Determination of organophosphate esters in air samples by dynamic sonication-assisted solvent extraction coupled on-line with large-volume injection gas chromatography utilizing a programmed-temperature vaporizer.

An on-line method for the determination of airborne organophosphate esters based on dynamic sonication-assisted solvent extraction and large-volume injection (LVI) gas chromatography with nitrogen-phosphorous detection is introduced. The LVI is performed with a programmed-temperature vaporizer. The entire extracted fraction of 800 microl (hexane-methyl-tert.-butyl ether, 7:3, v/v) is introduced directly into the GC system without any clean-up step following extraction. The extraction and analysis step were completed in less than 15 min. The limit of detection of the investigated organophosphate esters was established to be in the range of 5-32 pg/filter. The correlation coefficients (r2) were investigated in the linear range study of the entire system and established to be approximately 0.9900 for all the investigated organophosphates esters. Applications of the method was demonstrated with the extraction of air samples collected onto glass fiber filters from different indoor environments. Six organophosphate esters were found at the levels 0.4-138 ng/m3.

Air↗

Dynamic microwave-assisted extraction coupled on-line with solid-phase extraction and large-volume injection gas chromatography: determination of organophosphate esters in air samples.

An on-line method was developed for the extraction, cleanup, and analysis of airborne organophosphate esters collected on glass fiber filters. The extraction and cleanup step was performed by conducting the dynamic microwave-assisted extraction (DMAE) coupled to solid-phase extraction (SPE). This system was further connected to include large-volume injection gas chromatography. The Injection interface was a programmable temperature vaporizer. The system performance test was investigated using spiked glass fiber filters. The DMAE-SPE recovery of the organophosphate esters was found to be greater than 97%. The repeatability of the uncorrected peak areas and the retention times was determined to be 4.2-8.0 and 0.03% relative standard deviation, respectively, and limits of detection were in the range 61-186.2 pg/m3. The method was tested in a newly restored office, in which several of the targeted organophosphate esters were detected. The total sampling and analysis time was less than 1.5 h.

Air Pollutants↗

Dynamic microwave-assisted extraction coupled on-line with solid-phase extraction: determination of polycyclic aromatic hydrocarbons in sediment and soil.

This paper describes a new extraction tool for the determination of polycyclic aromatic hydrocarbons (PAHs) in soil and sediment samples, using dynamic microwave-assisted extraction combined with solid-phase extraction (DMAE-SPE). The critical variables for DMAE-SPE are investigated and optimized in an experimental design. The technique proved to be fast, accurate and able to yield quantitative extraction of PAHs from naturally contaminated sediment and soil samples. The set-up is fully automated and features monitored extraction, which facilitates rapid optimization of the method. In addition, only small quantities of solvent and sample are required.

Chromatography, Gas↗

Dynamic sonication-assisted solvent extraction of organophosphate esters in air samples.

A new system for extracting solid samples based on dynamic sonication-assisted solvent extraction (DSASE) is described. The technique is highly efficient with respect to both time and solvent consumption. In tests reported here, organophosphate esters were extracted from air sampling filters in 3 min with an extraction volume of 600 microL of solvent. Furthermore, it was possible to replace a previously used chlorinated solvent with a halogen-free solvent mixture. The sample was placed in a cartridge through which fresh solvent was pumped continuously. A restrictor connected to the outlet of the cartridge allowed the system to be used at a temperature of 70 degrees C without reaching the boiling point of the solvent. Both spiked and non-spiked native samples were used for the evaluation, which clearly revealed a stronger analyte-matrix interaction in native samples. The DSASE technique was shown to recover larger amounts of organophosphate esters from native samples, compared to a static method. DSASE was applied to air samples collected in a lecture hall and from above a computer monitor.

Air↗