Publications and source records attributed to Maciej Zborowski.

At least 19 recordsLinked to original sources

Blood progenitor cell separation from clinical leukapheresis product by magnetic nanoparticle binding and magnetophoresis.

Positive selection of CD34+ blood progenitor cells from circulation has been reported to improve patient recovery in applications of autologous transplantation. Current magnetic separation methods rely on cell capture and release on solid supports rather than sorting from flowing suspensions, which limits the range of therapeutic applications and the process scale up. We tested CD34+ cell immunomagnetic labeling and isolation from fresh leukocyte fraction of peripheral blood (leukapheresis) using the continuous quadrupole magnetic flow sorter (QMS), consisting of a flow channel (SHOT, Greenville, IN) and a quadrupole magnet with a maximum field intensity (B(o)) of 1.42 T and a mean force field strength (S(m)) of 1.45 x 10(8) TA/m(2). Both the sample magnetophoretic mobility (m) and the inlet and outlet flow patterns highly affect the QMS performance. Seven commercial progenitor cell labeling reagent combinations were quantitatively evaluated by measuring magnetophoretic mobility of a high CD34 expression cell line, KG-1a, using the cell tracking velocimeter (CTV). The CD34 Progenitor Cell Isolation Kit (Miltenyi Biotec, Bergisch Gladbach, Germany) showed the strongest labeling of KG-1a cells and was selected for progenitor cell enrichment from 11 fresh and 11 cryopreserved clinical leukapheresis samples derived from different donors. The CD34+ cells were isolated with a purity of 60-96%, a recovery of 18-60%, an enrichment rate of 12-169, and a throughput of (1.7-9.3) x 10(4) cells/s. The results also showed a highly regular dependence of the QMS performance on the flow conditions that agreed with the theoretical predictions based on the CD34+ cell magnetophoretic mobility.

Antigens, CD34↗

Application of immunomagnetic cell enrichment in combination with RT-PCR for the detection of rare circulating head and neck tumor cells in human peripheral blood.

Detection of rare, circulating tumor cells (CTC's) in human peripheral blood is a potential indicator of prognosis and diagnosis in oncology. Typical methods to detect these CTC's are either by immunocytochemistry (ICCS) or RT-PCR. However without accurate, rapid, and reproducible enrichment processes, these detection techniques are labor intensive and/or unreliable. In this article, a repeatable enrichment process that included a flow-through immunomagnetic cell separation system, the quadrupole magnetic sorter (QMS) was optimized with the aid of a statistical analysis software package. The QMS was operated in a negative mode of operation by immunomagnetically targeting normal human peripheral blood lymphocytes (PBL) through the CD45 surface marker. Three head and neck squamous carcinoma cell lines (HNSCC), Detroit-562, SCC-4, and CAL-27, were used to determine the sensitivity of RT-PCR for the epidermal growth factor receptor (EGFR) in spiked PBL. The detection purity needed for detection was found to be one cell in 10(4), one cell in 10(3), and one cell in 10(5) for the Detroit-562, SCC-4, and CAL-27, respectively. The actual number of cancer cells needed for RT-PCR detection ranged from 30 to 1 cell. To mimic the potential concentration of rare CTC present in peripheral blood of cancer patients, the spiking concentration was chosen to be one cancer cell per 10(5) total leukocytes from healthy donors. Using a single step immunomagnetic labeling, the final, optimized enrichment process produced a 57.6 +/- 30.3-fold (n = 6) enrichment of the rare cancer cells with a final cancer cell recovery of (77.8 +/- 6.6)%.

Biomarkers, Tumor↗

Binding affinities/avidities of antibody-antigen interactions: quantification and scale-up implications.

Bioaffinity interactions have been, and continue to be, successfully adapted from nature for use in separation and detection applications. It has been previously reported that the magnetophoretic mobility of labeled cells show a saturation type phenomenon as a function of the concentration of the free antibody-magnetic nanoparticle conjugate which is consistent with other reports of antibody-fluorophore binding. Starting with the standard antibody-antigen relationship, a model was developed which takes into consideration multi-valence interactions, and various attributes of flow cytometry (FCM) and cell tracking velocimetry (CTV) measurements to determine both the apparent dissociation constant and the antibody-binding capacity (ABC) of a cell. This model was then evaluated on peripheral blood lymphocytes (PBLs) labeled with anti CD3 antibodies conjugated to FITC, PE, or DM (magnetic nanoparticles). Reasonable agreements between the model and the experiments were obtained. In addition, estimates of the limitation of the number of magnetic nanoparticles that can bind to a cell as a result of steric hinderance was consistent with measured values of magnetophoretic mobility. Finally, a scale-up model was proposed and tested which predicts the amount of antibody conjugates needed to achieve a given level of saturation as the total number of cells reaches 10(10), the number of cells needed for certain clinical applications, such as T-cell depletions for mismatched bone marrow transplants.

Antibody Affinity↗

Decibel attenuation of pulsed electromagnetic field (PEMF) in blood and cortical bone determined experimentally and from the theory of ohmic losses.

We studied the PEMF power attenuation in tissues representative of clinical applications (blood and cortical bone) to determine the amount of power available for PEMF purported biological effects. The experimental system consisted of a pair of nearly circular, parallel and coaxial coils separated by a distance of one coil diameter. The power attenuation was measured using a small search coil connected to a digital oscilloscope. The coils were powered by a voltage switch operating at two different frequencies (3.8 and 63 kHz) producing bursts of pulses (numbering 21 and 1619) and triggered at two different frequencies (1.5 and 15 Hz, respectively). The tissue samples were placed inside the coils so as to expose them to either transverse electric field (at the center of coils) or the transverse magnetic field (at the coil wire). The cylindrical coil geometry yielded closed-form expressions for power attenuation based on magnetic diffusion equation and ohmic losses due to bulk tissue magnetic permeability and electrical conductivity. The measured power attenuation at these PEMF frequencies of not more than one decibel (1 dB) was well explained by the theory for the 3.8 kHz but less so for the 63 kHz frequency PEMF. The results provide important insights regarding physical mechanism of weak PEMF power dissipation in tissues.

Animals↗

Comparison of two immunomagnetic separation technologies to deplete T cells from human blood samples.

The objective of this study was to compare the performance of two immunomagnetic separation technologies to deplete T cells from buffy coats of human blood. Specifically, two versions of the commercial MACS(R) Technology: MiniMACS and SuperMACS, and a prototype, flow-through system, the QMS, were evaluated. Peripheral blood mononuclear leukocytes (PBL) were isolated from buffy coats and an immunomagnetic separation of CD3(+) cells was conducted using company and optimized labeling protocols. To mimic peripheral blood containing bone marrow purged hematopoietic stem cells, HSC, CD34 expressing-cells (KG1a) were spiked into PBL prior to T-cell depletion once optimized depletion conditions were determined. Once the labeling protocol was optimized, the MiniMACS system performed well by producing a highly enriched CD3(+) fraction, and a respectable level of depletion of T cells and recovery of KG1a cells in the depleted fraction; an average log(10) depletion of T cells of 2.88 +/- 0.17 and an average recovery of the KG1a cells of 60.8 +/- 5.94% (n = 14). The performance of the SuperMACS system was very similar with an average log(10) depletion of T cells of 2.89 +/- 0.22 and an average recovery of KG1a of 63.1 +/- 8.55% (n = 10). In contrast, the QMS system produced an average log(10) depletion of T cells of 3.98 +/- 0.33 (n = 16) with a corresponding average recovery of 57.9 +/- 16.6% of the spiked CD34+ cells. The aforementioned QMS performance values were obtained using sorting speeds ranging from 2.5 x 10(4) to 1.7 x 10(5) cells per second. It is suggested that the lack of a 100% recovery of the unlabeled KG1a cells is the result of a previously reported "drafting" phenomena which pulls unlabeled cells in the direction of the magnetically labeled cells thereby resulting in loss of the unlabeled cells.

Antigens, CD34↗

Continuous flow magnetic cell fractionation based on antigen expression level.

Cell separation is important in medical and biological research and plays an increasingly important role in clinical therapy and diagnostics, such as rare cancer cell detection in blood. The immunomagnetic labeling of cells with antibodies conjugated to magnetic nanospheres gives rise to a proportional relationship between the number of magnetic nanospheres attached to the cell and the cell surface marker number. This enables the potential fractionation of cell populations by magnetophoretic mobility (MM). We exploit this feature with our apparatus, the Dipole Magnet Flow Fractionator (DMFF), which consists of an isodynamic magnetic field, an orthogonally-oriented thin ribbon of cell suspension in continuous sheath flow, and ten outlet flows. From a sample containing a 1:1 mixture of immunomagnetically labeled (label+) and unlabeled (label-) cells, we achieved an increase in enrichment of the label+ cell fraction with increasing outlet numbers in the direction of the magnetic field gradient (up to 10-fold). The total recovery of the ten outlet fractions was 90.0+/-7.7%. The mean MM of label+ cells increased with increasing outlet number by up to a factor of 2.3. The postulated proportionality between the number of attached magnetic beads and the number of cell surface markers was validated by comparison of MM measured by cell tracking velocimetry (CTV) with cell florescence intensity measured by flow cytometry.

Antigens↗

Hemoglobin degradation in malaria-infected erythrocytes determined from live cell magnetophoresis.

During intra-erythrocytic development, malaria trophozoites digest hemoglobin, which leads to parasite growth and asexual replication while accumulating toxic heme. To avoid death, the parasite synthesizes insoluble hemozoin crystals in the digestive vacuole through polymerization of beta-hematin dimers. In the process, the heme is converted to a high-spin ferriheme whose magnetic properties were studied as early as 1936 by Pauling et al. Here, by magnetophoretic cell motion analysis, we provide evidence for a graduated increase of live cell magnetic susceptibility with developing blood-stage parasites, compatible with the increase in hemozoin content and the mechanism used by P. falciparum to avoid heme toxicity. The measured magnetophoretic mobility of the erythrocyte infected with a late-stage schizont form was m = 2.94 x 10(-6) mm3 s/kg, corresponding to the net volume magnetic susceptibility (relative to water) of Deltachi = 1.80 x 10(-6), significantly higher than that of the oxygenated erythrocyte (-0.18x10(-6)) but lower than that of the fully deoxygenated erythrocyte (3.33x10(-6)). The corresponding fraction of hemoglobin converted to hemozoin, calculated based on the known magnetic susceptibilities of hemoglobin heme and hemozoin ferriheme, was 0.50, in agreement with the published biochemical and crystallography data. Magnetophoretic analysis of live erythrocytes could become significant for antimalarial drug susceptibility and resistance determination.

Animals↗

Exposure of murine cells to pulsed electromagnetic fields rapidly activates the mTOR signaling pathway.

Murine pre-osteoblasts and fibroblast cell lines were used to determine the effect of pulsed electromagnetic field (PEMF) exposure on the production of autocrine growth factors and the activation of early signal transduction pathways. Exposure of pre-osteoblast cells to PEMF minimally increased the amount of secreted TGF-beta after 1 day, but had no significant effects thereafter. PEMF exposure of pre-osteoblast cells also had no effect on the amount of prostaglandin E(2) in the conditioned medium. Exposure of both pre-osteoblasts and fibroblasts to PEMF rapidly activated the mTOR signaling pathway, as evidenced by increased phosphorylation of mTOR, p70 S6 kinase, and the ribosomal protein S6. Inhibition of PI3-kinase activity with the chemical inhibitor LY294002 blocked PEMF-dependent activation of mTOR in both the pre-osteoblast and fibroblast cell lines. These findings suggest that PEMF exposure might function in a manner analogous to soluble growth factors by activating a unique set of signaling pathways, inclusive of the PI-3 kinase/mTOR pathway.

Animals↗

Exposure of mouse preosteoblasts to pulsed electromagnetic fields reduces the amount of mature, type I collagen in the extracellular matrix.

We tested the hypothesis that exposure of a mouse preosteoblast cell line to pulsed electromagnetic fields (PEMF) would affect components of the extracellular matrix. We report that exposure of MC3T3-E1 cells to a single PEMF waveform significantly reduced the amount of mature, alpha1(I) collagen in the extracellular matrix (ECM) and the conditioned medium, without affecting the amount of total ECM protein. This decrease was not due to changes in the steady-state level of Col1A1 mRNA or to degradation of mature collagen. We then tested the effect of three distinct PEMF waveforms, two orthogonal coil orientations, and two waveform amplitude levels on the amount of alpha1(I) collagen in the conditioned medium. A sequence of factorial ANOVAs and stepwise regression modeling revealed that the period (duration) of the individual pulses accounted for a significant proportion of the variance associated with the amount of alpha1(I) collagen in the conditioned medium. The total variance accounted for, however, was small (R(2)=0.155, p<0.001 and R(2)=0.172, p<0.001, in the horizontal and vertical orientations, respectively). The positive and negative regression coefficients for the coil orientations revealed that the influence of pulse period was significantly different for the orthogonal coil orientations (p<0.001). The findings imply that the dominant influence of PEMF on the amount of mature, alpha1(I) collagen in the ECM is related to variables other than those expressed in the time-amplitude domain. The results provide objective direction toward identifying waveform characteristics that contribute to the observed between-waveform differences with regard to collagen. Advances in this area may lead toward improving waveforms and waveform delivery protocols.

Animals↗

Diagnosis of malaria by magnetic deposition microscopy.

Although malaria contributes to a significant public health burden, malaria diagnosis relies heavily on either non-specific clinical symptoms or blood smear microscopy methods developed in the 1930s. These approaches severely misrepresent the number of infected individuals and the reservoir of parasites in malaria-endemic communities and undermine efforts to control disease. Limitations of conventional microscopy-based diagnosis center on time required to examine slides, time required to attain expertise sufficient to diagnose infection accurately, and attrition from the limited number of existing malaria microscopy experts. Earlier studies described magnetic properties of Plasmodium falciparum but did not refine methods to diagnosis infection by all four human malaria parasite species. Here, following specific technical procedures, we show that it is possible to concentrate all four human malaria parasite species, at least 40-fold, on microscope slides using very inexpensive magnets through an approach termed magnetic deposition microscopy. This approach delivered greater sensitivity than a thick smear preparation while maintaining the clarity of a thin smear to simplify species-specific diagnosis. Because the magnetic force necessary to concentrate parasites on the slide is focused at a precise position relative to the magnet surface, it is possible to examine a specific region of the slide for parasitized cells and avoid the time-consuming process of scanning the entire slide surface. These results provide insight regarding new strategies for performing malaria blood smear microscopy.

Animals↗

Cell sorting by one gravity SPLITT fractionation.

The need for innovative separative techniques suitable for the fractionation of biomaterials prompted this investigation into the performance of the gravitational split-flow thin channel (G-SPLITT) system as a cell sorter. The rigorous mathematical description of the separation mechanism allows achievement of fast separation of several million myeloma cells from healthy splenocytes using flow conditions calculated from theory. Separation in G-SPLITT is based on differences in sedimentation rate. For accurate prediction of the optimal working conditions, this parameter was directly measured by cell tracking velocimetry rather than relying on a measure of diameter (by Multisizer) and an assumed density for each cell population. We also discuss the influence of different flow conditions on the effectiveness of separation.

Cell Separation↗

Establishment and implications of a characterization method for magnetic nanoparticle using cell tracking velocimetry and magnetic susceptibility modified solutions.

Magnetic micro and nanoparticles conjugated to affinity labels have become a significant, commercial reagent. It has been demonstrated that the performance of cell separation systems using magnetic labels is a function of the magnitude of the magnetic force that can be generated through labeling. This magnetic force is proportional to the number of magnetic particles bound to the cell, the magnetic energy gradient, and the particle-field interaction parameter. This particle-field interaction parameter, which is the product of the relative volumetric, magnetic susceptibility and the volume of the micro or nanoparticle, is a fundamental parameter which can be used to characterize the magnetic particles. An experimental technique is presented which measures the volumetric magnetic susceptibility of particles through the use of susceptibility modified solutions and an experimental instrument, Cell Tracking Velocimetry, CTV. Experimental studies were conducted on polystyrene microspheres alone and those bound to four different magnetic nanoparticles. The experimentally determined values of the magnetic susceptibility of the polystyrene microspheres are consistent with values found from literature. Consequently, magnetic susceptibility measurements of these polystyrene microspheres bound with the magnetic nanoparticles combined with particle size measurements using commercial dynamic light scattering instrument allowed estimates of the particle-field interaction parameter to be made for four commercial, magnetic nanoparticles. The value found for MACS beads is close to what is reported from an independent study. The values for MACS beads and Imag beads are found to agree with what is observed from experiments. Finally, an experimental demonstration of the impact that differences in this field interaction parameter has on the labeling of human lymphocytes is presented.

Cell Movement↗

Cell tracking velocimetry as a tool for defining saturation binding of magnetically conjugated antibodies.

BACKGROUND: Continuous flow immunomagnetic separation is an attractive alternative to current batch mode immunomagnetic separation methods because it is capable of high sorting speeds at mild cell conditions, and grants the operator better control of separation process. The control of the separation is dependent on knowledge of the amount of magnetic label attached to the cell (magnetic labeling intensity), however. Determination of the magnetic labeling is accomplished by measuring cell magnetophoretic mobility using a newly developed technique of Cell Tracking Velocimetry (CTV). METHODS: Flow cytometry was used to define the antibody binding characteristics of a fluorescently tagged primary antibody. Subsequently, CTV was used to measure antibody-binding characteristics of a magnetically tagged secondary antibody. RESULTS: The results of this study show that CTV is capable of providing valuable information concerning the cell labeling by magnetically tagged antibodies. It was demonstrated that the magnetically conjugated antibody binding curve exhibits the same exponential increase to saturation characteristics as that seen with the fluorescently tagged antibody. Further, it was shown that the intensity of the secondary magnetic labeling is directly proportional to the intensity of the primary fluorescent label. CONCLUSIONS: CTV is an accurate tool for evaluation of magnetically conjugated antibodies. The ability to determine the intensity of magnetic labeling is necessary for the development of continuous flow immunomagnetic separations based on cell magnetophoresis.

Antibodies, Monoclonal↗

Pulsed electromagnetic field treatments enhance the healing of fibular osteotomies.

This study tested the hypothesis that pulsed electromagnetic field (PEMF) treatments augment and accelerate the healing of bone trauma. It utilized micro-computed tomography imaging of live rats that had received bilateral 0.2 mm fibular osteotomies (approximately 0.5% acute bone loss) as a means to assess the in vivo rate dynamics of hard callus formation and overall callus volume. Starting 5 days post-surgery, osteotomized right hind limbs were exposed 3 h daily to Physio-Stim PEMF, 7 days a week for up to 5 weeks of treatment. The contralateral hind limbs served as sham-treated, within-animal internal controls. Although both PEMF- and sham-treatment groups exhibited similar onset of hard callus at approximately 9 days after surgery, a 2-fold faster rate of hard callus formation was observed thereafter in PEMF-treated limbs, yielding a 2-fold increase in callus volume by 13-20 days after surgery. The quantity of the new woven bone tissue within the osteotomy sites was significantly better in PEMF-treated versus sham-treated fibulae as assessed via hard tissue histology. The apparent modulus of each callus was assessed via a cantilever bend test and indicated a 2-fold increase in callus stiffness in the PEMF-treated over sham-treated fibulae. PEMF-treated fibulae exhibited an apparent modulus at the end of 5-weeks that was approximately 80% that of unoperated fibulae. Overall, these data indicate that Physio-Stim PEMF treatment improved osteotomy repair. These beneficial effects on bone healing were not observed when a different PEMF waveform, Osteo-Stim, was used. This latter observation demonstrates the specificity in the relationship between waveform characteristics and biological outcomes.

Animals↗

Magnetic cell sorting.

Antibodies reacting to specific cell surface markers can be bound to magnetic beads and used to specifically capture cells exhibiting the marker. This approach allows the selective enrichment of specific cell subpopulations and as the methods are amenable to use in blood, tissue fluids and culture medium living cells can be recovered that can subsequently be subcultured. Negative cell separation can also be used where undesirable cell types are tagged using magnetic beads and removed from the desirable cell population.

Antibodies↗

In vivo longitudinal assessment of bone resorption in a fibular osteotomy model using micro-computed tomography.

Longitudinal in vivo micro-computerized tomography (CT) imaging was used to monitor bone resorption in a rat fibula osteotomy model. Quantitative image post-processing techniques were developed for spatially aligning the longitudinal data sets. Nominal length and bone volume in the proximal and distal segments of the fibula after the osteotomy were measured, and quantitative comparisons of bone loss over a 13-week period post-surgery were made in five individual rats. A significant decrease in nominal length and bone volume of the distal segment was observed 13 weeks post surgery. A significant decrease in bone volume was also observed in the proximal segment. However, no change in nominal length was observed for the proximal segment of the fibula. This study illustrates the power of this non-invasive technology to measure in vivo small changes in bone length and volume using just a small cohort of animals.

Animals↗

Control of magnetophoretic mobility by susceptibility-modified solutions as evaluated by cell tracking velocimetry and continuous magnetic sorting.

With the analytical expression for the magnetophoretic mobility of an ideal, linearly polarizable sphere undergoing creeping motion in viscous medium, we have shown that both attractive and repulsive motions are possible in the magnetic field. We have validated theoretical predictions using magnetic monodisperse microspheres of 5.2-microm diameter and nonmagnetic polystyrene microspheres of 6.99-microm diameter suspended in solutions of paramagnetic ions. The microsphere magnetophoretic mobility was measured using a modified particle tracking velocimetry system, developed in-house and called a cell tracking velocimeter. The product of measured mobility and viscosity agrees well with the theoretical prediction, differing only by approximately 11%. Further, a 26% increase in resolution between magnetic and nonmagnetic particle distributions was evaluated when paramagnetic ion carrier was used instead of water. Continuous particle sorting based on differences in magnetophoretic mobility was performed with another device developed by us, the quadrupole magnetic flow sorter (QMS). In the QMS, the introduction of paramagnetic ions into the carrier was effective in suppressing nonspecific crossover (i.e., the transport of low-mobility particles into the magnetic particle fraction) in particles and in biologically relevant red blood cells and thus showed promise as a means of increasing the purity of the magnetic separation.

Journal Article↗

Enrichment of rare cancer cells through depletion of normal cells using density and flow-through, immunomagnetic cell separation.

OBJECTIVE: To develop a reliable technique to enrich for rare cells in blood suspensions using only negative selection steps including a flow-through immunomagnetic cell separations system and by optimizing variables normally encountered during such enrichment processes. METHODS: A human breast cancer cell line was cultivated and spiked at a ratio of 1 cancer cell to 10(5) total leukocytes in buffy coat or 1 cancer cell to 10(8) total cells in whole blood samples. The final, optimized process consisted of: a red cell lysis step, immunomagnetically staining leukocytes with an anti-CD45 PE, anti- MACS sandwich, immunomagnetic sorting using a flow-through system (QMS), and a final cell analysis step using either an automated cell counter, filtration, and visual counting or a cytospin analysis. RESULTS: The final, optimized process produced a final enrichment of the rare cancer cells of 5.17 log(10) and an average, final recovery of 46%. It should be noted that a negative depletion protocol was used (i.e., no labeling of the rare cancer cells was used). CONCLUSIONS: To the authors' knowledge, no examples in the literature exist of a 5.17 log(10) enrichment of cancer cells in human blood using a negative depletion protocol. The closest example is a 4 log(10) enrichment in which two positive magnetic cell separation steps were used (none were used in this study). Ongoing studies are investigating further modifications of the precommercial, prototype flow-through immunmagnetic separation system to increase both the enrichment and recovery rate. However, even at current performance levels, the presented process could significantly improve visual and molecular analysis of rare cells in blood.

Antibodies, Monoclonal↗