PubMed Health⌕ Search

Biomedical subjects

Mandeep S Sagoo

Publications and source records attributed to Mandeep S Sagoo.

5 recordsLinked to original sources

UK national survey of enucleation, evisceration and orbital implant trends.

AIM: To evaluate current clinical practice in the UK in the management of the anophthalmic socket; choice of enucleation, evisceration, type of orbital implant, wrap, motility pegging and complications. METHODS: All consultant ophthalmologists in the UK were surveyed by postal questionnaire. Questions included their practice subspecialty and number of enucleations and eviscerations performed in 2003. Specific questions addressed choice of implant, wrap, motility pegging and complications. RESULTS: 456/896 (51%) consultants responded, of which 162 (35%) had a specific interest in oculoplastics, lacrimal, orbits or oncology. Only 243/456 (53%) did enucleations or eviscerations. 92% inserted an orbital implant after primary enucleation, 69% after non-endophthalmitis evisceration, whereas only 43% did so after evisceration for endophthalmitis (50% as a delayed procedure). 55% used porous orbital implants (porous polyethylene, hydroxyapatite or alumina) as their first choice and 42% used acrylic. Most implants inserted were spherical, sized 18-20 mm in diameter. 57% wrapped the implant after enucleation, using salvaged autogenous sclera (20%), donor sclera (28%) and synthetic Vicryl or Mersilene mesh (42%). A minority (7%) placed motility pegs in selected cases, usually as a secondary procedure. 14% of respondents reported implant exposure for each type of procedure and extrusion was reported by 4% after enucleation and 3% after evisceration. CONCLUSIONS: This survey highlights contemporary anophthalmic socket practice in the UK. Most surgeons use porous orbital implants with a synthetic wrap after enucleation and only few perform motility pegging.

Consultants↗

Biometry accuracy using zero- and negative-powered intraocular lenses.

PURPOSE: To audit the accuracy of biometry using the SRK/T formula when negative- or zero-powered intraocular lenses (IOLs) are predicted and to compare the results between A-scan, B-scan, and optical methods of biometry. SETTING: Moorfields Eye Hospital, London, United Kingdom. METHODS: This retrospective analysis comprised 78 eyes of 54 patients having cataract surgery with zero- or negative-powered IOLs. Axial lengths were measured with A-scan, B-scan, applanation, or optical methods. Differences between SRK/T-predicted and actual postoperative refraction were analyzed for 75 eyes having cataract surgery. Ocular comorbidity, visual acuity, and biometry readings were also compared. RESULTS: Forty-one percent of 75 patients analyzed were within +/-1.00 diopter (D) of the predicted refraction, although there was a significant tendency toward a hyperopic overcorrection by 1.14 D (95% confidence interval, 0.89-1.39 D). This overcorrection error was consistent across all 3 biometry methods used to estimate axial length and increased with the use of stronger (more negative) IOLs. CONCLUSION: Surgeons should be aware of the tendency for negative-powered lenses to overcorrect and lead to a hyperopic outcome when using the SRK/T biometry formula in highly myopic eyes. A weaker-powered negative IOL is recommended to aim for a more myopic postoperative outcome by about 1.00 to 2.00 D.

Accommodation, Ocular↗