PubMed Health⌕ Search

Biomedical subjects

Malin Edvardsson

Publications and source records attributed to Malin Edvardsson.

3 recordsLinked to original sources

Investigation of binding event perturbations caused by elevated QCM-D oscillation amplitude.

We report measurements with the quartz crystal microbalance with dissipation monitoring (QCM-D) technique, with focus on how the shear oscillation amplitude of the sensor surface influences biorecognition binding events. Technically, this is made as reported recently (M. Edvardsson, M. Rodahl, B. Kasemo, F. Höök, Anal. Chem., 2005, 77(15), 4918-4926) by operating the QCM in dual frequency mode; one harmonic (n = n1) is utilized for continuous excitation of the QCM-D sensor at resonance at variable driving amplitudes (1-10 V), while the second harmonic (n not equaln(1)) is used for combined f and D measurements. By using one harmonic as a "probe" and the other one as an "actuator", elevated amplitudes can be used to perturb - or activate - binding reactions in a controlled way, while simultaneously maintaining the possibility of probing the adsorption and/or desorption events in a non-perturbative manner using combined f and D measurements. In this work we investigate the influence of oscillation amplitude variations on the binding of NeutrAvidin-modified polystyrene beads (slashed circle approximately 200 nm) to a planar biotin-modified lipid bilayer supported on an SiO2-modified QCM-D sensor. These results are further compared with data on an identical system, except that the NeutrAvidin-biotin recognition was replaced by fully complementary DNA hybridization. Supported by micrographs of the binding pattern, the results demonstrate that there exists, for both systems, a unique critical oscillation amplitude, A(c), below which binding is unaffected by the oscillation, and above which binding is efficiently prevented. Associated with A(c), there is a critical crystal radius, r(c), defining the central part of the crystal where binding is prevented. From QCM-D data, A(c) for the present system was estimated to be approximately 6.5 nm, yielding a value of r(c) of approximately 3 mm--the latter number was nicely confirmed by fluorescent- and dark-field micrographs of the crystal. Furthermore, the fact that A(c) is observed to be identical for the two types of biorecognition reactions suggests that it is neither the strength, nor the number of contact points, that determine the amplitude at which binding is prevented. Rather, particle size seems to be the determining parameter.

Journal Article↗

A dual-frequency QCM-D setup operating at elevated oscillation amplitudes.

An often raised, but rarely addressed, question with respect to applications of the quartz crystal microbalance technique is whether the shear oscillation of the sensor surface influences the adsorption kinetics or binding events being studied. Motivated by this uncertainty, as well as by the possibility of using elevated amplitudes to influence and steer specific biomolecular interactions, we have further developed the quartz crystal microbalance with dissipation monitoring (QCM-D) technique to operate in dual-frequency mode. One mode (one harmonic) is utilized for continuous excitation of the QCM-D sensor at resonance, at variable driving amplitudes, while the other mode (another harmonic) is used for combined frequency and energy dissipation (damping) measurements. To evaluate this experimental approach, we investigated the following: (i) the well-established process by which intact lipid vesicles adsorb and decompose into a planar supported lipid bilayer on SiO2, recently shown to be very sensitive to external perturbations, and (ii) specific streptavidin binding to biotin-modified surfaces. In the former case, we observed a clear influence of elevated oscillation amplitudes on the bilayer formation kinetics, while in the latter case, no influence was observed for protein monomers. However, binding was inhibited when the biotin-binding protein was coupled to colloidal particles (o.d. approximately 200 nm).

Journal Article↗