Outcome analysis and rational management of enhancing lesions incidentally detected on contrast-enhanced MRI of the breast.

OBJECTIVE: The purpose of our study was to assess the prevalence, characteristics, and clinical consequence of incidentally detected enhancing lesions on MRI of the breast. SUBJECTS AND METHODS. MRI of the breast (1.0-T scanner, dynamic gadolinium-enhanced T1-weighted three-dimensional gradient-echo sequence, double breast coil) was performed on 1273 women for different indications. Enhancing incidental lesions were defined as enhancing lesions on MRIs that were not expected from findings on the previous conventional imaging. They were classified in five assessment categories using a scoring system based on morphologic and kinetic enhancement characteristics. Detection of enhancing incidental lesions resulted in a review of mammograms and sonograms with the aim of also localizing these lesions on conventional imaging. The lesions were either biopsied or followed up. RESULTS: Twenty-five percent (274/1086) of all enhancing lesions detected in the study population were enhancing incidental lesions. Enhancing incidental lesions were found in 16% (210/1273) of all study patients. Forty-one percent (113/274) of the enhancing incidental lesions were histologically confirmed. Forty-eight percent (54/113) of the biopsied and 20% (54/274) of all enhancing incidental lesions were malignant. Eleven percent (54/508) of all malignant lesions occurring in the 1273 women were detected solely through additional MRI. Fifty-seven percent (31/54) of these MRI-detected malignant lesions could be identified on a reevaluation of sonograms and mammograms. CONCLUSION: Detection of enhancing incidental lesions should lead to a thorough reevaluation of mammograms and sonograms. If not reidentified, suspicious enhancing incidental lesions should be biopsied, and enhancing incidental lesions that are probably benign should be carefully followed up. Indeterminate enhancing incidental lesions should be histologically examined by minimally invasive techniques or, if they are small, followed up by another MRI 6 months later.

Adolescent↗

Distribution of ventilation in lung transplant recipients: evaluation by dynamic 3He-MRI with lung motion correction.

RATIONALE AND OBJECTIVES: The ability of motion corrected dynamic 3He-magnetic resonance imaging (MRI) to discriminate distributional patterns of inhaled hyperpolarized 3He between different groups of lung transplant recipients was evaluated. METHODS: An ultrafast low-angle shot 2D sequence (temporal resolution 128 ms) was used for ventilation 3He-MRI of 11 single and 6 double lung transplant recipients. After digital motion correction, signal kinetics were evaluated in a tracheal and 7 pulmonary regions of interest. Results from grafts and native lungs as well as from normal and rejected grafts were compared with each other and to reference values from healthy subjects. RESULTS: In emphysema patients, median alveolar rise time, a parameter for increase of alveolar signal, was 0.28 seconds for the graft and 0.48 seconds for the native lung, in fibrosis patients its median was 0.46 seconds for the graft and 0.21 seconds for the native lung. In double lung recipients, alveolar rise time was 0.29 seconds in normal and clinically rejected grafts. CONCLUSIONS: Dynamic ventilation 3He-MRI discriminated normal lung grafts from diseased native lungs in single lung recipients. Graft rejection in double lung recipients could not be discriminated.

Female↗

CT attenuation of paired HRCT scans obtained at full inspiratory/expiratory position: comparison with pulmonary function tests.

The purpose of this prospective study was to measure lung attenuation at paired HRCT obtained at full inspiratory/expiratory position, to correlate with pulmonary function tests (PFTs) and to characterize different types of ventilatory impairment. One hundred fifty-five patients with and without pulmonary disease underwent paired HRCT obtained at full inspiratory/expiratory position. Three scan pairs were evaluated by densito- and planimetry using dedicated software. The PFTs were available for correlation in all patients (mean interval 5 days). Mean lung density (MLD) at full inspiration was -813 HU, and MLD at full expiration was -736 HU; both, as well as the expiratory attenuation increase, demonstrated significant correlations with static and dynamic lung volumes: up to r=0.68, p<0.05 for residual volume. The MLD and emphysema indices correlated markedly better for scans obtained at full expiration than at full inspiration, e.g. correlation with the residual volume: r=0.68 compared with r=0.55. Even better correlations were obtained for the lung area (229 cm(2) at inspiration, 190 cm(2) at expiration), up to r=0.74 for the lung area in expiration and the intrathoracic gas volume. Inspiratory MLD and the expiratory attenuation increase were able to differentiate obstructive and restrictive ventilatory impairment from normal subjects, the best results were obtained from scans obtained at full expiratory position ( p<0.05). In conclusion, scans obtained at full expiratory position reveal more functional information than scans obtained at full inspiratory position. Quantitative analysis of CT obtained at full expiratory position provides good estimations of static and dynamic lung volumes as well as significant differences between normal subjects and patients with ventilatory impairment.

Female↗

Endovascular aneurysm repair: Magnetic resonance monitoring of histological organization processes in the excluded aneurysm.

BACKGROUND: The purpose of the present study was to systematically analyze the histopathologic organization processes in excluded aneurysms after endovascular stenting and to develop a noninvasive monitoring method for these processes using MRI. METHODS AND RESULTS: In 36 mongrel dogs, autologous aortic aneurysms were created. Endovascular treatment was performed using covered stents. Follow-up was after 1 week, 6 weeks, and 6 months. MRI was performed with T2-weighted turbo-spin-echo sequences and T1-weighted spin-echo sequences and was repeated after contrast bolus with gadolinium. Histopathologic findings were correlated to signal intensities (SIs) of MRI images. SIs of distinct areas were analyzed and related to the SI of the reference tissue (SI ratio). The histological organization process was gradated in the following 4 classes: class 0, detritus without organization; classes I and II, connective tissue proliferation with increasing fiber synthesis; and class III, dense fibrous connective tissue. The SI ratios of T2-weighted images were significantly reduced from 4.76 in detritus (0) to 1.70 in dense fibrous connective tissue (III) as a function of histopathologic classes. SI ratios of T1-weighted images were reduced from 1.84 (0) to 1.12 (III). Contrast bolus with gadolinium-DTPA showed no change of SI ratio in detritus (0.99) but an increase from 1.12 (I) to 1.70 (III) as organization increased. CONCLUSIONS: The histological organization of excluded aneurysms can be monitored by MRI. Progressive organization is indicated by decreasing SIs in T2- and an increasing signal increase in T1-weighted images after gadolinium bolus.

Animals↗

[Possibilities and prospects of noninvasive bypass diagnosis. Comparison of different nuclear magnetic resonance tomography methods with conventional coronary angiography].

OBJECTIVE: The aim of the study was to evaluate the patency of coronary artery bypass grafts (CABGs) with different MR imaging techniques. PATIENTS: 25 patients with 63 bypass grafts and a total of 78 distal anastomoses were studied at a 1.5-Tesla scanner. A 2-D T2-weighted breath-hold turbo spin echo sequence (Haste), a 3-D breath-hold contrast-enhanced MR angiography sequence (Fisp-3-D), and 3-D angiography sequence in navigator techniques were used. RESULTS: With the Haste and Fisp-3-D sequences, 44 of the 47 patent and 14 of the 16 occluded grafts were recognized, the sensitivity and specificity were 94% and 88%, respectively. With the Haste sequence, 80% (43/54) of the distal anastomoses were seen in good image quality, and with the Fish-3-D sequence 70% (38/54). The navigator sequence showed less sensitivity and specificity (74% and 63%, respectively). CONCLUSION: The patency of CABGs can be evaluated noninvasively with the Haste and the Fisp-3-D angiography sequences. Better results can be expected with the development of a blood-pool contrast medium and an improvement of the spatial resolution.

Aged↗

[Endovascular aneurysm therapy--long-term treatment outcomes after 7 years].

BACKGROUND: Stentgrafts for endovascular treatment of abdominal aortic aneurysms (AAA) have been commercially available since 1994, with now large numbers of implantations all over the world. PATIENTS AND METHODS: From 1994-2001, 115 patients were treated with Stentor, Vanguard and Talent stentgrafts in our institution. RESULTS: Late complications of the first- and second-generation stentgrafts as radiologic or surgical interventions to maintain complete exclusion of the aneurysm amounted to 30% with an additional 22% for observed endoleaks and configuration changes of the stentgraft. Third-generation stentgrafts had a lower complication rate of 12.2% for interventions and 18.3% for late endoleaks and graft changes. CONCLUSION: High costs of the devices, a pretty high late complication rate, and the uncertain maintenance of stentgraft function to prevent aneurysm rupture currently limit the widespread application of this new technology, leaving conventional aneurysmectomy the standard for aneurysm treatment and reserving the endovascular method for selected patients.

Aged↗

Dynamic contrast-enhanced myocardial perfusion imaging using saturation-prepared TrueFISP.

PURPOSE: To develop and test a saturation-recovery TrueFISP (SR-TrueFISP) pulse sequence for first-pass myocardial perfusion imaging. MATERIALS AND METHODS: First-pass magnetic resonance imaging (MRI) of Gd-DTPA (2 mL) kinetics in the heart was performed using an SR-TrueFISP pulse sequence (TR/TE/alpha = 2.6 msec/1.4 msec/55 degrees ) with saturation preparation TD = 30 msec before the TrueFISP readout. Measurements were also performed with a conventional saturation-recovery TurboFLASH (SRTF) pulse sequence for comparison. RESULTS: SR-TrueFISP images were of excellent quality and demonstrated contrast agent wash-in more clearly than SRTF images. The signal increase in myocardium was higher in SR-TrueFISP than in SRTF data. Precontrast SNR and peak CNR were not significantly different between both sequences despite 57% improved spatial resolution for SR-TrueFISP. CONCLUSION: SR-TrueFISP first-pass MRI of myocardial perfusion leads to a substantial improvement of image quality and spatial resolution. It is well suited for first-pass myocardial perfusion studies at cardiovascular MR systems with improved gradient hardware.

Adult↗

19F-MRI of perflubron for measurement of oxygen partial pressure in porcine lungs during partial liquid ventilation.

A method for in vivo measurement of oxygen partial pressure (pO2) in porcine lungs during partial liquid ventilation (PLV) with perflubron (PFOB) was developed. A pulse sequence for high-resolution MRI of the distribution of PFOB in the lung after intratracheal administration was developed as well. Moreover, quantitative measurements of longitudinal relaxation time T(1) of (19)F resonances for assessment of regional pO2 are described. Due to the need to acquire data during a single expiratory breathhold, only low SNRs were achieved in vivo. Therefore, simulations were performed to investigate the influence of background noise on T(1) values calculated from data with low SNR. Based on these simulations, a postprocessing strategy was developed to correct for systematic errors by background noise prior to quantitative analysis. Results of a pilot study in pigs under conditions of PLV are presented.

Animals↗

Quantification of myocardial blood flow and blood flow reserve in the presence of arterial dispersion: a simulation study.

Myocardial blood flow (MBF) can be quantified using dynamic T1-weighted MRI of diffusible tracers and a mathematical model of underlying vasculature. Quantification of MBF by means of T1- weighted MRI requires knowledge of the arterial input function (AIF). The AIF can be estimated from the left ventricular (LV) cavity. However, dispersion may occur between the LV and the tissue of interest because of the laminar blood flow profiles, branching of venules, and because of stenosis. To evaluate the influence of dispersion on the results of MBF quantification, a simulation study was performed. The dispersion was described as a convolution of the AIF with an exponential residue function. Synthetic tissue and AIF curves were analyzed and the derived parameters fit to the simulated parameters. The results show that an unaccounted dispersion may result in a systematic underestimation of MBF up to approximately 50%. Underestimation increases with increasing dispersion and with increasing MBF. Assuming equal dispersion at rest and during hyperemia, myocardial perfusion reserve (MPR) estimates are also susceptible to underestimation of approximately 20%. An unaccounted dispersion therefore can lead to systematic underestimation of both blood flow and perfusion reserve.

Computer Simulation↗

Dynamic computed tomography: a novel technique to study lung aeration and atelectasis formation during experimental CPR.

OBJECTIVE: To develop an image based technique to study the effect of different ventilatory strategies on lung ventilation and alveolar recruitment during cardiopulmonary resuscitation (CPR). DESIGN: (1) Technical development of the following components: (a) construction of an external chest compression device, which does not interfere with CT imaging, and (b) development of a software tool to detect lung parenchyma automatically and to calculate radiological density parameters. (2) Feasibility studies: three strategies of CPR ventilation were performed and imaged in one animal each (pigs, 25 kg): volume-constant ventilation (VCV), no ventilation, or continuous airway pressure (CPAP). One minute after induction of circulatory arrest inside the CT scanner, external chest compressions started at a rate of 100 cpm, and one of the ventilation modes was initiated. After 1 min, intravenous epinephrine was added as a bolus (40 microg/kg), followed by a continuous infusion (13 microg/kg per min). Six minutes later, dynamic CT acquisitions (temporal resolution: 100 ms) commenced. Simultaneously, arterial blood gases, acid base status and haemodynamics were sampled. RESULTS: Using a modified chest compression device, dynamic CT acquisitions are feasible during closed-chest CPR. In three pilot experiments with different ventilation strategies, the dedicated software tool allowed to quantify ventilated, atelectatic and over-distended fractions of total lung area. VCV showed a large amount of atelectasis, which was recruited during every respiratory cycle. No ventilation led to atelectasis to govern over 50% of the total lung area. CPAP caused less atelectasis as VCV, and no cyclic recruitment and de-recruitment phenomena were observed. CONCLUSIONS: We demonstrate a novel experimental set up, which allows quantification of different lung compartments during ongoing CPR and may become useful in comparing the direct pulmonary effects of different ventilatory strategies in the settings of Basic and Advanced Cardiac Life Support.

Animals↗

Quantification of shunt volumes in congenital heart diseases using a breath-hold MR phase contrast technique--comparison with oximetry.

AIMS: Comparison of breath-hold MR phase contrast technique in the estimation of cardiac shunt volumes with the invasive oximetric technique. METHODS AND RESULTS: Seventeen patients with various cardiac shunts (10 ASD, 3 VSD, 1 PDA, 3 PFO) and five healthy volunteers were investigated using a 1.5 Tesla system. The mean flow velocity, the mean volume flow and the transverse area in the ascending aorta and the left and right pulmonary artery were measured using the MR phase contrast breath-hold technique (through plane, FLASH 2D-sequence, TR/TE 11/5 ms, phase length 106 ms, VENC 250 cm/s). The ratio of mean flow in the pulmonary (Qp: sum of mean flows in the left and right pulmonary arteries) and the systemic circulation (Qs: mean flow in the ascending aorta) was calculated and compared with invasively measured Qp:Qs ratios. Oximetry was performed within 24 h of the MR investigation. The non-invasive shunt measurement in the 17 patients showed a mean Qp:Qs ratio of 2.00 +/- 0.86. Comparing the MR data with the invasively measured Qp:Qs showed a correlation coefficient of r = 0.91 (p < 0.001). CONCLUSION: Cardiac shunt volumes can be measured reliably using a shorter acquisition time with breath-hold MR phase contrast technique.

Adult↗

Dynamic ventilation (3)He-magnetic resonance imaging with lung motion correction: gas flow distribution analysis.

RATIONALE AND OBJECTIVES: Software was developed to correct for lung motion to improve the description of hyperpolarized (3)He gas distribution in the lung. METHODS: Five volunteers were studied by dynamic ventilation (3)He-MRI using an ultrafast FLASH 2D sequence with a temporal resolution of 128 milliseconds. Signal kinetics were evaluated in the trachea and seven parenchymal Regions of Interest. Reference ranges for healthy subjects were defined for motion-corrected and uncorrected images. RESULTS: Motion correction was successfully performed. Reference ranges were 0.11-1.21 seconds for tracheal transit time, 0-0.02 seconds for trachea-alveolar interval, 0.22-0.62 seconds for alveolar rise time and 0-76.6 arbitrary units for alveolar amplitude for motion corrected images, and 0-1.09 seconds, 0-0.11 seconds, 0.26-0.85 seconds, 46.4-99.8 arbitrary units for uncorrected images. CONCLUSIONS: Evaluation of (3)He-distribution in the lung using motion correction of dynamic (3)He-ventilation imaging is feasible and gives more narrow reference ranges.

Adult↗

Undetected malignancies of the breast: dynamic contrast-enhanced MR imaging at 1.0 T.

PURPOSE: To assess the prevalence and characteristics of malignant breast lesions not identified with magnetic resonance (MR) imaging. MATERIALS AND METHODS: Breast tissue specimens were obtained in 464 of 967 patients who had undergone dynamic gadolinium-enhanced T1-weighted fast low-angle shot three-dimensional MR imaging of both breasts. A comparison of sensitivity, specificity, and predictive values of the prospectively recorded findings of mammography, ultrasonography (US), and MR imaging with the histopathologic results was performed with receiver operating characteristic (ROC) curve analysis. MR imaging examination findings that caused a false-negative diagnosis were reviewed to identify possible sources of error. RESULTS: Histopathologic analysis revealed 244 benign and 354 malignant lesions. The sensitivity values for mammography, mammography combined with US, MR imaging alone, and the combination of all three modalities were 73.7%, 88.1%, 88.4%, and 95.5%, and the areas under the ROC curves were 0.744, 0.829, 0.850, and 0.876, respectively. Twenty-eight (8.4%) of 334 invasive and 13 (65%) of 20 intraductal carcinomas were missed with MR imaging. In eight cases, motion artifacts (n = 1), tumor location near or beyond the outer boundary of the field of view (n = 3), inadequate infusion of the contrast material (n = 1), and masking of the tumors by intensively enhanced surrounding glandular tissue (n = 3) were identified as adequate explanations for the false-negative results. The remaining missed breast cancers (n = 33) exhibited very diffuse growth patterns or were 5 mm or smaller. CONCLUSION: MR imaging did not depict 41 of 354 malignant tumors for several reasons.

Artifacts↗

Bronchopulmonary shunts in patients with chronic thromboembolic pulmonary hypertension: evaluation with helical CT and MR imaging.

OBJECTIVE: The purpose of our study was to compare differences in flow between the pulmonary and systemic circulations by assessing MR phase-contrast flow measurements and CT measurements of dilated bronchial arteries in patients with chronic thromboembolic pulmonary hypertension. MATERIALS AND METHODS: Seventeen patients were included in this study. MR phase-contrast flow measurements were used to calculate the net forward volumes in the right and left pulmonary arteries and in the ascending aorta. Single-detector helical CT scans were assessed for the presence of dilated bronchial arteries that could be delineated from the descending aorta to the mainstem bronchi. Their perpendicular cross-sectional area at the level of the main bronchi was measured using a double-threshold region of interest (> or =100-3072 H). RESULTS: The mean net forward volume in the aorta was 44.6 mL per heartbeat (R-R interval) and in the pulmonary arteries, 30 mL per R-R interval. Thus, the mean difference was 14.6 mL per R-R interval; this value represents the shunt volume between the systemic arterial and pulmonary venous circulations. On CT, dilated bronchial arteries were depicted in all patients (mean, three arteries per patient). The mean cross-sectional area of the bronchial arteries was 0.19 cm(2). Pearson's correlation coefficient (r) between cross-sectional area and shunt volume was 0.86 (p < 0.01). CONCLUSION: MR imaging was able to reveal substantial differences in flow between the systemic arterial and pulmonary venous circulations in patients with chronic thromboembolic pulmonary hypertension. These differences correlated well with the diameters of the bronchial arteries seen on helical CT. Furthermore, these differences resolved after pulmonary thromboendarterectomy. MR imaging enables the accurate estimation of flow in the bronchial arteries in patients with chronic thromboembolic pulmonary hypertension.

Adult↗

Preoperative assessment of breast cancer: sonography versus MR imaging.

OBJECTIVE: The purposes of our study were to compare the diagnostic value of whole-breast sonography and MR imaging as adjunctive techniques to mammography and to determine whether MR imaging should be used routinely in the preoperative assessment of patients with suspected breast cancer. SUBJECTS AND METHODS: . One hundred four women (age range, 34-84 years; mean age, 60 years) with findings highly suggestive of malignancy in the breast were examined with mammography, sonography, and dynamic MR imaging before undergoing surgery. All visualized suspicious lesions were correlated histologically. The diagnostic relevance of sonographic and MR imaging findings was compared with the diagnostic value of the findings of clinical examination and mammography alone. RESULTS: . Twenty-seven tumors showed multifocal or multicentric invasive growth at pathology. Of these 27, 48% were correctly diagnosed via mammography alone; 63%, via the combination of mammography and sonography; and 81%, via MR imaging. Nine of the index tumors were invisible on mammography but were detected on sonography. Use of sonography benefited 13 patients and produced two studies with false-positive findings. Use of MR imaging benefited seven patients and produced eight studies with false-positive findings. In summary, 93% of all patients gained no advantage from MR imaging. Relevant additional findings were significantly more frequent in patients with dense breasts. CONCLUSION: Although MR imaging is most sensitive for the detection of small tumors, routine preoperative MR imaging appears to be unnecessary for most patients if a combination of mammography and whole-breast sonography is used. Additional MR imaging can be restricted to problematic cases in women with dense breast parenchyma.

Adult↗

Systemic pulsatile pressure in type II endoleaks after stent grafting of experimental abdominal aortic aneurysms.

PURPOSE: To investigate pressure and maximum rate of rise of systolic pressure (peak dP/dt) in completely excluded aneurysms and endoleaks to determine the hemodynamic impact of endoleaks. METHODS: In mongrel dogs (n = 36) experimental aneurysms were created by insertion of a patch (portion of rectus abdominis muscle sheath) into the infrarenal aorta. In group I (n = 18), all aortic branches of the aneurysm were ligated and all aneurysms were completely excluded by stent grafts. Group II (n = 18) consisted of aneurysms with patent aortic side branches that represented sources of endoleaks. One week (n = 12), six weeks (n = 12), and six months (n = 12) after stent grafting, hemodynamic measurements were obtained in thrombosed aneurysms and proved endoleaks. Systemic blood pressure and intraaneurysmal pressure were simultaneously measured and the respective peak dP/dt were computed. RESULTS: At the six-month follow-up, the systolic-pressure ratio (intraaneurysmatic pressure: systemic pressure) was significantly increased in endoleaks compared to non-perfused areas (0.879 +/- 0.042 versus 0.438 +/- 0.176, p < 0.01, group II) or completely excluded aneurysms (0.385 +/- 0.221, group I). Peak dP/dt ratio (intraaneurysmal peak dP/dt: systemic peak dP/dt) was 0.922 +/- 0.154 in endoleaks, compared to 0.084 +/- 0.080 in non-perfused areas (group II, p < 0.01), and was 0.146 +/- 0.121 in completely excluded aneurysms (group I). The diastolic-pressure ratio was also increased in endoleaks compared to non-perfused areas (0.929 +/- 0.088 versus 0.655 +/- 0.231, p < 0.01, group II) or completely excluded aneurysms (0.641 +/- 0.278, group I). In excluded aneurysms, pressure exposure declined as the length of the follow-up period increased. CONCLUSION: Type II endoleaks transmit pulsatile pressure of near systemic level and indicate insufficient treatment result. In contrast, complete endovascular exclusion of aneurysms results in significantly reduced pressure exposure.

Animals↗