PubMed Health⌕ Search

Biomedical subjects

Madhu Prakash Chatrathi

Publications and source records attributed to Madhu Prakash Chatrathi.

14 recordsLinked to original sources

Sandwich electrochemical immunoassay for the detection of Staphylococcal enterotoxin B based on immobilized thiolated antibodies.

A new approach for the sensitive detection of Staphylococcal enterotoxin B (SEB) is presented based upon an electrochemical enzymatic immunoassay that utilizes thiolated antibodies immobilized on a gold surface. This method relies on the use of amine- or sulfhydryl-reactive heterobifunctional cross-linkers for the introduction of 2-pyridyl-disulfide groups to the antibody. The disulfide-containing linkages are subsequently cleaved with a suitable reducing agent, such as dithiothreitol (DTT), and the thiolated antibody-gold bond is covalently formed on a gold working electrode. Various cross-linking agents for immobilization of the capture antibody onto the gold electrode were investigated and compared. Factors influencing the thiolation and immobilization were investigated and optimized. The feasibility of such antibody immobilization and the subsequent sandwich enzyme immunoassay is demonstrated for the sensitive detection of SEB. The detection limit estimated from a representative dose-response curve is 1 ng/mL, corresponding to 5 pg in a 5-microL sample. Coupling the specificity of immunoassays with the sensitivity and low detection limits of electrochemical detection shows real promise for future sensing technology in enabling the development of single-use disposable devices.

Antibodies↗

Microchip capillary electrophoresis with amperometric detection for rapid separation and detection of seleno amino acids.

This article describes an effective microchip capillary-electrophoresis protocol for rapid and effective measurements of food-related seleno amino acids, including Se-methionine (Se-Met), Se-ethionine (Se-Eth), Se-methyl cysteine (Se-Cys), utilizing o-phtaldialdeyde/2-mercaptoethanol (OPA/2-ME) derivatization. Relevant parameters of the chip separation and amperometric detection are examined and optimized using a response surface methodology (RSM). Under optimum conditions, the analytes could be separated and detected in a 30 mM borate buffer (pH 9.3, with 28 mM sodium dodecul sulfate) within 300 s using a separation voltage of 2000V and a detection voltage of +0.9 V. Linear calibration plots are observed for micromolar concentrations of the Se-amino acid compounds. The negligible sample volumes used in the microchip procedure obviates surface fouling common to amperometric measurements of selenoamino-acid compounds. The new microchip protocol offers great promise for a wide range of food applications requiring fast measurements and negligible sample consumption.

Amino Acids↗

Bulk modification of polymeric microfluidic devices.

The surface properties of microfluidic devices play an important role in their flow behavior. We report here on an effective control of the surface chemistry and performance of polymeric microchips through a bulk modification route during the fabrication process. The new protocol is based on modification of the bulk microchip material by tailored copolymerization of monomers during atmospheric-pressure molding. A judicious addition of a modifier to the primary monomer solution thus imparts attractive properties to the plastic microchip substrate, including significant enhancement and/or modulation of the EOF (with flow velocities comparable to those of glass), a strong pH sensitivity and high stability. Carboxy, sulfo, and amino moieties have thus been introduced (through the incorporation of methylacrylic acid, 2-sulfoethyl-methacrylate and 2-aminoethyl-methacrylate monomers, respectively). A strong increase in the electroosmotic pumping compared to the native poly(methylmethacrylate)(PMMA) microchip (ca. electroosmotic mobility increases from 2.12 to 4.30 x 10(-4) cm(2) V(-1) s(-1)) is observed using a 6% methylacrylate (MAA) modified PMMA microchip. A 3% aminoethyl modified PMMA microchip exhibits a reversal of the electroosmotic mobility (for example, -5.6 x 10(-4) cm(2) V(-1) s(-1) at pH 3.0). The effects of the modifier loading and the pH on the EOF have been investigated for the MAA-modified PMMA chips. The bulk-modified devices exhibit reproducible and stable EOF behavior. The one step fabrication/modification protocol should further facilitate the widespread production of high-performance plastic microchip devices.

Journal Article↗

Microchip capillary electrophoresis with amperometric detection for rapid separation and detection of phenolic acids.

A microchip capillary-electrophoresis protocol for rapid and effective measurements of food-related phenolic acids (including chlorogenic, gentisic, ferulic, and vanillic acids) is described. Relevant parameters of the chip separation and amperometric detection are examined and optimized. Under optimum conditions, the analytes could be separated and detected in a 15 mM borate buffer (pH 9.5, with 10% of methanol) within 300 s using a separation voltage of 2000 V and a detection voltage of +1.0 V. Linear calibration plots are observed for micromolar concentrations of the phenolic acid compounds. The negligible sample volumes used in the microchip procedure obviates surface fouling common to amperometric measurements of phenolic compounds. The new microchip protocol offers great promise for a wide range of food applications requiring fast measurements and negligible sample consumption. An application on a commercial red wine was performed with minimal sample preparation and promising results.

Buffers↗

Microchip capillary electrophoresis with electrochemical detection of thiol-containing degradation products of V-type nerve agents.

A microchip protocol for the capillary electrophoresis separation and electrochemical detection of thiol-containing degradation products of V-type nerve agents is described. The microchip assay relies on the derivatization reaction of 2-(dimethylamino)ethanethiol (DMAET), 2-(diethylamino)ethanethiol (DEAET), and 2-mercaptoethanol (ME) with o-phthaldialdehyde in the presence of the amino acid valine along with amperometric monitoring of the isoindole derivatives. Both off-chip and on-chip derivatization reactions have led to highly sensitive and rapid detection of the thiol degradation products. Various parameters influencing the derivatization, separation, and detection processes were examined and optimized. These include the amino acid co-reagent, reagent-mixing ratio, reaction time, injection time, separation voltage, and detection potential. The chip microsystem offers a rapid (<4 min) simultaneous detection of micromolar concentrations of DMAET, DEAET, and ME. Linear calibration plots were observed for the V-type nerve agent thiol degradation products, along with good stability and reproducibility (RSD < 8.0%). Detection limits of 5 and 8 microM were obtained for the off-chip reaction of DMAET and DEAET, respectively, following a 2-s injection. The suitability for assays of environmental matrixes was demonstrated for the determination of DMAET and DEAET in untreated tap and river water samples. The favorable analytical performance makes the new microfluidic device attractive for addressing the needs of various security scenarios.

Biodegradation, Environmental↗

Carbon-nanotube/copper composite electrodes for capillary electrophoresis microchip detection of carbohydrates.

The preparation of carbon nanotube (CNT)/copper composite electrodes, based on co-mixing CNT and Cu powders within mineral oil, is described. The new composite electrode is used for improved amperometric detection of carbohydrates following their capillary electrophoresis (CE) microchip separations. The CNT/Cu composite electrode detector displays enhanced sensitivity compared to detectors based on copper or CNT alone. The marked catalytic action of the CNT/Cu composite material permits effective low potential (+0.5 V vs. Ag/AgCl) amperometric detection, and is coupled to the renewability, bulk modification and versatility advantages of composite electrodes. The CNT/Cu composite surface also leads to a greater resistance to surface fouling compared to that observed at the copper electrode. Factors affecting the electrocatalytic activity and the CE microchip detection are examined and optimized. The CNT/Cu composite electrode is also shown to be useful for the detection of amino acids as indicated from preliminary results. While the present work has focused on the enhanced CE microchip detection of carbohydrates and amino acids, the CNT/metal-composite electrode route should benefit the detection of other important groups of analytes.

Amino Acids↗

Fabrication of poly(methyl methacrylate) microfluidic chips by atmospheric molding.

A greatly simplified method for fabricating poly(methyl methacrylate) (PMMA) separation microchips is introduced. The new protocol relies on UV-initiated polymerization of the monomer solution in an open mold under ambient pressure. Silicon microstructures are transferred to the polymer substrate by molding a methyl methacrylate solution in a sandwich (silicon master/Teflon spacer/glass plate) mold. The chips are subsequently assembled by thermal sealing of the channel and cover plates. The new fabrication method obviates the need for specialized replication equipment and reduces the complexity of prototyping and manufacturing. Variables of the fabrication process were assessed and optimized. The new method compares favorably with common fabrication techniques, yielding high-quality devices with well-defined channel and injection-cross structures, and highly smoothed surfaces. Nearly 100 PMMA chips were replicated using a single silicon master, with high chip-to-chip reproducibility (relative standard deviations of 1.5 and 4.7% for the widths and depths of the replicated channels, respectively). The relatively high EOF value of the new chips (2.12 x 10(-4) cm(2) x V(-1) x s(-1)) indicates that the UV polymerization process increases the surface charge and hence enhances the fluidic transport. The attractive performance of the new CE microchips has been demonstrated in connection with end-column amperometric and contactless-conductivity detection schemes. While the new approach is demonstrated in connection with PMMA microchips, it could be applied to other materials that undergo light-initiated polymerization. The new approach brings significant simplification of the process of fabricating PMMA devices and should lead to a widespread low-cost production of high-quality separation microchips.

Journal Article↗

Capillary electrophoresis microchip with a carbon nanotube-modified electrochemical detector.

Significant improvements in the performance of a capillary electrophoresis (CE) microchip with an electrochemical detector are observed using a carbon nanotube (CNT)-modified working electrode. The CNT-modified electrode allows CE amperometric detection at significantly lower operating potentials and yields substantially enhanced signal-to-noise characteristics. The electrocatalytic detection is coupled to resistance to surface fouling and hence enhanced stability. Such advantages are illustrated in connection with several classes of hydrazine, phenol, purine, and amino acid compounds. Substantial minimization of surface fouling effects has been demonstrated in connection with the monitoring of phenol and tyrosine. Factors affecting the performance of the new CNT detector were assessed and optimized. CNTs from different sources are evaluated, and the effect of an anodic pretreatment is explored. The broad and significant catalytic activity exhibited by CNT-based CE detectors indicates great promise for a wide range of bioanalytical and environmental applications.

Journal Article↗

On-chip integration of enzyme and immunoassays: simultaneous measurements of insulin and glucose.

A microfluidic device coupling immunological and enzymatic assays within a single microchannel has been developed for simultaneous measurements of insulin and glucose. Such a dual-mode (enzyme/immuno) protocol involves precolumn reactions of insulin and glucose with the enzyme-labeled anti-human insulin and glucose-dehydrogenase/NAD+, respectively, followed by the electrophoretic separation of the free antibody, antibody-antigen complex, and the NADH product of the enzymatic reaction. The separation is followed by a postcolumn reaction of the alkaline-phosphatase tracer with the p-NPP substrate and a downstream amperometric detection of the p-nitrophenol and NADH products. Despite the huge concentration difference [millimolar (glucose) and nanomolar (insulin)] and the use of different assay principles, the new biochip responds independently to the corresponding target analytes, with linear dynamic ranges over their clinically relevant ranges. Complete assays, carried out within less than 4 min, lead to good precision (RSD 0.36%) for the insulin/glucose ratio. The resulting biochip allows simultaneous testing for insulin and glucose to be performed more rapidly, easily, and economically, and hence it holds great promise for improved management of diabetes.

Antibodies↗

Microchip capillary electrophoresis coupled with a boron-doped diamond electrode-based electrochemical detector.

The attractive behavior and advantages of a diamond electrode detector for a micromachined capillary electrophoresis (CE) system are discussed. A chemically vapor-deposited boron-doped diamond (BDD) film band (0.3 x 6.0 mm) electrode is used for end-column amperomettic detection. The favorable performance of the diamond electrode microchip detector is indicated from comparison to a commonly used thick-film carbon detector. The diamond electrode offers enhanced sensitivity, lower noise levels, and sharper peaks for several groups of important anaytes (nitroaromatic explosives, organophosphate nerve agents, phenols). The favorable signal-to-background characteristics of the BDD-based CE detector are coupled with a greatly improved resistance to surface fouling and greater isolation from high separation voltages. The enhanced stability is indicated from a RSD of 0.8% for 60 repetitive measurements of 5 ppm 2,4,6-trinitrotoluene (vs RSD of 10.8% at the thick-film carbon electrode). A highly linear response is obtained for the explosives 1,3-dinitrobenzene and 2,4-dinitrotoluene over the 200-1,400 ppb range, with detection limits of 70 and 110 ppb, respectively. Factors influencing the performance of the BDD detector are assessed and optimized. The attractive properties of BDD make it very promising material for electrochemical detection in CE microchip systems and other micromachined flow analyzers.

Air Pollutants, Occupational↗

Microfabricated electrophoresis chip for bioassay of renal markers.

A novel capillary electrophoresis chip-based detection system for simultaneous measurements of the renal markers creatine, creatinine, p-aminohippuric acid, and uric acid is described. Fluid control is used for mixing the sample with the enzymes creatininase (CA), creatinase (CI), and sarcosine oxidase (SOx) and for separating the neutral hydrogen peroxide end product from the anionic p-aminohippuric and urate species. The 'total' (creatinine and creatine) signal was measured with the running buffer containing all three enzymes, while the creatine signal alone was recorded by mixing the sample with the CI-SOx solution. Creatinine concentrations are measured by comparing the response in the presence and absence of CA. The peroxide product and the oxidizable p-aminohippuric and uric acids are detected electrochemically at a downstream gold-coated thick-film amperometric detector. The four renal markers are readily measured within 5 min, while creatinine/creatine within less than 2 min. Factors influencing the performance, including the level of three enzymes, separation voltage, and detection potential, are optimized. Applicability to urine samples is demonstrated. Such a multianalyte microchip detection device would allow renal function testing to be performed more rapidly, easily, and economically in the point-of-care setting.

Biomarkers↗

Single-channel microchip for fast screening and detailed identification of nitroaromatic explosives or organophosphate nerve agents.

A single-channel chip-based analytical microsystem that allows rapid flow injection measurements of the total content of organic explosive or nerve agent compounds, as well as detailed micellar chromatographic identification of the individual ones, is described. The protocol involves repetitive rapid flow injection (screening) assays--to provide a timely warning and alarm--and switching to the separation (fingerprint identification) mode only when harmful compounds are detected. While micellar electrokinetic chromatography, in the presence of sodium dodecyl sulfate (SDS), is used for separating the neutral nitroaromatic explosive and nerve agent compounds, an operation without SDS leads to high-speed measurements of the "total" explosives or nerve agent content. Switching between the "flow injection" and "separation" modes is accomplished by rapidly exchanging the SDS-free and SDS-containing buffers in the separation channel. Amperometric detection was used for monitoring the separation. Key factors influencing the sample throughput, resolution, and sensitivity have been assessed and optimized. Assays rates of about 360 and 30/h can thus be realized for the "total" screening and "individual" measurements, respectively. Ultimately, such development will lead to the creation of a field-deployable microanalyzer and will enable transporting the forensic laboratory to the sample source.

Chemical Warfare Agents↗

Towards disposable lab-on-a-chip: poly(methylmethacrylate) microchip electrophoresis device with electrochemical detection.

A fully disposable microanalytical device based on combination of poly(methylmethacrylate) (PMMA) capillary electrophoresis microchips and thick-film electrochemical detector strips is described. Variables influencing the separation efficiency and amperometric response, including separation voltage or detection potential are assessed and optimized. The versatility, simplicity and low-cost advantages of the new design are coupled to an attractive analytical performance, with good precision (relative standard deviation RSD = 1.68% for n = 10). Applicability for assays of mixtures of hydrazine, phenolic compounds, and catecholamines is demonstrated. Such coupling of low-cost PMMA-based microchips with thick-film electrochemical detectors holds great promise for mass production of single-use micrototal analytical systems.

Catecholamines↗

Microchip-based amperometric immunoassays using redox tracers.

A new chip-based electrochemical immunoassay protocol, based on the use of a ferrocene redox label, is described. Two reaction formats, based on direct (noncompetitive) and competitive modes of operation, were employed for illustrating the use of redox tracers in chip-based electrochemical immunoassays. The direct assay consisted of mixing the ferrocene-tagged antibody and the antigen analyte, a rapid electrophoretic separation of labeled free antibody and the labeled antigen/antibody complex, and a downstream anodic detection of the ferrocene tracer at gold-plated carbon screen-printed electrode detector. The competitive assay integrates precolumn reactions of the labeled antigen and the target antigen with the antibody with electrophoretic separation of the free and bound labeled antigens, along with amperometric detection of the redox tag. An internal standard has been used to normalize the peak area for the construction of calibration plots. Fundamental operating variables are examined and optimized. The use of a redox tracer offers the advantages of simplified protocol, wider linear range, higher stability, and higher separation efficiency compared to an analogous use of enzyme tags. The direct mouse-immunoglobulin G (IgG) assay and the competitive 3,3',5-triiodo-L-thyronine (T(3)) one were accomplished within less than 150 and 130 s (with field strengths of 256 and 192 V/cm), and offer minimum detectable concentrations of 2.5 x 10(-12) and 1 x1 0(-6) g/mL, respectively. Such use of redox labels for chip-based amperometric immunoassay protocols offers considerable promise for decentralized clinical or environmental testing.

Antigen-Antibody Complex↗