PubMed Health⌕ Search

Biomedical subjects

Magnus Wetterhall

Publications and source records attributed to Magnus Wetterhall.

10 recordsLinked to original sources

Capillary electrophoresis coupled to mass spectrometry from a polymer modified poly(dimethylsiloxane) microchip with an integrated graphite electrospray tip.

Hybrid capillary-poly(dimethysiloxane)(PDMS) microchips with integrated electrospray ionization (ESI) tips were directly fabricated by casting PDMS in a mould. The shapes of the emitter tips were drilled into the mould, which produced highly reproducible three-dimensional tips. Due to the fabrication method of the microfluidic devices, no sealing was necessary and it was possible to produce a perfect channel modified by PolyE-323, an aliphatic polyamine coating agent. A variety of different coating procedures were also evaluated for the outside of the emitter tip. Dusting graphite on a thin unpolymerised PDMS layer followed by polymerisation was proven to be the most suitable procedure. The emitter tips showed excellent electrochemical properties and durabilities. The coating of the emitter was eventually passivated, but not lost, and could be regenerated by electrochemical means. The excellent electrochemical stability was further confirmed in long term electrospray experiments, in which the emitter sprayed continuously for more than 180 h. The PolyE-323 was found suitable for systems that integrate rigid fused silica and soft PDMS technology, since it simply could be applied successfully to both materials. The spray stability was confirmed from the recording of a total ion chromatogram in which the electrospray current exhibited a relative standard deviation of 3.9% for a 30 min run. CE-ESI-MS separations of peptides were carried out within 2 min using the hybrid PDMS chip resulting in similar efficiencies as for fused silica capillaries of the same length and thus with no measurable band broadening effects, originating from the PDMS emitter.

Electrophoresis, Capillary↗

Comparison between different sheathless electrospray emitter configurations regarding the performance of nanoscale liquid chromatography-time-of-flight mass spectrometry analysis.

Four different sheathless electrospray ionization (ESI) configurations were investigated for a nano liquid chromatography (LC) system. The studied configurations were: a column with an integrated emitter, with the ESI potential applied before or after the column, and a column with separate emitter, with the ESI voltage applied at a union before the emitter or at the emitter tip. The results indicates that the efficiency of the LC system is rather independent of the configuration when using 95 microm i.d. columns, acetic mobile phase and standard peptides as a sample. Introduction of post column dead volume seems not to be a critical issue at least with flow rates down to 600 nl/min.

Nanotechnology↗

Monomer surface modifications for rapid peptide analysis by capillary electrophoresis and capillary electrochromatography coupled to electrospray ionization-mass spectrometry.

In this study, positively charged alkylaminosilyl monomers were used to modify the inner surface of fused silica capillaries, which subsequently were employed in capillary electrophoresis (CE) and capillary electrochromatography (CEC). The obtained surfaces yield a reversed electroosmotic flow (EOF) and have varying carbon chain lengths, that interact with the analytes and give chromatographic retention. The coating procedure is very simple and fast. The performance of the modified capillaries was evaluated regarding pH influence on EOF and chromatographic interactions. The experiments were conducted with UV and mass spectrometry (MS) and applied to the separation of various neuropeptides. The derivatized surfaces showed a linear (R(2) approximately 0.99) pH dependence with isoelectric points (pI) at 8.6-8.8. Rapid separations of peptide standards and a protein digest with efficiencies as high as 5 x 10(5) plates/m were performed.

Chromatography↗

A polyamine coating for enhanced capillary electrophoresis-electrospray ionization-mass spectrometry of proteins and peptides.

A procedure for enhanced capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) of proteins is presented. The use of a newly presented capillary coating, PolyE-323, provided fast separations of typically a few minutes with high efficiency, good deactivation, and no bleeding into the mass spectrometer. Capillaries coated with PolyE-323 showed high stability over a range of pH 2-10, and tolerance towards methanol and acetonitrile, two modifiers commonly used in CE-ESI-MS. Due to the speed and simplicity of the coating procedure, the polymeric surface could, if necessary, easily be regenerated. This capability is especially valuable when working with samples of complex matrix, where a capillary surface cleaning step might be desired in order to eliminate possible memory effects. The potential of PolyE-323-coated capillaries in bioanalysis using CE-ESI-MS was demonstrated by analyzing peptides and proteins up to 66 kDa using time of flight (TOF)-MS. Due to the stable, anodal electroosmotic flow generated by the coating, the use of a sheathless ESI interface was enabled, demonstrated in peptide analysis with attomole sensitivity. The fast on-line CE-ESI-TOF system using PolyE-323-coated capillaries provided efficient separation and detection of a large number of peaks in a short time, exemplified by the analysis of a tryptic digest of bovine serum albumin (BSA). The capability of the developed capillary surface coating was demonstrated by the separation of human plasma and cerebrospinal fluid (CSF).

Acetonitriles↗

On-column polymer-imbedded graphite inlet electrode for capillary electrophoresis coupled on-line with flow injection analysis in a poly(dimethylsiloxane) interface.

A method for coupling an electrophoretic driven separation to a liquid flow, using conventional fused-silica capillaries and a soft polymeric interface is presented. A novel design of the electrode providing high voltage to the electrophoretic separation was also developed. The electrode consisted of a conductive polyimide/graphite imbedded coating immobilized onto the capillary electrophoresis (CE) column inlet. This integrated electrode gave the same separation performance as a commonly used platinum electrode. The on-column electrode also showed good electrochemical stability in chronoamperometric experiments. In addition, with this electrode design, the electrode position relative to the inlet end of the CE column will always be constant and well defined. The on-line flow injection analysis (FIA)-CE system was used with electrospray ionization (ESI)-time of flight (TOF)-mass spectrometry detection. The preparation of the PDMS (poly(dimethylsiloxane)) interface for FIA-CE is described in detail and used for initial tests of the on-column polymer-imbedded graphite inlet electrode. In this interface, a pressure-driven liquid flow, a make up CE electrolyte and a CE column inlet meet in a two-level cross (95 microm ID) in the PDMS structure, enabling independent flow characterization.

Dimethylpolysiloxanes↗

A comparison of the electrochemical stabilities of metal, polymer and graphite coated nanospray emitters.

Chronoamperometry (CA) and cyclic voltammetry (CV) were used to compare the electrochemical behavior of metal, polymer and graphite coated nanospray emitters. It is shown that electrochemical reactions occurring at the emitter surface limit the lifetime of the noble metal coated nanospray emitters while the graphite coated nanospray emitters show good electrochemical stabilities. Although the surface of the graphite coated emitters may be passivated at positive potentials, the conductive coating is not lost as for the noble metal coated nanospray emitters. The graphite coated nanospray emitters still produced a stable nanospray signal despite the presence of a passivated surface. The polymer (i.e. polyaniline) coated nanospray emitters showed very low electrochemical activity and could not be thoroughly tested by CA. The relative short lifetimes seen in the electrochemical tests are qualitatively comparable with those obtained in nanospray experiments, in which only the outmost tip of the emitter is electrochemically active. However, the electrochemical stress during CA far exceeds the stress during ESI, which implies that CA can be used to perform quick and simple estimates of emitter stabilities. To our knowledge, this is the first time the electrochemical behavior of metal, polymer and graphite coated nanospray emitters has been compared.

Journal Article↗

Hadamard transform time-of-flight mass spectrometry: a high-speed detector for capillary-format separations.

This work demonstrates that with an intrinsic duty cycle of 50% and spectral storage speeds up to 277 spectra s(-1) Hadamard transform time-of-flight mass spectrometry (HT-TOFMS) is a promising detector for any capillary-format separation that can be coupled to MS by electrospray ionization. Complete resolution of the components of a nine-peptide standard was achieved by coupling pressurized-capillary electrophoresis (pCE) to HT-TOFMS. The addition of pressure to the separation capillary decreased analysis times and stabilized the electrospray ionization source. Pulsed-pressurized injection of reserpine was used to experimentally simulate narrower peaks than those obtained in the pCE. HT-TOFMS was able to sample peaks having widths in the millisecond range.

Electrophoresis, Capillary↗

A conductive polymeric material used for nanospray needle and low-flow sheathless electrospray ionization applications.

A conductive polypropylene/graphite mixture is used for the production of polymeric nanospray needle emitters and as a coating on fused-silica capillaries that are used for sheathless electrospray ionization (ESI). The described production of these polymeric nanospray needle emitters and sheathless ESI contacts is exceptionally easy and at a very low cost. The described polymeric nanospray emitters have shown excellent features regarding their chemical inertness and spray performance. The long-term stability of the nanospray needles exceeds 24 h of continuous use. Furthermore, the resistance to electrical discharges, which is one of the factors that often limits the lifetime of metal coated tips, has proven to be outstanding. A voltage of up to 5 kV could be applied without loss of spray performance. The use of polypropylene emitters offers a number of desirable features, as compared to silica based emitters. Among these features are mechanical flexibility and simplified regeneration of the nanospray needle. Continuous nanospray of peptides and proteins in conjunction with orthogonal time-of-flight mass spectrometry are shown with signal relative standard deviations of 5%. In addition, the polypropylene/graphite mixture has also been applied as the conductive contact for sheathless ESI in fast capillary electrophoresis separations.

Equipment Design↗

Peptide mapping of proteins in human body fluids using electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry.

Human body fluids have been rediscovered in the post-genomic era as great sources of biological markers and perhaps particularly as sources of potential protein biomarkers of disease. Analytical tools that allow rapid screening, low sample consumption, and accurate protein identification are of great importance in studies of complex biological samples and clinical diagnosis. Mass spectrometry is today one of the most important analytical tools with applications in a wide variety of fields. One of the fastest growing applications is in proteomics, or the study of protein expression in an organism. Mass spectrometry has been used to find post-translational modifications and to identify key functions of proteins in the human body. In this study, we review the use of human body fluids as sources for clinical markers and present new data that show the ability of Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) to identify and characterize proteins in four human body fluids: plasma, cerebrospinal fluid (CSF), saliva, and urine. The body fluids were tryptically digested without any prior separation, purification, or selection, and the digest was introduced into a 9.4 T FTICR mass spectrometer by direct-infusion electrospray ionization (ESI). Even though these samples represent complex biological mixtures, the described method provides information that is comparable with traditional 2D-PAGE data. The sample consumption is extremely low, a few microliters, and the analysis time is only a few minutes. It is, however, evident that the separation of proteins and/or peptides must be included in the methodology, in order to detect low-abundance proteins and other proteins of biological relevance.

Biomarkers↗

Rapid analysis of tryptically digested cerebrospinal fluid using capillary electrophoresis-electrospray ionization-Fourier transform ion cyclotron resonance-mass spectrometry.

Mass spectrometry has in recent years been established as the method of choice for protein identification and characterization in proteomics. Capillary electrophoresis (CE) is a fast and efficient method for the separation of peptides and proteins. The on-line combination of CE with Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) has been shown to be a powerful tool in the analysis of complex mixtures of proteins. This paper presents the first results from a proteomic analysis of human cerebrospinal fluid proteins by tryptic digestion and CE-FTICR-MS, where 30 proteins could be identified on a 95% confidence level with mass measurement errors less than 5 ppm.

Cerebrospinal Fluid↗