PubMed Health⌕ Search

Biomedical subjects

Manabu Sudo

Publications and source records attributed to Manabu Sudo.

3 recordsLinked to original sources

Cerebral air embolism during imaging of a sentinel lymphatic drainage in the respiratory tract.

We report a rare but notable case of cerebral air embolism complicating transthoracic intrapulmonary injection of an imaging agent used to locate sentinel lymph nodes. After a bolus injection of 2 mL of iopamidol into the peritumoral area with a 23-gauge needle, the patient complained of complete paralysis on his left side. Intraaortic gas was detected by computed tomography immediately after the injection. The patient recovered spontaneously without any additional complication. Surgeons should be aware of this rare but possible complication during sentinel lymph node assessment.

Aged↗

Video-assisted transcatheter lung perfusion regional chemotherapy.

OBJECTIVE: To establish a technique for performing isolated lung perfusion (ILP) under video-assisted thoracic surgery (VATS) to treat unresectable lung malignancies. METHODS: Under fluoroscopic and thoracoscopic guidance, five canine left lungs were isolated by means of an endovascular technique comprising pulmonary artery cannulation through the right femoral vein and pulmonary vein cannulation through the left auricular appendage (VATS-ILP). ILP was performed for 20 min at a flow rate of 30 ml/min with a high-dose cisplatin solution (50 microg/ml). Toxicity and pharmacokinetics of VATS-ILP were compared with those of conventional ILP performed in five additional lungs. RESULTS: VATS-ILP was performed safely without adverse reaction. Both VATS-ILP and conventional ILP delivered a high dose of cisplatin to the treated lung (total platinum concentration: 48+/-17 microg/g tissue for VATS-ILP vs. 51+/-19 microg/g tissue for conventional ILP, P>0.1) without significant systemic leakage (total platinum concentration: 0.4+/-0.1 microg/ml plasma vs. 0.5+/-0.2 microg/ml plasma, P>0.1). In addition, no significant differences were observed between the groups in the serum lactate dehydrogenase level, serum angiotensin-converting enzyme level, body weight change, or mid-term histological change following ILP. A significantly smaller thoracotomy was used for VATS-ILP than for conventional ILP (4.7+/-0.4 cm for VATS-ILP vs. 12+/-0.7 cm for conventional ILP, P<0.001) because VATS-ILP required neither arteriotomy nor venotomy. CONCLUSIONS: We established a canine VATS-ILP model that showed pharmacokinetic potential similar to that of conventional ILP. A clinical trial of VATS-ILP with cytotoxic drugs is warranted.

Animals↗

Quantitative computed tomography versus spirometry in predicting air leak duration after major lung resection for cancer.

BACKGROUND: Emphysema is a well-known risk factor for developing air leak or persistent air leak after pulmonary resection. Although quantitative computed tomography (CT) and spirometry are used to diagnose emphysema, it remains controversial whether these tests are predictive of the duration of postoperative air leak. METHODS: Sixty-two consecutive patients who were scheduled to undergo major lung resection for cancer were enrolled in this prospective study to define the best predictor of postoperative air leak duration. Preoperative factors analyzed included spirometric variables and area of emphysema (proportion of the low-attenuation area) that was quantified in a three-dimensional CT lung model. Chest tubes were removed the day after disappearance of the air leak, regardless of pleural drainage. Univariate and multivariate proportional hazards analyses were used to determine the influence of preoperative factors on chest tube time (air leak duration). RESULTS: By univariate analysis, site of resection (upper, lower), forced expiratory volume in 1 second, predicted postoperative forced expiratory volume in 1 second, and area of emphysema (< 1%, 1% to 10%, > 10%) were significant predictors of air leak duration. By multivariate analysis, site of resection and area of emphysema were the best independent determinants of air leak duration. The results were similar for patients with a smoking history (n = 40), but neither forced expiratory volume in 1 second nor predicted postoperative forced expiratory volume in 1 second were predictive of air leak duration. CONCLUSIONS: Quantitative CT is superior to spirometry in predicting air leak duration after major lung resection for cancer. Quantitative CT may aid in the identification of patients, particularly among those with a smoking history, requiring additional preventive procedures against air leak.

Aged↗