Impact of intrascalar blood on hearing.

OBJECTIVE/HYPOTHESIS: The objective of this controlled animal study was to evaluate the effects of intrascalar blood on hearing. MATERIAL AND METHODS: Eight guinea pigs underwent intrascalar administration of their own blood in one ear and control solution in the contralateral ear. Solutions were applied through cochleostomy to the scala tympani. Compound action potential (CAP) thresholds were determined before administration and at different intervals for 2 months thereafter. RESULTS: Immediate deterioration of thresholds was seen mainly in the high-frequency range, averaging 27 dB and 20 dB in the study and control groups, respectively. At day 3, threshold shifts recovered in the control group but remained in the low-frequency range in the study group. An extensive recovery was seen in both groups. However, permanent threshold shifts persisted. There was an enhanced shift of thresholds of up to 7 dB in the study group. CONCLUSIONS: Even small amounts of intrascalar blood seem to cause transient and permanent detrimental effects on cochlear function. In procedures involving opening of the otic capsule-like stapes surgery and cochlear implantation with hearing preservation-minimizing surgical blood admixture to intracochlear compartments seems therefore fundamental.

Animals↗

Predicting basal cochlear length for electric-acoustic stimulation.

OBJECTIVE: To assess the feasibility and accuracy of predicting electrode insertion depth necessary in cochlear implantations for electric-acoustic stimulation by means of preoperative high-resolution computed tomography (HRCT). DESIGN: Human temporal bone study with evaluation of cochlear dimensions. SETTING: Tertiary care medical center. METHODS: Eight fresh human temporal bones were scanned, and basal cochlear structures were reconstructed and measured. Standard cochlear implantations with a free-fitting array were performed, and the bones then underwent histologic analysis using a technique that allows sectioning of undecalcified bones. After embedding, all bones underwent conventional radiologic analysis with further insertion measurements. Preimplantation HRCT data were compared with radiologic and histologic data. RESULTS: Preimplantation HRCT-based measurements correlated very well with postimplantation radiologic data. A mean failure of 0.3 mm was found. Mean values for the first 360 degrees ranged from 18.8 to 22.0 mm. CONCLUSIONS: Preimplantation HRCT-based prediction of cochlear implant insertion depths is both feasible and accurate. It is especially useful when aiming for hearing preservation, where insertion depths of 360 degrees are necessary.

Adult↗

Cochlear implantation via the round window membrane minimizes trauma to cochlear structures: a histologically controlled insertion study.

OBJECTIVE: To evaluate cochlear implant trauma to intracochlear structures when inserting the electrode via the round window membrane. MATERIAL AND METHODS: Eight fresh human temporal bones were evaluated histologically after insertion using two types of cochlear implant array. Bones underwent a special fixation and embedding procedure that allowed sectioning of undecalcified bone with the electrode in situ. Insertions depths were evaluated radiologically and histologically. RESULTS: All arrays were found in the scala tympani of the cochlea. Basal trauma could be avoided in all but one specimen. The mean depth of insertion was 382.5 degrees. Apically, only one implanted bone showed cochlear trauma exceeding lifting of the basilar membrane. CONCLUSION: Insertions through the round window membrane were shown to be atraumatic, even in basal cochlear regions. This route of insertion might be very effective for combined electric and acoustic stimulation of the auditory system.

Cochlea↗

Development and evaluation of an improved cochlear implant electrode design for electric acoustic stimulation.

OBJECTIVE: The objective of this study was to assess the intracochlear position and the extent of trauma to cochlear structures using a new prototype electrode carrier (Flex EAS). Special emphasis was placed on the practicality for combined electric and acoustic stimulation of the auditory system. STUDY DESIGN: Human temporal bones were evaluated histologically after insertion of the electrodes, and insertion forces were measured in an acrylic model of the scala tympani. METHODS: 1) Insertion forces with the regular C40+ array and the new electrode prototype were measured in an acrylic model of the scala tympani. 2) Ten human temporal bones were implanted using the same surgical procedure as in vivo. All bones underwent fixation methylmethacrylate embedding to allow cutting of the undecalcified bone with the electrode in situ. In addition, radiography of the implanted devices was performed and correlated to histologic results. Electrode positions and trauma to cochlear structures were then evaluated histologically. RESULTS: All insertions of the new electrode array were performed in the scala tympani of the cochlea. All insertions were atraumatic and covered one cochlear turn. The only effect on cochlear structures that could be observed was a slight lifting of the basilar membrane in the middle turn limited to the tip of the electrode. In three bones, basal trauma, which resulted from the cochleostomy itself, could be observed as well. All neural structures remained intact. CONCLUSIONS: The new electrode prototype provides very good mechanical properties for safe and atraumatic implantation. All criteria for the use in hearing-preservation cochlear implantation for electric and acoustic stimulation were fulfilled. Surgical measures to prevent basal trauma appear to be very important.

Acoustic Stimulation↗

Preservation of basal inner ear structures in cochlear implantation.

The aim of this report was to examine basal trauma in implanted human temporal bones and discuss modified approaches to the basal cochlear turn to avoid destruction of basal cochlear structures. Thirty-three human temporal bones were implanted with four different cochlear implant electrode arrays manufactured by MED-EL using either a caudal approach cochleostomy or round window membrane insertions. All specimens were processed with a special histological technique that allows sectioning of undecalcified bone with the electrode in situ. All bones were evaluated histologically in terms of basal cochlear trauma. Two pathomechanisms of basal trauma could be distinguished and were evaluated separately, buckling of the basal end of the array and trauma by drilling. Using the caudal approach cochleostomy, the total percentage of destructive basal trauma was 48% compared to less than 15% when performing round window membrane insertions. Although it is still unclear whether basal cochlear trauma influences apical cochlear function or not, adapted surgical procedures and no forceful insertion maneuvers should be used when performing cochlear implantations with hearing preservation.

Cochlea↗