PubMed Health⌕ Search

Biomedical subjects

Manfred Bodenlenz

Publications and source records attributed to Manfred Bodenlenz.

5 recordsLinked to original sources

Rapid online-SPE-MS/MS method for ketoprofen determination in dermal interstitial fluid samples from rats obtained by microdialysis or open-flow microperfusion.

Pharmacokinetic studies of topical ketoprofen formulations using continuous sampling techniques such as microdialysis (MD) or open-flow microperfusion (OFM) require sensitive assays due to small sample volumes. A simple and easy online-SPE-MS/MS method for ketoprofen analysis was developed for both MD and OFM samples obtained from rat dermal tissue. The quantification range is 25-5000 ng/ml with a limit of detection of 3 ng/ml using only 10 microl sample volume. The method is characterized by a simple setup using a short polymeric SPE column (OASIS HLB) for desalting with 1.5 min run times in combination with a sensitive MS detection in negative ESI MRM mode. An easy sample workup procedure was used which enables high throughput analysis of a large number of samples for pharmacokinetic studies. In addition, a commercial available (fenoprofen) as well as an isotopically labelled (deuterated ketoprofen) standard were investigated as potential internal standards. The method was validated according to FDA guidelines for bioanalytical validation in terms of accuracy, intra-batch and inter-batch precision, linearity, matrix effect, recovery and stability for both internal standards. Accuracies were 98-113% (fenoprofen) and 95-108% (deuterated ketoprofen), intra-batch precision was 2-3% R.S.D. (fenoprofen) and 2-6% R.S.D. (deuterated ketoprofen), and inter-batch precision was 2-6% R.S.D. (fenoprofen) and 3-6% R.S.D. (deuterated ketoprofen) over the entire quantification range. The presented method was applied to dermal interstitial fluid samples obtained in a topical administration study of ketoprofen in rats.

Animals↗

Measurement of interstitial insulin in human adipose and muscle tissue under moderate hyperinsulinemia by means of direct interstitial access.

Insulin's action to stimulate glucose utilization is determined by the insulin concentration in interstitial fluid (ISF) of insulin-sensitive tissues. The concentration of interstitial insulin has been measured in human subcutaneous adipose tissue and skeletal muscle, however, never in parallel. The aim of this study was to compare interstitial insulin levels between both tissue beds by simultaneous measurements and to verify and quantify low peripheral ISF insulin fractions as found during moderate hyperinsulinemia. Nine healthy subjects (27.2 +/- 0.8 yr) were investigated. A euglycemic-hyperinsulinemic clamp was started with a primed-constant intravenous insulin infusion of 1 mU x kg(-1) x min(-1). For direct access to ISF, macroscopically perforated open-flow microperfusion catheters were inserted in both tissues. During steady-state conditions (9.5 h), interstitial effluents were collected in 30-min fractions using five different insulin concentrations in the inflowing perfusates ("no net flux" protocol). Regression analysis of insulin concentrations in perfusates and effluents yielded the relative recovery and the perfusate insulin concentration, which was in equilibrium with the surrounding tissue. Thus, in subcutaneous adipose tissue and skeletal muscle, the mean ISF-to-serum insulin level was calculated as 21.0% [95% confidence interval (CI) 17.5-24.5] and 26.0% (95% CI 19.1-32.8; P = 0.14), respectively. Recoveries for insulin averaged 51 and 64%, respectively. The data suggest that the concentrations of insulin arising in healthy subjects at the level of ISF per se are comparable between subcutaneous adipose and skeletal muscle tissue. The low interstitial insulin fractions seem to confirm reports of low peripheral insulin levels during moderate insulin clamps.

Adipose Tissue↗

A double-blind, randomized, dose-response study investigating the pharmacodynamic and pharmacokinetic properties of the long-acting insulin analog detemir.

OBJECTIVE: To investigate the pharmacodynamic profile and duration of action for five subcutaneous doses of insulin detemir (0.1, 0.2, 0.4, 0.8, and 1.6 units/kg; 1 unit = 24 nmol) and one subcutaneous dose of NPH insulin (0.3 IU/kg; 1 IU = 6 nmol). RESEARCH DESIGN AND METHODS: This single-center, randomized, double-blind, six-period, crossover study was carried out as a 24-h isoglycemic clamp (7.2 mmol/l) in 12 type 1 diabetic patients. RESULTS: Duration of action for insulin detemir was dose dependent and varied from 5.7, to 12.1, to 19.9, to 22.7, to 23.2 h for 0.1, 0.2, 0.4, 0.8, and 1.6 units/kg, respectively. Interpolation of the dose-response relationships for AUC(GIR) (area under the glucose infusion rate curve) revealed that a detemir dose of 0.29 units/kg would provide the same effect as 0.3 IU/kg NPH but has a longer duration of action (16.9 vs. 12.7 h, respectively). Lower between-subject variability was observed for insulin detemir on duration of action (0.4 units/kg insulin detemir vs. 0.3 IU/kg NPH, P < 0.05) and GIR(max) (maximal glucose infusion rate) (0.2 and 0.4 units/kg insulin detemir vs. 0.3 IU/kg NPH, both P < 0.05). Assessment of endogenous glucose production (EGP) and peripheral glucose uptake (PGU) resulted in an AOC(EGP) (area over the EGP curve) of 636 mg/kg (95% CI 279-879) vs. 584 (323-846) and an AUC(PGU) (area under the PGU curve) of 173 (47-316) vs. 328 (39-617) for 0.29 units/kg detemir vs. 0.3 IU/kg NPH, respectively. CONCLUSIONS: This study shows that insulin detemir provides a flat and protracted pharmacodynamic profile.

Adolescent↗

Interstitial glucose kinetics in subjects with type 1 diabetes under physiologic conditions.

We investigated the dynamic relationship between interstitial glucose (IG) in the subcutaneous adipose tissue and plasma glucose (PG) during physiologic conditions in type 1 diabetes mellitus (T1DM). Nine subjects with T1DM (5/4 M/F; age, 33 +/- 13 years; body mass index, 26.6 +/- 4.3 kg/m(2); glycosylated hemoglobin [HbA(1c)], 8.6% +/- 0.9%; mean +/- SD) treated by continuous subcutaneous insulin infusion (CSII) with insulin lispro were studied over 12 hours after a standard meal (40 g carbohydrate [CHO]) and prandial insulin. IG was measured by open flow microperfusion. Nine compartment models were postulated to account for temporal variations in the IG/PG ratio. The models differed in the inclusion of physiologically motivated alterations of pathways entering/leaving the IG compartment in the adipose tissue. The best model included zero order (constant) glucose disposal from the interstitial fluid (ISF) and insulin-stimulated glucose transfer from plasma to the ISF. The former effect is expressed by a positive association between the IG/PG ratio and PG, eg, a decrease in PG from 9 to 3.3 mmol/L lowers the IG/PG ratio by 0.1. The latter effect results in the IG/PG ratio to be increased by 0.03 per 10 mU/L of plasma insulin. We were not able to detect the stimulatory effect of insulin on glucose disappearance from the ISF. In conclusion, we developed and quantified a model of IG kinetics in the adipose tissue applicable to physiologic conditions in subjects with T1DM.

Adipose Tissue↗

Closing the loop: the adicol experience.

The objective of the project Advanced Insulin Infusion using a Control Loop (ADICOL) was to develop a treatment system that continuously measures and controls the glucose concentration in subjects with type 1 diabetes. The modular concept of the ADICOL's extracorporeal artificial pancreas consisted of a minimally invasive subcutaneous glucose system, a handheld PocketPC computer, and an insulin pump (D-Tron, Disetronic, Burgdorf, Switzerland) delivering subcutaneously insulin lispro. The present paper describes a subset of ADICOL activities focusing on the development of a glucose controller for semi-closed-loop control, an in silico testing environment, clinical testing, and system integration. An incremental approach was adopted to evaluate experimentally a model predictive glucose controller. A feasibility study was followed by efficacy studies of increasing complexity. The ADICOL project demonstrated feasibility of a semi-closed-loop glucose control during fasting and fed conditions with a wearable, modular extracorporeal artificial pancreas.

Blood Glucose↗