Marc L Dickstein

Publications and source records attributed to Marc L Dickstein.

4 recordsLinked to original sources

Single-beat estimation of end-diastolic pressure-volume relationship: a novel method with potential for noninvasive application.

Whereas end-systolic and end-diastolic pressure-volume relations (ESPVR, EDPVR) characterize left ventricular (LV) pump properties, clinical utility of these relations has been hampered by the need for invasive measurements over a range of pressure and volumes. We propose a single-beat approach to estimate the whole EDPVR from one measured volume-pressure (Vm and Pm) point. Ex vivo EDPVRs were measured from 80 human hearts of different etiologies (normal, congestive heart failure, left ventricular assist device support). Independent of etiology, when EDPVRs were normalized (EDPVRn) by appropriate scaling of LV volumes, EDPVRns were nearly identical and were optimally described by the relation EDP = An.EDV (Bn), with An = 28.2 mmHg and Bn = 2.79. V0 (the volume at the pressure of approximately 0 mmHg) was predicted by using the relation V0 = Vm.(0.6 - 0.006.Pm) and V30 by V30 = V0 + (Vm,n - V0)/(Pm/An) (1/Bn). The entire EDPVR of an individual heart was then predicted by forcing the curve through Vm, Pm, and the predicted V0 and V30. This technique was applied prospectively to the ex vivo human EDPVRs not used in determining optimal An and Bn values and to 36 in vivo human, 12 acute and 14 chronic canine, and 80 in vivo and ex vivo rat studies. The root-mean-square error (RMSE) in pressure between measured and predicted EDPVRs over the range of 0-40 mmHg was < 3 mmHg of measured EDPVR in all settings, indicating a good predictive value of this approach. Volume-normalized EDPVRs have a common shape, despite different etiology and species. This allows the entire curve to be predicted by a new method with a potential for noninvasive application. The results are most accurate when applied to groups of hearts rather than to individual hearts.

Algorithms↗

Mechanical unloading during left ventricular assist device support increases left ventricular collagen cross-linking and myocardial stiffness.

BACKGROUND: Left ventricular assist devices (LVADs) induce reverse remodeling of the failing heart except for the extracellular matrix, which exhibits additional pathophysiological changes, although their mechanisms and functional consequences are unknown. METHODS AND RESULTS: Hearts were obtained at transplant from patients with idiopathic dilated cardiomyopathy (DCM) not requiring LVAD support (n=30), patients requiring LVAD support (n=16; LVAD duration, 145+/-33 days), and 5 nonfailing hearts. Left (LV) and right ventricular (RV) ex vivo pressure-volume relationships were measured, and chamber and myocardial stiffness constants were determined. Myocardial tissue content of total and cross-linked collagen, collagen types I and III, MMP-1, MMP-9, TIMP-1, and angiotensin (Ang) I and II were measured. LV size, mass, and myocyte diameter decreased after LVAD compared with DCM without LVAD (P<0.05). Total and cross-linked collagen and ratio of type I to III collagen increased in DCM compared with nonfailing hearts and increased further after LVAD (P<0.05 versus DCM and nonfailing). Concomitantly, chamber and myocardial stiffness increased with LVAD. The ratio of MMP-1 to TIMP-1 increased in DCM and almost normalized after LVAD, favoring decreased collagen degradation. Tissue Ang I and II also increased during LVAD. There was no significant change in the RV of LVAD-supported heart compared with DCM. CONCLUSIONS: LVAD support increases LV collagen cross-linking and the ratio of collagen type I to III, which is associated with increased myocardial stiffness. Decreased tissue MMP-1-to-TIMP-1 ratio (decreased degradation) and increased Ang levels (stimulants of synthesis) are likely mechanisms for these changes. Lack of significant effects on the RV suggest that hemodynamic unloading of the LV (not provided to the RV) might be the primary factor that regulates these extracellular matrix changes.

Adult↗

Transesophageal echocardiography guided placement of a coronary sinus pacing lead.

Cardiac resynchronization therapy for the treatment of medically refractory heart failure requires coronary sinus lead placement for left ventricular pacing. Coronary sinus lead placement is technically difficult with success rates reported between 53% to 98% and implantation times ranging from 90 minutes to 5 hours. We report the use of intraoperative transesophageal echocardiography to guide coronary sinus lead placement when conventional fluoroscopy failed. Transesophageal echocardiography may improve the success rate with coronary sinus lead placement and decrease the operative time required. This should be used with caution, however, as sedation, possible intubation, and esophageal manipulation have potentially morbid consequences in patients with advanced congestive heart failure.

Aged↗