PubMed Health⌕ Search

Biomedical subjects

Manoj Purohit

Publications and source records attributed to Manoj Purohit.

10 recordsLinked to original sources

Truncus arteriosus communis: early and midterm results of early primary repair.

BACKGROUND: Repair of truncus arteriosus communis (TAC) in the neonatal and early infant period has become standard practice in many centers. We report our experience on early primary repair of TAC, with a focus on early and midterm results. METHODS: From July 1993 to December 2005, 29 patients with median age 28 days (range, 11 to 127), and median body weight 3.1 kg (range, 2.6 to 5.9 kg), underwent primary repair of TAC. The anatomical type of TAC was as follows: A1-2, 27; A3, 0; and A4, 2. Right ventricular outflow tract was reconstructed with an aortic (n = 7) or pulmonary homograft (n = 8), or a bovine (n = 11) or porcine valved xenograft (n = 3). Follow-up was complete for all patients. RESULTS: Hospital mortality was 3.4% (1 death due to respiratory infection). At a mean follow-up of 74 months (range, 2 to 149), 1 patient died suddenly 2 months after surgery (6-year actuarial survival 93%). Of the 27 midterm survivors, 14 (52%) underwent 30 interventional procedures including percutaneous balloon dilation with or without stenting for right ventricular outflow tract or branch pulmonary artery obstruction. Eight of them were reoperated on for right ventricle-to-pulmonary artery conduit replacement (n = 8, 23%), and aortic valve regurgitation (n = 1, 3.4%). The overall freedom from any reintervention at 6 years was 50%. Aortic valve regurgitation was trace in 15 patients, mild in 8, moderate in 4. All midterm survivors but 1 (26 of 27) had good ventricular function. CONCLUSIONS: Truncus arteriosus communis repair can be performed early with very low perioperative mortality and satisfactory midterm morbidity; the latter is mainly attributed to right ventricular outflow tract reconstruction. Interventional cardiac catheterization delays inevitable conduit replacement.

Cardiac Surgical Procedures↗

Intra-aortic balloon pumping in children undergoing cardiac surgery: an update of the Liverpool experience.

OBJECTIVE: Intra-aortic balloon pumping in children remains a rarity. We report our experience in supporting pediatric cardiac surgical patients with intra-aortic balloon pumping. METHODS: We reviewed the cases of 24 children supported with intra-aortic balloon pumping after cardiac surgery in our institution from 1994 through 2003. RESULTS: Mean age at the time of the operation was 5.0 +/- 5.6 years (range, 7 days-17.5 years). Ten patients were infants less than 6 months old. Mean weight was 18.9 +/- 18.1 kg (range, 3.5-58.7 kg). Indications for intra-aortic balloon pump deployment were postoperative hemodynamic deterioration (n = 11, 8 survivors), failure to wean off cardiopu(n = 7, 5 survivors), and prophylaxis before weaning off cardiopulmonary bypass (n = 6, 5 survivors). The balloon was inserted through the ascending aorta in infants and through the femoral artery in children. Eighteen children (7 infants) were weaned off the intra-aortic balloon pump successfully (intra-aortic balloon pump survival, 75%). Mean duration of intra-aortic balloon pump support was 121.3 +/- 140.60 hours (range, 8-670 hours). There were 3 post-intra-aortic balloon pump in-hospital deaths (survival to hospital discharge, 62.5%). Severe intra-aortic balloon pump-related complications were mesenteric ischemia in 1 patient and lower limb ischemia requiring intra-aortic balloon pump removal in 1 patient. At a mean follow-up of 85 +/- 31 months (range, 18-124 months), all 15 long-term survivors were alive and well. CONCLUSIONS: Use of an intra-aortic balloon pump is an effective modality of cardiac support in properly selected pediatric cardiac surgical patients with refractory low cardiac output. It can be safely used in small infants and neonates. In selected cases with known left ventricular dysfunction, there is a place for prophylactic use of an intra-aortic balloon pump.

Adolescent↗

Contegra bovine jugular vein right ventricle to pulmonary artery conduit in Ross procedure.

BACKGROUND: In the Ross procedure a valved conduit, most commonly pulmonary or aortic homograft, is used in place of autotransplanted pulmonary valve. Increasing demand and diminishing supply of homografts has resulted in a search for alternatives. A biological conduit from the valved segment of bovine jugular vein (Contegra) has been used successfully as an alternative. METHODS: Early clinical and echocardiographic results were analyzed retrospectively for 20 patients (median age 14.4 years) who underwent a Ross procedure with Contegra as right ventricle to pulmonary artery conduit between November and June 2003 (during the last 31 months). RESULTS: There was no operative mortality and late mortality or morbidity during the mean follow-up of 13.8 +/- 9.1 months (range 1 to 31 months). No patient required reoperation. The median gradient at discharge was 16 +/- 4.5 mm Hg, which remained unchanged at last follow-up. No deterioration in conduit or conduit valve function was noted. CONCLUSIONS: This new bovine jugular vein conduit can be a viable alternative to a homograft in the Ross procedure. The early clinical and hemodynamic results are encouraging. Ease of availability and favorable handling and technical characteristics make it more attractive than a homograft. Xenograft origin of this conduit necessitates close follow-up for assessment of durability and longer-term results.

Adolescent↗

Total extracardiac cavopulmonary connection: an alternative technique of fenestration.

Fenestrating an extracardiac conduit used for total cavopulmonary connection normally requires an additional incision on the right-sided atrium and is time consuming. Herein we describe an alternative technique that may be used to facilitate this process, which consists of creating the fenestration by using part of the atrial incision resulting from the disconnection of the inferior vena cava from the right atrium. The advantages of this technique are avoidance of an extra incision and suture line on the atrium, and the ease of construction. This may be especially useful in patients with heterotaxy syndromes with mesocardia or dextrocardia, in whom the atrial mass is displaced posteriorly and can be difficult to reach. Closure of the fenestration can be easily performed at a later stage in the cardiac catheterization laboratory by using a septal occluding device.

Anastomosis, Surgical↗

Sutureless fixation of temporary pacing wire.

A simple sutureless technique of fixing ordinary straight insulated temporary pacing wire is described by creating a floret of the insulation of the wire. It can be easily accomplished and reproduced.

Cardiac Surgical Procedures↗