PubMed Health⌕ Search

Biomedical subjects

Manfred G Wichmann

Publications and source records attributed to Manfred G Wichmann.

4 recordsLinked to original sources

Loading of bone surrounding implants through three-unit fixed partial denture fixation: a finite-element analysis based on in vitro and in vivo strain measurements.

Implant-borne fixed partial dentures (FPDs), whether cementable or screwable superstructures, ought to display a true passive fit. The objective of this in vivo-based finite-element analysis is, therefore, to quantify the degree of stress which occurs in the bone around the implants as a result of the fixation of cemented and screw-retained FPDs. On the basis of a simulated patient situation with two implants, six groups of implant-supported superstructures containing 10 samples each were fabricated. Strain gauges which were mounted on the pontics of the restorations were subsequently used to take in vivo measurements (Ethics Commission Approval No. 2315). Taking the values obtained as a basis, the von Mises equivalent stress was chosen to illustrate bone loading in three-dimensional finite-element models. Superstructure fixation caused residual interface stress as high as 30 MPa. Similar stress magnitudes can be observed for axial implant loading of 200 N. Assuming that the axial loading of a single implant with 200 N is within the bone's physiological range, it can be concluded that the degree of stress resulting from the fixation of superstructures alone does not constitute a risk.

Cementation↗

Cement fixation and screw retention: parameters of passive fit. An in vitro study of three-unit implant-supported fixed partial dentures.

It is generally assumed that passively fitting superstructures are a prerequisite for long-lasting implant success. In the study presented, the strain development of three-unit implant fixed partial dentures (FPDs) was evaluated at the bone surrounding the implant and on the superstructure using a strain gauge technique. Six groups of three-unit FPDs representing the commonly used techniques of bridge fabrication were investigated with 10 samples each, in order to quantify the influence of impression technique, mode of fabrication and retention mechanism on superstructure fit. Two ITI implants (Straumann, Waldenburg, Switzerland) were anchored in a measurement model according to a real-life patient situation and strain gauges were fixed mesially and distally adjacent to the implants and on the bridge pontics. The developing strains were recorded during cement setting and screw fixation. For statistical analysis, multivariate two sample tests were performed setting the level of significance at P=0.1. None of the investigated bridges revealed a truly passive fit without strains occurring. About 50% of the measured strains were found to be due to impression taking and model fabrication, whereas the remaining 50% were related to laboratory inaccuracies. The two impression techniques used did not reveal any significant differences in terms of precision. Both modes of fixation--i.e. cement and screw retention--provoked equally high stress levels. In the fabrication of screw-retained FPDs, similar results were obtained from the use of burn-out plastic copings and the technique of casting wax moulds to premachined components. Bonding bridge frames onto gold cylinders directly on the implants significantly reduces strain development.

Aged↗

Mandibular two-implant telescopic overdentures.

To stabilize mandibular overdentures in edentulous patients, various connector types which can be attached to between two and four implants placed in the anterior mandible are possible. Treatment using non-rigid telescopic connectors on two interforaminal implants for overdenture stabilization began in 1989. The objective of this study is to investigate soft- and hard-tissue conditions as well as prosthesis function after a period of 10 years. This also involved an evaluation of correlations between radiographic and clinical parameters. Twenty-three subjects with 46 interforaminal implants (ITI solid screw implants, 12 mm in length, 4.1 mm in diameter; 10.4 years in situ, range, 8-12.8 years) were investigated. Modified plaque index (mPI), sulcus fluid flow rate (SFFR), modified sulcus bleeding index (mBI), probing depth (PD), distance from implant crown margin to the coronal border of the peri-implant mucosa (DIM), attachment level (AL), width of keratinized mucosa (KM), Periotest values (PTVs) and prosthesis function were evaluated. In the radiographic evaluation, the distance between implant shoulder and first crestal bone-implant contact (DIB) in mm and the horizontal bone loss (HBL) in mm were measured. The relatively high mPI scores (mean, 0.82; score, 0 in 44.4%; SD, 0.83) did not result in increased SFFR scores (mean, 12; min, 3, max, 38; SD, 7.43) or higher mBI scores (mean, 0.35; score, 0 in 70.8%; SD, 0.59), which was commensurate with healthy peri-implant mucosa. A mean PD value of 2.15 mm (min, 1 mm; max, 5 mm; SD, 0.96) and a mean DIM value of 0.28 mm (min, 0 mm; max, 2 mm; SD, 0.52) were measured. The implants were stable, showing a mean Periotest value of -1.91 (max, 02, min, -6; SD, 1.76). A mean DIB of 3.19+/-0.95 mm (range, 1.3-5.16 mm) and a mean HBL of 1.6+/-1.52 mm (range, 0.28-8.33 mm) were calculated. A correlation was found between DIB and the parameters SFFR (P=0.060), DIM (P=0.042), AL (P=0.050) and especially PTV (P<0.01), leading to the assumption that these clinical parameters may be useful indicators of peri-implant bone loss. The results of the 10-year follow-up examination show that non-rigid telescopic connectors with two interforaminal implants for overdenture stabilization appear to be an efficient and effective long-term treatment modality in severely resorbed edentulous mandibles. Particularly in geriatric patient treatment this concept may provide advantages in terms of handling, cleaning and long-term satisfaction.

Aged↗

In vivo stress behavior in cemented and screw-retained five-unit implant FPDs.

PURPOSE: When fixing implant-supported fixed partial dentures (FPDs), it is important to achieve passive fit. The objective of the in vivo study presented was to quantify the strain development during the fixation of screw- and cement-retained FPDs. MATERIALS AND METHODS: After informed patient consent had been obtained (Ethics commission Approval No. 2315; FAU Erlangen-Nuremberg, Germany), four groups of five-unit FPDs (five samples per group) were fabricated and investigated in vivo. Group 1: Cementable, repositioning technique impression, burn out plastic coping; Group 2: Screwable, pickup technique impression, burn out plastic coping; Group 3: Screwable, pickup technique impression, cast to gold cylinder; Group 4: Screwable, pickup technique impression, bonded to gold cylinder. Two strain gauges (SG) were attached to the pontics of each bridge (SG-M and SG-D) to measure the strains that occurred during either the cementing or screw-in process. The final values were recorded for analysis. RESULTS: The mean strain values (microm/m) for each SG were: Group 1: SG-M 32 microm/m, SG-D: 89 microm/m; Group 2: SG-M 302 microm/m, SG-D: 197 microm/m; Group 3: SG-M 458 microm/m, SG-D: 268 microm/m; Group 4: SG-M 269 microm/m, SG-D: 52 microm/m. CONCLUSIONS: Although the bridges were clinically acceptable, none of them revealed a truly passive fit with zero microstrain. In contrast to conventional screw-retained bridges, cement retention seems to result in lower strain levels. Bonding bridge pontics to prefabricated implant components seems to allow both the retrievability of a screw-retained bridge and produce moderate strain values.

Aged↗