PubMed Health⌕ Search

Biomedical subjects

María C Moreno-Bondi

Publications and source records attributed to María C Moreno-Bondi.

6 recordsLinked to original sources

Direct extraction of penicillin G and derivatives from aqueous samples using a stoichiometrically imprinted polymer.

A molecularly imprinted polymer (MIP) prepared using penicillin G procaine salt as the template (PENGp) and a stoichiometric quantity of urea-based functional monomer to target the single oxyanionic species in the template molecule has been applied to the development of a molecularly imprinted solid-phase extraction (MISPE) procedure for the selective preconcentration of beta-lactam antibiotics (BLAs) from environmental water samples. Various parameters affecting the extraction efficiency of the polymer have been evaluated to achieve the selective preconcentration of the antibiotics from aqueous samples and to reduce nonspecific interactions. This resulted in an MISPE-HPLC method allowing the direct extraction of the analytes from the sample matrix with a selective wash using just 10% (v/v) organic solvent. On the basis of UV detection only, the method showed good recoveries and precision, ranging between 93% and 100% (RSD 3.8-8.9%, n = 3) for tap water and between 90% and 100% (RSD 4.2-9.1%, n = 3) for river water fortified with 30 or 60 microg L-1 (50 mL samples) penicillin G, penicillin V, nafcillin, oxacillin, cloxacillin, and dicloxacillin, suggesting that this MIP can be successfully applied to the direct preconcentration of BLAs in environmental water samples.

Chromatography, High Pressure Liquid↗

Molecularly imprinted polymers applied to the clean-up of zearalenone and alpha-zearalenol from cereal and swine feed sample extracts.

A molecularly imprinted polymer prepared using 1-allylpiperazine (1-ALPP) as the functional monomer, trimethyltrimethacrylate (TRIM) as the crosslinker and the zearalenone (ZON)-mimicking template cyclododecanyl-2,4-dihydroxybenzoate (CDHB) has been applied to the clean-up and preconcentration of this mycotoxin (zearalenone) and a related metabolite, alpha-zearalenol (alpha-ZOL), from cereal and swine feed sample extracts. The extraction of ZON and alpha-ZOL from the food samples was accomplished using pressurized liquid extraction (PLE) with MeOH/ACN (50:50, v/v) as the extraction solvent, at 50 degrees C and 1500 psi. The extracted samples were cleaned up and preconcentrated through the MIP cartridge and analyzed using HPLC with fluorescence detection (lambda (exc)=271/ lambda (em)=452 nm). The stationary phase was a polar endcapped C18 column, and ACN/MeOH/water 10/55/35 (v/v/v, 15 mM ammonium acetate) at a flow rate of 1.0 mL min(-1) was used as the mobile phase. The method was applied to the analysis of ZON and alpha-ZOL in wheat, corn, barley, rye, rice and swine feed samples fortified with 50, 100 and 400 ng g(-1) of both mycotoxins, and it gave recoveries of between 85 and 97% (RSD 2.1-6.7%, n=3) and 87-97% (RSD 2.3-5.6%, n=3) for alpha-ZOL and ZON, respectively. The method was validated using a corn reference material for ZON.

Animal Feed↗

Molecular engineering of fluorescent penicillins for molecularly imprinted polymer assays.

The interaction of seven novel fluorescent labeled beta-lactams with a library of six polymer materials molecularly imprinted (MI) with penicillin G (PenG) has been evaluated using both radioactive and fluorescence competitive assays. The highly fluorescent competitors (emission quantum yields of 0.4-0.95) have been molecularly engineered to contain pyrene or dansyl labels while keeping intact the 6-aminopenicillanic acid moiety for efficient recognition by the cross-linked polymers. Pyrenemethylacetamidopenicillanic acid (PAAP) is the tagged antibiotic that provides the highest selectivity when competing with PenG for the specific binding sites in a MI polymer prepared with methacrylic acid and trimethylolpropane trimethacrylate (10:15 molar ratio) in acetonitrile in the presence of PenG. Molecular modeling shows that recognition of the fluorescent analogues of PenG by the MI material is due to a combination of size and shape selectivity and demonstrates how critical the choice of label and tether chain is. PAAP has been applied to the development of a fluorescence competitive assay for PenG analysis with a dynamic range of 3-890 muM in 99:1 acetonitrile-water solution. Competitive binding studies demonstrate various degrees of cross-reactivity for some antibiotics derived from 6-aminopenicillanic acid, particularly amoxicillin, ampicillin, and penicillin V (but not oxacillin, cloxacillin, dicloxacillin, or nafcillin). Other antibiotics, such as chloramphenicol, tetracycline, or cephapirin, do not compete with PAAP for binding to the imprinted polymer. The MI assay has successfully been tested for PenG analysis in a pharmaceutical formulation.

Binding, Competitive↗

Development of a novel and automated fluorescent immunoassay for the analysis of beta-lactam antibiotics.

An automated immunosensor for the rapid and sensitive analysis of penicillin type beta-lactam antibiotics has been developed and optimized. An immunogen was prepared by coupling the common structure of the penicillanic beta-lactam antibiotics, i.e., 6-aminopenicillanic acid to keyhole limpet hemocyanin. Polyclonal antibodies raised in rabbits after immunization with this conjugate have been applied for the development of a competitive fluoroimmunoassay (FIA), using a novel fluorescent penicillin {[2S,5R,6R]-3,3-dimethyl-7-oxo-6-[(pyren-1ylacetyl)amino]-4-thia-1-azabicyclo[3.2.0]heptane-2-carboxilic acid, PAAP} as the tracer and penicillin G as the reference antibiotic. Protein A/G covalently bound to an azlactone-activated polymeric support was used for the orientated capture of the antibody-antigen immunocomplexes. Upon desorption from the immunosupport, the emission signal generated by the PAAP-Ab complexes is related to the antibiotic concentration in the sample. The 50% binding inhibition concentration of penicillin G standard curves was at 30 ng mL(-)(1) with a detection limit (10% binding inhibition) of 2.4 ng mL(-)(1) and a dynamic range from 6.0 to 191 ng mL(-)(1) (20-80% binding inhibition) penicillin G. The generic nature of the antiserum was shown by good relative cross-reactivities with penicillin type beta-lactam antibiotics such as amoxicillin (50%), ampicillin (47%), and penicillin V (145%) and a lower response to the isoxazolyl penicillins such as oxacillin, cloxacillin, and dicloxacillin. No cross-reactivity was obtained for cephalosporin type beta-lactam antibiotics (cephapirin), cloramphenicol, or fluoroquinolones (enrofloxacin and ciprofloxacin). The total analysis time was 23 min per determination, and the immunoreactor could be reused for more than 200 cycles without significant loss of activity. The immunosensor has been successfully applied to the direct analysis of penicillin G and amoxicillin in spiked influent and effluent sewage treatment plant water samples with excellent recoveries (mean values for penicillin G and amoxicillin, 99 and 105%, respectively). Results displayed by comparative analysis of the immunosensor with a chromatographic procedure for penicillins showed excellent agreement between both methods.

Anti-Bacterial Agents↗

Analysis of zearalenone in cereal and Swine feed samples using an automated flow-through immunosensor.

The development of a sensitive flow-though immunosensor for the analysis of the mycotoxin zearalenone in cereal samples is described. The sensor was completely automated and was based on a direct competitive immunosorbent assay and fluorescence detection. The mycotoxin competes with a horseradish-peroxidase-labeled derivative for the binding sites of a rabbit polyclonal antibody. Control pore glass covalently bound to Prot A was used for the oriented immobilization of the antibody-antigen immunocomplexes. The immunosensor shows an IC(50) value of 0.087 ng mL(-1) (RSD = 2.8%, n = 6) and a dynamic range from 0.019 to 0.422 ng mL(-1). The limit of detection (90% of blank signal) of 0.007 ng mL(-1) (RSD = 3.9%, n = 3) is lower than previously published methods. Corn, wheat, and swine feed samples have been analyzed with the device after extraction of the analyte using accelerated solvent extraction (ASE). The immunosensor has been validated using a corn certificate reference material and HPLC with fluorescence detection.

Animal Feed↗

Continuous solid-phase extraction and preconcentration of bisphenol A in aqueous samples using molecularly imprinted columns.

A bisphenol A (BPA) molecularly imprinted polymer, the composition of which was optimised using a chemometric approach, has been applied to the selective preconcentration of the template from aqueous samples. The selectivity of the polymer toward BPA and related compounds was evaluated chromatographically. The BPA-imprinted polymer was packed in a column and used for continuous on-column solid-phase extraction (MISPE) of aqueous samples followed by subsequent analysis by HPLC with fluorescence detection of the eluted fractions. The composition of the washing solvent applied in the MISPE procedure was optimised to favour the specific interactions of the MIP with BPA and to remove the non-selectively bound matrix components. The MISPE method has proven to be effective for selective preconcentration of BPA in aqueous samples (recoveries >84% obtained in the eluate for 10-100 mL sample volumes) enabling detection and quantification limits of 1.0 and 3.3 ng mL(-1), respectively (based on 25 mL sample size). Analytical recoveries were between 92 and 101% for river water samples spiked with known amounts of BPA (30, 60, and 80 ng mL(-1)); relative standard deviations (RSD) were lower than 5.0%.

Benzhydryl Compounds↗