PubMed Health⌕ Search

Biomedical subjects

M von Mengershausen

Publications and source records attributed to M von Mengershausen.

2 recordsLinked to original sources

3D diffusion tensor imaging with 2D navigated turbo spin echo.

A Cartesian two-dimensional navigator with variable orientation for online motion correction is introduced. It corrects for all possible zeroth- and first-order phase errors due to rigid-body motion of a subject during the diffusion-weighting preparation. The technique is developed for the application of three-dimensional (3D) imaging sequences, which offer the opportunity of high-resolution diffusion-weighted imaging, or diffusion tensor imaging (DTI) with isotropic voxel resolution. The navigator was applied to a displaced 3D turbo spin-echo sequence with an ECG-gated diffusion preparation to avoid phase errors due to gross brain pulsation. Online and offline corrected in vivo images acquired with this sequence are compared to investigate the advantages of online correction. Also eigenvector maps of the diffusion tensor are presented with an isotropic resolution of 1 mm3, which indicate that this new navigator technique is a promising approach for high-resolution DTI.

Adult↗

Online motion correction for diffusion-weighted segmented-EPI and FLASH imaging.

This paper explores the application of online motion correction using navigator echoes to the segmented-EPI and FLASH techniques. In segmented EPI this has the advantage over post-acquisition correction that the position in k-space of each segment is no longer subject to arbitrary shifts caused by rotation. In diffusion-weighted FLASH it has the advantage that the full magnetisation can be utilised in comparison to other methods of eliminating the sensitivity to bulk motion, in which the sensitivity is halved. Healthy subjects were investigated on a 3 T whole-body system in which the hardware has been modified so that navigator echoes can be recorded on a personal computer which generates the necessary magnetic field gradient correction pulses and shifts in the Larmor frequency within 800 micros. ECG triggering was used to avoid the period of non-rigid-body brain motion. Two orthogonal navigator echoes were employed. For segmented EPI it was found essential to minimise the T2* weighting of the navigator echoes to about 10 ms to obtain reliable results. High quality images were obtained for both methods examined. Online motion correction brings direct benefits to both the diffusion-weighted segmented-EPI and FLASH techniques.

Brain↗