PubMed Health⌕ Search

Biomedical subjects

Maojun Gong

Publications and source records attributed to Maojun Gong.

3 recordsLinked to original sources

Unlimited-volume electrokinetic stacking injection in sweeping capillary electrophoresis using a cationic surfactant.

Sweeping is an effective and convenient way for online sample preconcentration in micellar electrokinetic chromatography. The usual procedure includes a hydrodynamic injection step carried out by applying pressure to the sample vial followed by the subsequent sweeping and separation processes. The injected sample volume is limited by the dimensions of the capillary because a part of the capillary has to be left free of sample solution for the subsequent sweeping and separation steps. In addition, when a short capillary, such as 4-10 cm, is used for sweeping, the injected sample volume is small even if the entire capillary is filled with sample solution. To solve this problem, an electrokinetic stacking injection (EKSI) scheme was developed by using a cationic surfactant, dodecyltrimethylammonium bromide, for sweeping in capillary electrophoresis. An experimental model was proposed, and the entire process was theoretically analyzed. According to the theoretical discussion, the optimal conditions for two model analytes, 5-carboxyfluorescein (5-FAM) and sodium fluorescein (FL), were experimentally determined. The injected sample plug lengths for 5-FAM and FL under 20.1 kV for 60 min were experimentally estimated as 836 and 729 cm, corresponding to 28- and 24-fold the effective capillary length, respectively. The EKSI scheme resulted in increased detection factors for 5-FAM and FL of 4.5 x 10(3) and 4.0 x 10(3) using 60-min injection relative to a traditional pressure injection.

Cations↗

On-line sample preconcentration by sweeping with dodecyltrimethylammonium bromide in capillary zone electrophoresis.

On-line sample preconcentration of oligonucleotides with a new sweeping carrier was developed by using dodecyltrimethylammonium bromide (DTAB) below the critical micelle concentration (CMC). The sweeping results with DTAB below and above the CMC were compared. The use of DTAB below the CMC benefits the preconcentration of the oligonucleotides, while the use of DTAB above the CMC is good for hydrophobic small molecules. The factors affecting the sweeping results were optimized and this method was evaluated by constructing calibration curves for thrombin aptamers. The sweeping scheme produced a 112-fold sensitivity enhancement for the oligonucleotides relative to that run in a running buffer without DTAB. The sweeping method developed here can be a good reinforcement of the preconcentration scheme by sweeping when less-hydrophobic analytes or large negatively-charged molecules need to be preconcentrated.

Acetonitriles↗

On-line sample preconcentration using field-amplified stacking injection in microchip capillary electrophoresis.

Previous reports describing sample stacking on microchip capillary electrophoresis (microCE) have regarded the microchip channels as a closed system and treated the bulk flow as in traditional capillary electrophoresis. This work demonstrates that the flows arising from the intersection should be investigated as an open system. It is shown that the pressure-driven flows into or from the branch channels due to bulk velocity mismatch in the main channel should not be neglected but can be used for liquid transportation in the channels. On the basis of these concepts, a sample preconcentration scheme was developed in a commercially available single-cross glass chip for microCE. Similar to field-amplified stacking injection in traditional CE, a low conductivity sample buffer plug was introduced into the separation channel immediately before the negatively charged analyte molecules were injected. The detection sensitivity was improved by 94-, 108-, and 160-fold for fluorescein-5-isothiocyanate, fluorescein disodium, and 5-carboxyfluorescein, respectively, relative to a traditional pinched injection. The calibration curves for fluorescein and 5-carboxyfluorescein demonstrated good linearity in the concentration range (1-60 nM) investigated with acceptable reproducibility of migration time and peak height and area ratios (4-5% RSD). This preconcentration scheme will be of particular significance to the practical use of microCE in the emerging miniaturized analytical instrumentation.

Buffers↗