PubMed Health⌕ Search

Biomedical subjects

María Teresa Tena

Publications and source records attributed to María Teresa Tena.

At least 19 recordsLinked to original sources

Determination of ethylphenols in wine by in situ derivatisation and headspace solid-phase microextraction-gas chromatography-mass spectrometry.

Contamination by Brettanomyces is a frequent problem in many wineries that has a dramatic effect on wine aroma and hence its quality. The yeast Brettanomyces/Dekkera is involved in the formation of three important volatile ethylphenols-4-ethylphenol, 4-ethylguaiacol and 4-ethylcatechol-that transmit an unpleasant aroma to wine that has often been described as 'medicinal', 'stable' or 'leather'. This study proposes an in situ derivatisation and headspace solid-phase microextraction- gas chromatography coupled to mass spectrometry method to determine the three ethylphenols in red Brettanomyces-tainted wines. The most important variables involved in the derivatisation (acetic anhydride and base concentration) and the extraction (extraction temperature and salt addition) processes were optimised by experimental design. The optimal conditions using 4 mL of wine in 20-mL sealed vials were 35 muL of acetic anhydride per millilitre of wine, 1 mL of 5.5% potassium carbonate solution and 0.9 g of sodium chloride and the extraction was performed with a divinylbenzene-carboxen-poly(dimethylsiloxane) fibre at 70 degrees C for 70 min. Then, the performance characteristics were established using wine samples spiked with the ethylphenols. For all compounds, the detection limits were below the odour threshold reported in the literature and they were between 2 and 17 microg L(-1) for 4-ethylguaiacol and 4-ethylphenol, respectively. Intermediate precision (as relative standard deviation) was acceptable, with values ranging from 0.3 to 12.1%. Finally, the method was applied in the analysis of aged Brettanomyces-tainted wines.

Journal Article↗

Comparison of three gas chromatography methods for the determination of slip agents in polyethylene films.

Polymers require the use of some slip agents, such as oleamide and erucamide, in order to reduce their friction coefficient and to make films easier to handle. In this communication, three analytical methods consisting in pressurized liquid extraction (PLE) and gas chromatography (GC) are used to determine oleamide and erucamide in polyethylene films. The sample was extracted with pure isopropanol (two times) at 105 degrees C for 16 min. Then, the liquid extract containing oleamide and erucamide was analyzed by GC and three different detection systems: flame ionization detector (FID), thermoionic selective detector (TSD) and ion-trap mass spectrometry detector (MSD). Oleamide and erucamide were separated using a 30 m x 0.25 mm (I.D.) 5% phenyl-95% dimethyl-polysiloxane capillary column in 12 min. The chromatographic methods were characterized and compared in terms of repeatability, linearity and sensitivity. The GC-FID and GC-TSD methods were linear up to about 60 microg ml(-1), whereas the linear range for the GC-MSD method was shorter, from 20.5 to 42 microg ml(-1). LODs identified with GC-MSD were two times higher than those identified with the other two methods. Repeatability values (expressed as relative standard deviation) of less than 2.5% were found for FID and TSD but they were above 10% for MSD. Finally, each method was applied to determine the content of erucamide and oleamide in several polyethylene films and the results obtained were compared with those obtained from the nitrogen content measured by pyrolysis and gas-phase chemiluminescence. No significant differences were observed between the results of the methods.

Chromatography, Gas↗

Fibre selection based on an overall analytical feature comparison for the solid-phase microextraction of trihalomethanes from drinking water.

This paper describes the optimization of solid-phase microextraction (SPME) conditions for three different fibres (Carboxen-polydimethylsiloxane (CAR-PDMS), divinylbenzene-Carboxen-polydimethylsiloxane (DVB-CAR-PDMS) and polydimethylsiloxane-divinylbenzene (PDMS-DVB)) used to determine trihalomethanes (THMs) in water by headspace solid-phase microextraction and gas chromatography (HS-SPME-GC). The influence of temperature and salting-out effect was examined using a central composite design for each fibre. Extraction time was studied separately at the optimum values found for temperature and sodium chloride concentration (40 degrees C and 0.36g mL-1). The HS-SPME-GC-MS method for each fibre was characterised in terms of linearity, detection (LOD) and quantification (LOQ) limits and repeatability. The fibre PDMS-DVB was selected as it provided a broader linear range, better repeatability and lower detection and quantification limits than the others, particularly CAR-PDMS fibre. The accuracy of the proposed method using the PDMS-DVB fibre was checked by a recovery study in both ultrapure and tap water. A blank analysis study showed the absence of memory effects for this fibre. The reproducibility (expressed as a percentage of relative standard deviation) was 6-11% and the detection limits were between 0.078 and 0.52microgL-1 for bromoform and chloroform, respectively. Finally, the method was applied to determine THM concentration in two drinking water samples.

Gas Chromatography-Mass Spectrometry↗

Determination of oleamide and erucamide in polyethylene films by pressurised fluid extraction and gas chromatography.

A pressurized fluid extraction (PFE) and gas chromatography-flame ionization detection (GC-FID) method is proposed to determine the slip agents in polyethylene (PE) films. The study of PFE variables was performed using a fractional factorial design (FFD) for screening and a central composite design (CCD) for optimizing the main variables obtained from the Pareto charts. The variables that were studied include temperature, static time, percentage of cyclohexane and the number of extraction cycles. The final condition selected was pure isopropanol (two times) at 105 degrees C for 16min. The recovery of spiked oleamide and erucamide was around 100%. The repeatability of the method was between 9.6% for oleamide and 8% for erucamide, expressed as relative standard deviation. Finally, the method was applied to determine oleamide and erucamide in several polyethylene films and the results were statistically equal to those obtained by pyrolysis and gas-phase chemiluminescence (CL).

Analysis of Variance↗

Determination of volatile oak compounds in aged wines by multiple headspace solid-phase microextraction and gas chromatography-mass spectrometry (MHS-SPME-GC-MS).

Multiple headspace solid-phase microextraction (MHS-SPME) with gas chromatography-mass spectrometry is proposed for quantification of nine volatile oak compounds in aged wines. These compounds are formed and extracted by wine when it is matured in oak barrels and are responsible for particular organoleptic properties and the high quality of these wines. Some important variables of the extraction process, for example volume of sample and extraction time, were studied. Extraction of 50 microL wine was performed with a divinylbenzene-Carboxen-polydimethylsiloxane fibre at 55 degrees C for 60 min. For calibration the same conditions were used, except that the wine was substituted by 50 microL of a standard solution in synthetic wine. The linearity, detection limits, and repeatability of the method were determined by use of standard solutions in synthetic wine. Detection limits were between 0.01 and 10 microg L(-1) (for eugenol and furfural, respectively) and repeatability, expressed as relative standard deviation, was from 2 to 6%. The method was used to analyse six red wines and the concentrations obtained were statistically compared with those obtained by the standard addition method for the same wines.

Gas Chromatography-Mass Spectrometry↗

Determination of volatile oak compounds in wine by headspace solid-phase microextraction and gas chromatography-mass spectrometry.

A headspace solid-phase microextraction (HS-SPME) and gas chromatography (GC) coupled to mass spectrometry (MS) method was developed to identify and quantify 14 volatile oak compounds in aged red wines. The most important HS-SPME variables were optimised by experimental design technique in order to improved the extraction process. The selected conditions were: 10 mL of sample in 20 mL sealed vials with addition of 30% of sodium chloride (saturated solution), divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS) fibre, 10 min of pre-incubation time, 70 degrees C of temperature and 60 min of extraction time without agitation. The features of the method were established for the studied compounds in terms of linear range, slope and intercept of the calibration graphs, detection and quantification limits and repeatability. For all compounds detection limits were below their threshold levels and repeatability, in terms of relative standard deviation, was good, with values between 3 and 11%. Finally, the method was applied to the analysis of six aged red wines by both internal standard and standard addition calibration methods. The concentrations obtained with both methods were statistically compared.

Gas Chromatography-Mass Spectrometry↗

Determination of 2,4,6-trichloroanisole and guaiacol in cork stoppers by pressurised fluid extraction and gas chromatography-mass spectrometry.

This paper describes the development of an analytical method consisting of pressurised fluid extraction (PFE) and gas chromatography-mass spectrometry (GC-MS) using experimental designs to determine two volatile compounds in naturally-tainted cork stoppers. The target analytes, 2,4,6-trichloroanisole (2,4,6-TCA) and guaiacol, are involved in the cork taint of wine. First, a Plackett-Burman experimental design was carried out in order to determine the significant experimental parameters affecting the PFE process, and then a central composite design was used to optimise these significant parameters. Once the method had been optimised, the influence of the number of extraction cycles was studied. The method was applied to determine the concentration of 2,4,6-TCA and guaiacol in three cork samples, and the results were compared with the ones obtained by multiple headspace-solid-phase microextraction (MHS-SPME) and by Soxhlet extraction.

Anisoles↗

Headspace solid-phase microextraction gas chromatography-mass spectrometry method for the identification of cosmetic ingredients causing delamination of packagings.

A headspace solid-phase microextraction gas chromatography-mass spectrometry (HS-SPME-GC-MS) method using a 75 microm Carboxen polydimethylsiloxane fibre was used to identify volatile compounds of cosmetic formulations responsible for causing loss of adhesion between layers of multilayer packagings. To obtain the sample, the sachet with the product was kept in an oven at 40 degrees C in order to favour the migration of the aggressive compounds to the inner layers. Then the sachet was manually delaminated and the aluminium/polyester and polyethylene layers were analysed. The cosmetic product was also analysed by HS-SPME-GC-MS. Several compounds used in the cosmetic industry such as perfumes or fixing agents were detected in the inner layers of the laminated material, showing the migration of them through the layer in contact with the product (polyethylene). Phenoxy ethanol, beta-linalool, menthol and p-propenylanisole are suspected to be responsible for the loss of adhesion. In order to provide a complete overview of the cause of the aforementioned phenomenon, the packaging material was exposed to the cosmetic products in order to measure the decrease of the adhesion strength with time. It was observed that the product with a higher phenoxy ethanol concentration caused a higher loss of adhesion strength. The results obtained showed that this method is suitable for identifying aggressive compounds in cosmetic products, as well as for giving prior information about which products may be problematic for packaging in sachets.

Absorption↗

Experimental design approach for the optimisation of pressurised fluid extraction of additives from polyethylene films.

A pressurised fluid extraction (PFE) and normal-phase-high performance liquid chromatography (NP-HPLC) method is proposed for the determination of additives in polyethylene films. The study of PFE variables was performed using a Plackett-Burman (PB) experimental design for screening and a central composite design (CCD) for optimising the main variables obtained from the Pareto charts. The studied variables were: temperature, time, cyclohexane (CHx) and tetrahydrofuran (THF) as modifiers, flush volume and extraction cycles, and an isopropanol:CHx (92.5:7.5) mixture twice at 105 degrees C for 15 min were the final conditions selected. The additives in the PFE extracts were separated by NP-HPLC using a silica column and a gradient n-hexane:dichloromethane:acetonitrile mobile phase. Additive solubility is higher in normal-phase solvents; thus, their separation can be carried out at room temperature. Finally, the method was applied to determine additives in several polyethylene films.

Polyethylene↗

Determination of odour-causing volatile organic compounds in cork stoppers by multiple headspace solid-phase microextraction.

Multiple headspace solid-phase microextraction (MHS-SPME) coupled with gas chromatography-mass spectrometry has been applied in order to determine 2,4,6-trichloroanisole (2,4,6-TCA), guaiacol, 1-octen-3-ol and 1-octen-3-one in three samples of cork stoppers. These compounds are responsible for cork taint in wine and can modify the organoleptic properties of bottled wine. Variables such as temperature, addition of water, extraction time, and amount of cork were studied. The extractions were performed with a 50/30 microm divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS) fibre for 45 min at 100 degrees C using 20 mg of cork. For calibration, 50 microL of VOC aqueous solutions were used and the extraction were carried out for 45 min at 75 degrees C. The limits of detection of the method expressed as ng of VOC per g of cork were 0.3 for 2,4,6-TCA, 7.5 for guaiacol, 1.7 for 1-octen-3-one and 1.9 for 1-octen-3-ol. Relative standard deviation of replicate samples was less than 10%. Significant losses of analytes were observed when the samples were ground at room temperature. Finally, a recovery study was performed and the MHS-SPME results were validated using Soxhlet extraction results.

Anisoles↗

Analysis of aged red wine pigments by capillary zone electrophoresis.

Red wines of different ages (1-14 years) were analysed by Capillary zone electrophoresis (CZE). Pigments were separated using a fused silica capillary with an effective length of 56 cm and an internal diameter of 75 cm. Disodium tetraborate at 50 mM with a pH of 9.4 was used as buffer solution with methanol as modifier. Electrophoregrams were recorded at 280, 520 and 599 nm and spectra were measured from 200 to 599 nm using a diode array detector. Several differences in the CZE signals obtained for different aged wines were observed, as well as between red and white wines. The signals of a group of seven peaks increased in mature wines. A decrease in free anthocyanins was also identified in aged wine. The migration times of these compounds corresponded to charge/size ratios higher than those of free anthocyanins, and their spectra suggested combinations of anthocyanins with flavanols or tannins. The global CZE response of these pigmented polyphenolic polymers was linearly correlated with the spectrophotometric determination of polymeric pigments (96%) and age (92%).

Electrophoresis, Capillary↗

Determination of benzene, toluene, ethylbenzene and xylenes in soils by multiple headspace solid-phase microextraction.

Multiple headspace-solid phase microextraction (MHS-SPME) is a recently developed technique for the quantification of analytes in solid samples that avoids the matrix effect. This method implies several consecutive extractions from the same sample. In this way, the total area corresponding to complete extraction can be directly calculated as the sum of the areas of each individual extraction when the extraction is exhaustive, or through a mathematical equation when it is not exhaustive. In this paper, the quantitative determination of benzene, toluene, ethylbenzene and xylene isomers (BTEX) in a certified soil (RTC-CRM304, LGC Promochem) and in a contaminated soil by multiple HS-SPME coupled to a gas chromatography-flame ionisation detector (GC-FID) is presented. BTEX extraction was carried out using soil suspensions in water at 30 degrees C with a 75 microm carboxen-polydimethylsiloxane (CAR-PDMS) fibre and calibration was carried out using aqueous BTEX solutions at 30 degrees C for 30 min with the same fibre. BTEX concentration was calculated by interpolating the total peak area found for the soils in the calibration graphs obtained from aqueous solutions. The toluene, ethylbenzene, o-xylene and m,p-xylene concentrations obtained were statistically equal to the certified values.

Benzene↗

Evaluation of multiple solid-phase microextraction as a technique to remove the matrix effect in packaging analysis for determination of volatile organic compounds.

Multiple solid-phase microextraction (SPME) is an useful technique for the direct quantification of solid samples removing any matrix effect. The volatile organic compounds formed in the extrusion-coating process of multilayer packaging materials have already been quantified by multiple HS-SPME coupled to gas chromatography (GC)-mass spectrometry (MS) using volatile organic compound (VOC) solutions in hexadecane for calibration. In this article, water is proposed as solvent to prepare the calibration solutions because it provides a shorter calibration time, better linearity, better reproducibility, and lower detection limits than hexadecane. Besides, the extraction of VOCs from aqueous solutions is exhaustive and avoids the extrapolations needed to calculate the total peak areas, as they can be calculated as the sum of the individual areas of each extraction. Finally, it is checked whether the two solvents provide the same mean values for the total peak areas.

Gas Chromatography-Mass Spectrometry↗

Headspace solid-phase microextraction-gas chromatography-mass spectrometry applied to quality control in multilayer-packaging manufacture.

A method based on headspace solid-phase microextraction-gas chromatography-mass spectrometry is proposed for the quality control of multilayer packaging and its manufacturing process. Volatile organic compounds (VOCs) are produced in the manufacturing process of the packaging. They can cause organoleptic problems or modify the properties of the packaging depending on the nature and the amount of the VOCs formed. The quantification using packaging samples with a known VOC concentration for the calibration is proposed in order to reduce the analysis time, and the method is validated using a statistical test. Finally, the method is applied to the determination of odour-responsible compounds in multilayer packaging samples obtained under different extrusion-coating conditions, i.e. type of extruder, type of polymer and extrusion speed.

Calibration↗

Multiple headspace solid-phase microextraction for the quantitative determination of volatile organic compounds in multilayer packagings.

The theory of multiple headspace solid-phase microextraction (HS-SPME) and a method based on multiple HS-SPME for the quantitative determination of volatile organic compounds (VOCs) in packaging materials is presented. The method allows the direct analysis of solid samples without using organic solvents to extract analytes. Multiple headspace solid-phase microextraction is a stepwise method proposed to eliminate the influence of the sample matrix on the quantitative analysis of solid samples by HS-SPME. Different amounts of packaging and different volumes of standard solution were studied in order to remove a substantial quantity of analytes from the headspace at each extraction and obtain the theoretical exponential decay of the peak area of the four successive extractions and, thus, the total area was calculated from these four extractions. In addition, two fibres were compared: carboxen-polydimethylsiloxane (CAR-PDMS) and divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS), as they showed differences in the linearity of the exponential decay with the number of extractions depending on the compound. The CAR-PDMS fibre was better for the VOCs with a low molecular mass, whereas the DVB-CAR-PDMS fibre was better for the VOCs with a high molecular mass. Finally, the method was characterised in terms of linearity, detection limit and reproducibility and applied to analyse four multilayer packaging samples with different VOCs contents.

Organic Chemicals↗

Development and validation of a capillary zone electrophoresis method for the quantitative determination of anthocyanins in wine.

A capillary zone electrophoresis (CZE) method is proposed for the quantitative determination of anthocyanins in wine as an alternative to high-performance liquid chromatography. The CZE separation was carried out using a 46 cm (effective length) x 75 microm I.D. fused-silica capillary at 10 degrees C and a 50 mM sodium tetraborate buffer at pH 8.4 with 15% of methanol as modifier. A voltage of 25 kV and a hydrodynamic injection of 300 mbar s were used. The electropherograms were recorded at 599 nm. It was found that SO2 (antibacterial and antioxidant agent added to wine during its production) increased the absorbance of anthocyanins at 599 nm in a basic medium. Therefore, a concentration of 250 mg/l of SO2 was added to the samples and the calibration solution before the analysis in order to avoid errors by this matrix effect. The analytical response was linear (R=0.998) between 10 and 700 microg/ml of malvidin-3-O-glucoside. The limit of detection and the reproducibility (as a relative standard deviation, n=11) were 1 microg/ml and 1.5%, respectively. Finally, the CZE method was validated by the analysis of synthetic wine samples (errors less than 8%) and by the comparison of the results obtained in the analysis of different monovarietal wines by CZE with those obtained by the standard HPLC method. In this comparison, a good correlation (R=0.998) with a slope of 1.005+/-0.044 and an intercept of -0.752+/-6.690 was obtained for malvidin-3-O-glucoside.

Anthocyanins↗

Direct quantitation of volatile organic compounds in packaging materials by headspace solid-phase microextraction-gas chromatography-mass spectrometry.

The quantification of volatile organic compounds (VOCs) in flexible multilayer packaging materials using headspace solid-phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) was studied. The analytes imclude 22 compounds such as aldehydes. ketones, carboxylic acids and hydrocarbons formed by thermooxidative degradation of polyethylene during the extrusion coating process in the manufacture of the packaging, and many of them are involved in the unpleasant and undesirable odour of these materials. External standard calibration using a solution of the analytes in an appropriate solvent was the first approach studied. Aqueous solutions of the analytes provided low reproducibility and the reduction of aldehydes to alcohols under the HS-SPME conditions. Hexadecane was chosen as the solvent since its polarity is similar to that of polyethylene and its volatility is lower than that of the analytes. However, hexadecane should be added to the sample before the analysis as it modifies the absorption capacity of the fibre. A 75-microm Carboxen-poly(dimethylsiloxane) fibre was used to extract the VOCs from the headspace above the packaging in a 15-ml sealed vial at 100 degrees C after 5 min of preincubation. The influence of the extraction time on the amount extracted was studied for a standard solution of the analytes in hexadecane, together with the influence of the volume of the standard solution and the amount of the sample placed in the vial. Standard addition and multiple HS-SPME were also studied as calibration methods and the results obtained in the quantitative analysis of a packaging material were compared.

Calibration↗

Development of a headspace solid-phase microextraction-gas chromatography-mass spectrometry method for the identification of odour-causing volatile compounds in packaging materials.

A method for the identification of volatile organic compounds in packaging materials is presented in this study. These compounds are formed by thermooxidative degradation during the extrusion coating process in the manufacture of packaging. Headspace solid-phase microextraction (HS-SPME) was used as sample preparation technique prior to the determination of the volatile organic compounds by gas chromatography-mass spectrometry (GC-MS). The effects of extraction variables, such as the type of fibre, the incubation temperature, the pre-incubation time, the size of the vial and the extraction time on the amounts of the extracted volatile compounds were studied. The optimal conditions were found to be: carboxen-polydimethylsiloxane 75 microm fibre, 5 min of pre-incubation time, 100 degrees C of incubation temperature, 20-ml vial, and 15 min of extraction time. The chromatograms obtained by HS-SPME and static headspace extraction were compared in order to show that the HS-SPME method surpasses the static headspace method in terms of sensitivity. Twenty-five compounds were identified including carbonyl compounds (such as 3-methyl-butanal, 3-heptanone or octanal), carboxylic acids (such as pentanoic acid or hexanoic acid) known as odour causing compounds and hydrocarbons (such as decane, undecane or dodecane). Finally, the method was applied to different packaging samples (one odour-unacceptable, two odour-acceptable, and three odourless samples) and to the raw materials in order to find out the odour-responsible volatile organic compounds and their source.

Food Packaging↗