Steroid eluting high impedance pacing leads decrease short and long-term current drain: results from a multicenter clinical trial. CapSure Z investigators.

Pacemaker lead technology has changed considerably over the past decades. The widespread use of low polarization highly porous electrodes and steroid elution electrodes has resulted in low chronic pacing thresholds, as well as a decrease in the incidence of exit block. Efforts to develop pacing leads with high impedance might theoretically lead to lower lead current drain, which is a component of battery capacity. Pulse generator longevity can be increased without sacrificing pacemaker capabilities if pacing current drain can be decreased. Decreasing the size of the stimulation electrode results in increased pacing impedance, and if pacing thresholds are unchanged, a decreased current drain is predicted by Ohm's law (I = V/R). There is limited data available on the pacing characteristics of large numbers of patients with high impedance leads, despite their recent general availability and increasing widespread use. This multicenter, controlled trial examined the differences in performance between standard steroid-eluting pacing leads in the atrium (Medtronic model 5524) and ventricle (Medtronic model 5024), and new high impedance steroid-eluting pacing leads in the atrium (Medtronic model 5534) and ventricle (Medtronic model 5034). Measurements of bipolar pacing thresholds at 2.5 V, pacing impedance, and sensing thresholds were determined within 24 hours of pacemaker implantation, and at 0.5, 1, 3, 6 and 12 months after pacemaker implantation in 609 patients. Pacing and sensing thresholds were similar for the control and high impedance leads at all times except for a slightly larger R wave with the high impedance leads at implantation and 12 months. The mean impedance of the high impedance pacing leads in the atrium and ventricle at 12 months was 992 +/- 175 and 1,080 +/- 220 omega, compared to 522 +/- 69 and 600 +/- 89 omega for the standard pacing leads in the atrium and ventricle (P < or = 0.001 for the high impedance leads compared to standard leads in each chamber). The mean atrial lead current (measured at 2.5 V) at 12 months was 2.6 +/- 0.5 mA with the high impedance lead, and 4.9 +/- 0.7 mA with the standard lead in the atrium (P < or = 0.001). In the ventricle, the mean lead current at 12 months was 2.4 +/- 0.4 mA with the high impedance pacing lead and 4.3 +/- 0.6 mA with the standard lead (P < or = 0.001). High impedance leads are associated with lower lead current drain than standard pacing leads in the atrium and ventricle for up to 1 year. No clinically important differences in sensing characteristics was noted with the high impedance leads in the atrium or ventricle compared to standard pacing leads. High impedance leads may result in increased pulse generator longevity.

Aged↗

Cloning and characterization of the dnaK heat shock operon of the marine bacterium Vibrio harveyi.

We cloned the DNA region of the Vibrio harveyi chromosome containing the heat shock genes dnaK and dnaJ and sequenced them. These genes are arranged in the chromosome in the order dnaK-dnaJ, as in other proteobacteria of the alpha and gamma subdivisions. The dnaK gene is 1923 nucleotides in length and codes for a protein of 640 amino acid residues, with a predicted molecular mass of 69,076 Da and 81.2% similarity to the DnaK protein of Escherichia coli. The V. harveyi dnaJ gene has a coding sequence of 1158 nucleotides. The predicted DnaJ protein contains 385 amino acids, its calculated molecular mass is 41,619 Da and it has 74.7% similarity to the DnaJ protein of E. coli. Northern hybridization experiments with RNA from V. harveyi cells and a DNA probe carrying both the dnaK and dnaJ genes showed a single, heat-inducible transcript, indicating that these genes form an operon. Primer extension analysis revealed five heat-inducible transcriptional start sites upstream of the dnaK gene, two of which (T1 and T4) are preceded by sequences typical of the E. coli heat shock promoters recognized by the sigma 32 (sigma32) factor. Location of these promoters is highly similar to that of the E. coli dnaK promoters. No transcriptional start sites were detected upstream of the dnaJ gene. The V. harveyi dnaKJ operon cloned in a plasmid in E. coli cells was transcribed in a sigma32 dependent manner and the size of the transcript, the kinetics of transcription, and the transcriptional start sites were as in V. harveyi cells. This indicates a high conservation of the transcriptional heat shock regulatory elements between E. coli and V. harveyi, both belonging to the gamma subdivision of proteobacteria. We tested the ability of the cloned dnaKJ genes to complement E. coli dnaK and dnaJ mutants and found that V. harveyi DnaJ restored a thermoresistant phenotype to dnaJ mutants and enabled lambda phage to grow in the mutant cells. V. harveyi DnaK did not suppress the thermosensitivity of dnaK mutants but complemented the dnaK deletion mutant with respect to growth of lambda phage. V. harveyi DnaK, in contrast to DnaJ, failed to modulate the heat shock response in E. coli. Our results suggest that the DnaK chaperone may be more species specific than the DnaJ chaperone.

Amino Acid Sequence↗

Enzymatic deacylation of teicoplanin followed by reductive alkylation: synthesis and antibacterial activity of new glycopeptides.

Novel glycopeptides derived from teicoplanin were prepared and evaluated for activity against antibiotic-resistant gram-positive pathogens. Removal of the fatty acid sidechains of teicoplanin was accomplished by enzymatic deacylation. The resulting deacylated teicoplanin was subjected to reductive alkylation resulting in mono- and di-alkylated compounds at the 2 possible primary amines. Deacylated teicoplanin was less active than teicoplanin against enterococci and staphylococci (MIC > or =32 microg/ml). All mono- and di-alkylated products regained some activity, and some had potent activity against both staphylococci and glycopeptide-resistant enterococci. MICs of the most potent di-alkylated compounds ranged from 0.25 approximately 2 microg/ml against glycopeptide-resistant enterococci.

Alkylation↗

False-positive behavior with the dP/dt sensing pacemaker: a rare complication of a physiological sensor.

As with "nonphysiological" devices, sensors that directly measure physiological variables have the potential to measure unexpected signals and for the physiological parameter being measured to respond in an unexpected manner. We present the case of a dP/dt sensing pacing system that functioned normally for 2 months and then developed upper rate behavior due to the sensing of a high frequency artifact on the pressure recording. Our case and others cited reinforce the need for future physiological rate responsive pacemakers to incorporate a second sensor to provide for backup rate response in cases of inappropriate rate response.

Aged↗

Steroid elution improves the stimulation threshold in an active-fixation atrial permanent pacing lead. A randomized, controlled study. Model 4068 Investigators.

BACKGROUND: Prior work suggests that the addition of a steroid-eluting reservoir to a passive-fixation permanent pacemaker lead improves the stimulation threshold; however, no large randomized study has addressed this tissue. Over the last several years, there has been an increase in enthusiasm for the use of active-fixation permanent pacemaker leads for various reasons in spite of the generally accepted notion that active-fixation leads have higher stimulation thresholds. METHODS AND RESULTS: This multicenter, randomized, controlled study examined the difference in performance between a standard active-fixation atrial lead (Medtronic model 4058) and a steroid-eluting lead (Medtronic model 4068). Stimulation thresholds were obtained in a four-point strength-duration fashion. Evaluations of sensing and impedance were performed as well. These evaluations were performed at implantation, at weeks 1 through 4, and at weeks 6, 12, 24, and 52. Stimulation thresholds were significantly better in the steroid lead than in the nonsteroid lead at each measurement point from 1 week to 12 months. The mean 1.6-V stimulation threshold at 12 months was 0.19 +/- 0.2 ms in the steroid lead and 0.41 +/- 0.30 ms in the control lead. No acute peaking was observed with the steroid lead, whereas significant peaking was observed with the control lead. There was no difference in long-term sensing or impedance. CONCLUSIONS: Inclusion of a steroid-eluting reservoir in an active-fixation permanent pacing lead improved stimulation thresholds in both the subacute and chronic periods and therefore should extend pulse-generator longevity.

Aged↗

Treatment of patients with prior exit block using a novel steroid-eluting active fixation lead. Model 4068 Investigators.

An increased interest has developed in active fixation leads for several reasons. Exit block is an uncommon complication that is seen with both active and passive fixation leads. Exit block has not been a significant problem with passive fixation steroid-eluting leads and has been treated with these leads. A new steroid-eluting active fixation lead was examined for its performance in patients in whom exit block had previously occurred. The lead function was evaluated prospectively in 24 patients with a history of exit block (15 ventricular and 9 atrial). The results in patients with atrial exit block are encouraging with an average chronic stimulation threshold of 0.19 msecs at 2.5 volts. Results in the ventricle are less encouraging with 3 occurrences of recurrent exit block in 15 patients; however, the remaining patients had a good mean threshold of 0.21 +/- 0.11 msecs at 2.5 volts. There were a remarkable number of non-lead related complications suggesting that this is a substantially different group than routine implantations.

Cardiac Pacing, Artificial↗

[Acute limb ischemia after arterial surgery].

The causes of acute limb ischaemia after reconstructive arterial surgery may include excessive peripheral resistance, considerable arterial blood pressure fall, technical error, separation of the intima, or embolization by dislodged thromboembolic material. The purpose of the work was and analysis of causes and results of treatment in the clinical material in the period 1988-1991. For acute limb ischaemia after arterial surgery 45 patients were treated. The main causes of ischaemia were: considerable blood pressure fall--10 patients, excessive peripheral resistance--11 patients, and embolization by dislodged thromboembolic material--11 patients. The obtained results are unsatisfactory and fraught with a great number of complications. Good result was obtained in 30 patients (66.6%), limb was amputated in 7 cases (15.6%), and eight patients died (17.8%).

Adult↗

Ultrastructural observations of nuclear bodies in the epithelial cells of human conjunctiva.

Nuclear bodies (NBs) are intranuclear structures described in normal and pathologically altered cells of humans and animals. The NBs are 0.3-1.5 microns round structures. Their function is unknown. In the present paper, we describe NBs in the nuclei of the conjunctiva epithelial cells in one patient with cicatricial pemphigoid (CP) and in an another one without conjunctival pathology. We observed increase in the frequency of the NBs of type I occurring in the conjunctival cells in CP patient as compared to the healthy control. This is the first report to describe nuclear bodies in the human conjunctiva.

Cell Nucleus↗

Entrainment onset in a pacemaker model of reentrant ventricular tachycardia: insight into localization of critical elements of a reentrant circuit.

We investigated entrainment in a pacemaker model of reentrant ventricular tachycardia (VT) created in the intact dog heart using a VAT pacemaker with both electrodes on the ventricular epicardium. This produced an incessant wide QRS tachycardia originating from the pacing site with a cycle length equal to the conduction time between the sensing and pacing site plus the pacemaker AV delay. The conduction time between entrainment sites and the critical elements of the reentrant pathway (sensing and pacing sites) was determined by pacing at a comparable cycle length during sinus rhythm. Entrainment was achieved in 12 tachycardias with pacing at 1-4 sites at cycle lengths 10-100 msec shorter than tachycardia and confirmed by constant QRS fusion, progressive QRS fusion, and coupling of the first nonpaced QRS or intracardiac electrogram at the entraining cycle length. By least squares regression, the timing of entrainment onset (first reset of pacing or sensing site electrogram) measured by the prematurity of the local electrogram at the entraining site was highly correlated to the shortest conduction time between the entraining site and the circuit (F value of 84.7 and R = 0.752 [P less than 0.001]). Therefore, the timing of entrainment onset maybe useful in predicting the conduction time from the entraining site to critical elements of a reentrant circuit and may assist in localization of the reentrant pathway.

Animals↗

Pyrrolo(1,4)benzodiazepine antitumor antibiotics. In vitro interaction of anthramycin, sibiromycin and tomaymycin with DNA using specifically radiolabelled molecules.

Anthramycin, tomaymycin and sibiromycin are pyrrolo(1,4)benzodiazepine antitumor antibiotics. These compounds react with DNA and other guanine-containing polydeoxynucleotides to form covalently bound antibiotic - polydeoxynucleotide complexes. Experiments utilizing radiolabelled antibiotics have led to the following conclusions: 1. Sibiromycin reacts much faster than either anthramycin or tomaymycin with DNA. 2. At saturation binding the final antibiotic to base ratios for sibiromycin, anthramycin and tomaymycin are 1 : 8.8,1: 12.9, and 1 : 18.2, respectively. 3. No reaction with RNA or protein occurs with the pyrrolo(1,4)benzodiazepine antibiotics. 4. Sibiromycin effectively competes for the same DNA binding sites as anthramycin and tomaymycin; however, there is only partial overlap for the same binding sites between anthramycin and tomaymycin. 5. Whereas all three pyrrolo(1,4)benzodiazepine antibiotic-DNA complexes are relatively stable to alkaline conditions, their stability under acidic conditions increases in the order tomaymycin, anthramycin and sibiromycin. 6. No loss of non-exchangeable hydrogens in either the pyrrol ring or the side chains of these antibiotics occurs upon formation of their complexes with DNA. 7. Unchanged antibiotic has been demonstrated to be released upon acid treatment of the anthramycin-DNA and tomaymycin-DNA complexes. 8. A Schiff base linkage between the antibiotics and DNA has been eliminated. The comparative reactivity of the three antibiotics towards DNA and the stability of their DNA complexes is discussed in relation to their structures. A working hypothesis for the formation of the antibiotic-DNA covalent complexes is proposed based upon the available information.

Anthramycin↗