. This system promotes rapid recombination between two loxP sites on dimer molecules, resolving them into monomeric substrates for proper partition. We suggest that bacterial replicons that are maintained with great accuracy in recombination-proficient cells might also encode high-efficiency recombination systems.

Base Sequence↗

Speech understanding with the CIS and the n-of-m strategy in the MED-EL COMBI 40+ system.

Speech tests have been performed on 6 subjects for comparing the standard 12-channel continuous interleaved sampling (CIS) strategy (CIS12), the 7-channel CIS strategy (CIS7) and the 7-of-12 strategy in the MED-EL COMBI 40+ system. An ABAB experimental design was used whereby each strategy was reversed and replicated. Speech tests were performed in quiet (vowels, consonants, monosyllables, sentences) and noise (sentences). Results showed that for vowels, CIS12 is significantly superior to CIS7, for consonants and sentences CIS12, CIS7 and 7-of-12 performed equally well, and that for monosyllables 7-of-12 is significantly superior to both CIS12 and CIS7. In addition, 7-of-12 is superior to CIS7 by almost the same amount as CIS12, but in this case the difference is not significant. Further, all strategies have been found to be equally robust in noise with respect to sentence understanding. The differences between CIS12 and 7-of-12 on the one hand and CIS7 on the other hand may be attributed to decreased spectral resolution of the latter. The fact that - in contrast to what has been reported for the SPEAK strategy - 7-of-12 is equally robust in noise as the CIS strategies is explained by the use of higher stimulation rates, wider frequency bands and a higher percentage of channels stimulated in each cycle.

Adult↗

Comparison of the TEMPO+ ear-level speech processor and the cis pro+ body-worn processor in adult MED-EL cochlear implant users.

A study was conducted to compare the new MED-EL TEMPO+ ear-level speech processor with the CIS PRO+ body-worn processor in the COMBI 40/COMBI 40+ implant system. Speech tests were performed in 46 experienced subjects in two test sessions approximately 4 weeks apart. Subjects were switched over from the CIS PRO+ to the TEMPO+ in the first session and used only the TEMPO+ in the time between the two sessions. Speech tests included monosyllabic word tests and sentence tests via the telephone. An adaptive noise method was used to adjust each subject's scores to approximately 50%. Additionally, subjects had to complete a questionnaire based on their 4 weeks of experience with the TEMPO+. The speech test results showed a statistically significant improvement in the monosyllabic word scores with the TEMPO+. In addition, in the second session, subjects showed a significant improvement when using the telephone with the TEMPO+, indicating some learning in this task. In the questionnaire, the vast majority of subjects found that the TEMPO+ allows equal or better speech understanding and rated the sound quality of the TEMPO+ higher. All these objective and subjective results indicate the superiority of the TEMPO+ and are mainly attributed to a new coding strategy called CIS+ and its implementation in the TEMPO+. In other words, based on the results of this study, it appears that after switching over from the CIS PRO+ to the TEMPO+, subjects are able to maintain or even improve their own speech understanding capability.

Adult↗