PubMed Health⌕ Search

Biomedical subjects

Manojkumar Saranathan

Publications and source records attributed to Manojkumar Saranathan.

8 recordsLinked to original sources

Short breath-hold, volumetric coronary MR angiography employing steady-state free precession in conjunction with parallel imaging.

An ECG-gated, 3D steady-state free precession (SSFP) technique in conjunction with sensitivity encoding (SENSE)-based parallel imaging was implemented for short breath-hold, volumetric coronary MR angiograpy (CMRA). Two parallel imaging acquisition strategies (employing 1 R-R and 2 R-R intervals, respectively) were developed to achieve 1) very short breath-hold times (12 s for a heart rate of 60 bpm), and 2) small acquisition windows to minimize sensitivity to physiologic motion. Both strategies were examined in CMRA applications over a range of heart rates. A four-point scale blinded reading (with 4 indicating the most desirable features) revealed substantial image quality improvements for the accelerated data as compared to the nonaccelerated approach. The 1 R-R interval scheme yielded an image score of 3.39 +/- 0.60, and was found to be particularly suitable for low heart rates (P = 0.0008). The 2 R-R interval strategy yielded an image score of 3.35 +/- 0.64, and was more appropriate for higher heart rates (P = 0.03). The results demonstrate that 3D SSFP combined with parallel imaging is a versatile method for short breath-hold CMRA while maintaining high spatial resolution. This strategy permits imaging of the major coronary artery distributions in two to three breath-holds using targeted slabs, and offers the potential for single breath-hold, large-volume CMRA.

Adult↗

Feasibility of integrating high-spatial-resolution 3D breath-hold coronary MR angiography with myocardial perfusion and viability examinations.

The study was institutional review board approved and Health Insurance Portability and Accountability Act compliant. All subjects provided informed consent. Three-dimensional breath-hold coronary magnetic resonance (MR) angiography with use of steady-state free precession was performed in 12 patients up to 20 minutes after 0.2 mmol gadolinium-based contrast material per kilogram of body weight was administered. Within 24 heartbeats, a spatial resolution of up to 1.0 x 1.2 x 2.0 mm was achieved. Sixty-five (82%) of the 79 visualized coronary artery segments had a grade of 3 or 4 on a four-point scale of depiction in which grade 4 indicated excellent depiction. Twenty-seven percent (n = 21) of the 79 segments were assigned a grade of 4; 56% (n = 44), a grade of 3; 16% (n = 13), a grade of 2; and 1% (n = 1), a grade of 1. Coronary MR angiography performed as part of a first-pass myocardial perfusion and viability assessment MR imaging examination is feasible and does not involve additional imaging time.

Adult↗

Fast, three-dimensional free-breathing MR imaging of myocardial infarction: a feasibility study.

Imaging delayed hyperenhancement of myocardial infarction is most commonly performed using an inversion recovery (IR) prepared 2D breathhold segmented k-space gradient echo (FGRE) sequence. Since only one slice is acquired per breathhold in this technique, 12-16 successive breathholds are required for complete anatomical coverage of the heart. This prolongs the overall scan time and may be exhausting for patients. A navigator-echo gated, free-breathing, 3D FGRE sequence is proposed that can be used to acquire a single slab covering the entire heart with high spatial resolution. The use of a new variable sampling in time (VAST) acquisition scheme enables the entire 3D volume to be acquired in 1.5-2 min, minimizing artifacts from bulk motion and diaphragmatic drift and contrast variations due to contrast media washout.

Feasibility Studies↗

Large field-of-view real-time MRI with a 32-channel system.

The emergence of parallel MRI techniques and new applications for real-time interactive MRI underscores the need to evaluate performance gained by increasing the capability of MRI phased-array systems beyond the standard four to eight high-bandwidth channels. Therefore, to explore the advantages of highly parallel MRI a 32-channel 1.5 T MRI system and 32-element torso phased arrays were designed and constructed for real-time interactive MRI. The system was assembled from multiple synchronized scanner-receiver subsystems. Software was developed to coordinate across subsystems the real-time acquisition, reconstruction, and display of 32-channel images. Real-time, large field-of-view (FOV) body-survey imaging was performed using interleaved echo-planar and single-shot fast-spin-echo pulse sequences. A new method is demonstrated for augmenting parallel image acquisition by independently offsetting the frequency of different array elements (FASSET) to variably shift their FOV. When combined with conventional parallel imaging techniques, image acceleration factors of up to 4 were investigated. The use of a large number of coils allowed the FOV to be doubled in two dimensions during rapid imaging, with no degradation of imaging time or spatial resolution. The system provides a platform for evaluating the applications of many-channel real-time MRI, and for understanding the factors that optimize the choice of array size.

Abdomen↗

An accurate, robust, and computationally efficient navigator algorithm for measuring diaphragm positions.

PURPOSE: The purpose of this study is to develop an improved algorithm for measuring the position of the diaphragm using navigator echoes. METHODS: This algorithm was applied to navigator echo data acquired from 14 cardiac patients. For each patient, 160 navigator echo profiles were acquired across the right hemi-diaphragm along the superior-inferior direction. RESULTS: The accuracy of the proposed edge-detection algorithm was evaluated together with that of the least-squares and linear phase-shift algorithms. The estimated measurement error of the proposed algorithm was approximately two times smaller than that of the least-squares algorithm (Magn Reson Med, 1996:36: 117-123), and was approximately four times smaller than that of the linear phase-shift algorithm (Magn Reson Med, 1999;42:548-553). The computational efficiency of this algorithm was 7.5 times higher than that of the least-squares algorithm and was comparable with that of the linear phase-shift algorithm. CONCLUSION: The presented algorithm is accurate, robust, and computationally efficient in the measurement of the diaphragm position.

Adult↗

Coronary MR angiography: respiratory motion correction with BACSPIN.

PURPOSE: To improve the signal-to-noise ratio (SNR) of breath-held coronary magnetic resonance angiography (CMRA) without increasing the number or duration of breath holds. MATERIALS AND METHODS: In this BACSPIN (Breathing AutoCorrection with SPiral INterleaves) technique, a single breath-held electrocardiogram (ECG)-gated multi-slice interleaved-spiral data set is acquired, followed by repeated imaging of the same slices during free breathing. Each spiral interleaf from the breath-held data set is used as a standard for comparison with corresponding acquisitions at the same interleaf angle during free breathing. The most closely matched acquisitions are incorporated into a multi-slice, multi-average data set with increasing SNR over time. In-plane translations of the coronary artery can be measured and compensated for each accepted acquisition before combination with the other acquisitions. RESULTS: CMRA was performed on six volunteers, with improved SNR and minimal motional blurring. In some cases, breath holding could be dispensed with completely and the average respiratory position used as a reference. CONCLUSION: BACSPIN provides a promising method for CMRA with improved SNR and limited breath-holding requirements.

Coronary Vessels↗

Multislice breath-hold spiral magnetic resonance coronary angiography in patients with coronary artery disease: effect of intravascular contrast medium.

PURPOSE: First, to apply a breath-hold multislice 2D spiral magnetic resonance (MR) approach in patients acquiring within 16 heartbeats (acquisition window, 116 msec) a 10-mm-thick stack of four slices (resolution, 1.3 x 1.3 mm(2)); and second, to evaluate the effect of an intravascular Fe-based contrast medium (CM) on a signal-to-noise ratio (SNR) and a contrast-to-noise ratio (CNR). MATERIALS AND METHODS: In each patient one or two coronary arteries were imaged prior to and following cumulative doses of 0.25, 0.5, and 0.75 mg of Fe/kg of body weight (bw) of an intravascular CM (CLARISCAN trade mark, Nycomed-Amersham, Princeton, NJ, USA) containing ultrasmall superparamagnetic iron oxide (USPIO) particles. RESULTS: On precontrast maximum intensity projection (MIP) images generated from the stack of slices, 10 and 11 stenoses of 12 stenoses confirmed by coronary angiography were detected by readers 1 and 2, respectively. SNR and CNR in the coronary arteries peaked at 0.50 mg of Fe/kg of bw, yielding a slight increase of 15.5% and 18.4%, respectively (P < 0.05 vs. precontrast), which did not improve detection of coronary artery stenoses. CONCLUSION: The presented multislice spiral approach allows display of coronary anatomy in MIP formats for convenient display of coronary stenoses. The pulse sequence did not benefit from an intravascular USPIO-based CM, since little improvement in SNR and CNR was achieved.

Aged↗

FIESTA-ET: high-resolution cardiac imaging using echo-planar steady-state free precession.

This work describes a technique that combines multishot echo-planar imaging (EPI) with steady-state free precession (SSFP, also known as TrueFISP, FIESTA, and balanced FFE) for multislice, cine MR imaging of the heart. Unlike recently reported methods, the technique presented here (FIESTA-ET) is high-resolution and does not require offline reconstruction or postprocessing. It is therefore suitable for use on standard clinical scanners. FIESTA-ET was compared with conventional FIESTA imaging in 10 volunteers and quantitative analyses of myocardial signal-to-noise ratios (SNR) and ventricular volumes were performed. While providing comparable image quality, FIESTA-ET required half the acquisition time per slice of conventional FIESTA. Because multiple slices could be imaged in a single breathhold, the entire heart could be scanned in less than 2 min. Although the FIESTA-ET images exhibited an unexpected increase (P < 0.0005) in myocardial SNR of 16% over FIESTA, the volumetric measurements showed excellent correlation.

Adult↗