PubMed Health⌕ Search

Biomedical subjects

Marc Van Cauteren

Publications and source records attributed to Marc Van Cauteren.

12 recordsLinked to original sources

Balanced turbo field-echo sequence for MRI of parotid gland diseases.

OBJECTIVE: A balanced turbo field-echo (FE) sequence is a balanced steady-state free precession sequence used for achieving rapid and high imaging. We tested whether this imaging technique is applicable to the diagnosis of parotid gland diseases. CONCLUSION: The balanced turbo FE sequence is a novel alternative MRI technique for the diagnosis of various parotid gland diseases.

Adult↗

MR microimaging of benign and malignant nodes in the neck.

OBJECTIVE: We evaluated the diagnostic criteria of high-resolution MRI in differentiating benign and malignant cervical nodes that were palpable and superficial in the neck. SUBJECTS AND METHODS: We performed MR microimaging on 24 histologically proven metastatic nodes, 14 histologically proven lymphomas, and 35 histologically or clinically proven benign nodes in the necks of 26 patients. The lymph nodes were imaged with T1-weighted spin-echo, fat-suppressed T2-weighted turbo spin-echo, and spin-echo diffusion-weighted echo-planar sequences using a 47-mm microscopy coil. RESULTS: MR microimaging provided high-resolution images of the nodes. Hilar fat was lost in 92%, 79%, and 46% of the metastatic nodes, lymphomas, and benign nodes, respectively. Smooth nodal margins were lost in 58%, 23%, and 9% of metastatic nodes, lymphomas, and benign nodes, respectively. Heterogeneous nodal parenchyma on T1- or fat-suppressed T2-weighted images, or both, was observed in 88%, 29%, and 23% of metastatic nodes, lymphomas, and benign nodes, respectively. The apparent diffusion coefficients were significantly different among these three node groups (p < 0.001), with metastatic nodes being the highest, followed by benign nodes. Logistic regression analyses showed that heterogeneous nodal parenchyma and apparent diffusion coefficient levels were significant in discriminating metastatic nodes, and apparent diffusion coefficient levels in discriminating lymphomas. Combined use of these MR microscopic criteria on nodal architecture and apparent diffusion coefficients yielded 90% accuracy (86% sensitivity, 94% specificity) and 93% accuracy (85% sensitivity, 95% specificity) for discriminating metastatic nodes and lymphomas, respectively. CONCLUSION: The nodal architecture and apparent diffusion coefficient levels on MR microimaging may provide useful information in diagnosing benign and malignant nodes in the neck.

Adult↗

Assessment of coronary arteries with total study time of less than 30 minutes by using whole-heart coronary MR angiography.

This study had institutional review board approval, and all patients gave informed consent. The purpose of this study was to prospectively evaluate the use of whole-heart three-dimensional (3D) coronary magnetic resonance (MR) angiography in patients suspected of having coronary artery disease. Whole-heart coronary MR angiography was performed in 39 patients (30 men and nine women; mean age, 63.9 years +/- 15.6 [standard deviation]) by using a steady-state free precession sequence with free breathing. Twenty patients (16 men and four women; mean age, 64.9 years +/- 11.7) also underwent conventional coronary angiography. MR angiography was successfully completed in 34 of 39 patients (87%); the average imaging time was 13.8 minutes +/- 3.8. Sensitivity and specificity of MR angiography for detecting significant stenosis were 82% (14 of 17 arteries) and 91% (39 of 43 arteries), respectively. Whole-heart coronary MR angiography with a navigator-gated steady-state sequence can enable reliable 3D visualization of the coronary arteries in patients suspected of having coronary artery disease.

Coronary Angiography↗

Oxygen-enhanced MR imaging: correlation with postsurgical lung function in patients with lung cancer.

PURPOSE: To prospectively determine if lung function as assessed with oxygen-enhanced magnetic resonance (MR) imaging correlates with postsurgical lung function in patients with lung cancer, as compared with quantitative and qualitative findings of computed tomography (CT) and scintigraphy. MATERIALS AND METHODS: Study received institutional review board approval, and informed patient consent was obtained. Thirty consecutive patients (16 men and 14 women, aged 44-81 years; mean age, 65 years) considered candidates for lung resection underwent oxygen-enhanced MR imaging, CT, perfusion scintigraphy, and measurement of forced expiratory volume in 1 second (FEV1). A respiratory-synchronized inversion-recovery half-Fourier single-shot turbo spin-echo MR sequence was used for data acquisition. Correlation of postsurgical lung function (postsurgical FEV1) as determined with oxygen-enhanced MR imaging (FEV1MR), quantitative assessment with CT (FEV1Quant), qualitative assessment with CT (FEV1Qual), and perfusion scintigraphy (FEV1PS) was conducted with actual postsurgical FEV1, and the limits of agreement of each were determined with Bland-Altman analysis. RESULTS: Correlation between postsurgical FEV1MR and actual postsurgical FEV1 values was excellent (r2= 0.81, P < .001); it was better than that of FEV1Qual (r2= 0.76) and FEV1PS (r2= 0.77) and similar to that of FEV1Quant (r2= 0.81) values. The limits of agreement of FEV1MR were between -9.9% and 10.9%. CONCLUSION: Oxygen-enhanced MR imaging can be used to predict posturgical lung function in patients with lung cancer, similar to quantitative CT.

Adult↗

Fast and high-resolution MR sialography using a small surface coil.

PURPOSE: To establish a fast and high-resolution MR sialographic technique that provides fast and high-resolution imaging. MATERIALS AND METHODS: MR sialography was performed on a 1.5-T MR imager using a small (47-mm) surface coil. We determined appropriate sequence parameters, and then applied the technique to the salivary glands of 143 patients with xerostomia (including those with Sjögren's syndrome or hyperlipidemia) or salivary gland inflammation. We compared the high-resolution MR sialography with conventional x-ray sialography in the patients with xerostomia to evaluate the effectiveness of the MR sialography technique. RESULTS: We found that a single-shot, single-slice MR sialography (TR/TR/number of signal acquisitions [NSA] = 8000 msec/1000 msec/6) using a small surface coil provides excellent duct images that are clinically feasible with fast (imaging time of 56 seconds) and high-resolution images. An alternative three-dimensional MR sialography technique provided better details of the branches at the expense of imaging time. The MR sialography technique using a small surface coil depicted effectively the ductal changes in the salivary glands in patients with or without Sjögren's syndrome, reflecting the severity of the diseases. CONCLUSION: We conclude that MR sialography can be performed using a fast and high-resolution sequence.

Adult↗

Implications of SENSE MR in routine clinical practice.

Sensitivity encoding (SENSE) uses multiple MRI receive coil elements to encode spatial information in addition to traditional gradient encoding. Requiring less gradient encodings translates into shorter scan times, which is extremely beneficial in many clinical applications. SENSE is available to routine diagnostic imaging for the past 2 years. This paper highlights the use of SENSE with scan time reduction factors up to 6 in contrast-enhanced MRA, routine abdominal imaging, mammography, cardiac and neuro imaging. It is shown that SENSE has opened new horizons in both routine and advanced MR imaging.

Contrast Media↗

High-resolution selective three-dimensional magnetic resonance coronary angiography with navigator-echo technique: segment-by-segment evaluation of coronary artery stenosis.

PURPOSE: To investigate the feasibility of high-resolution selective three-dimensional (3D) magnetic resonance coronary angiography (MRCA) in the evaluation of coronary artery stenoses. MATERIALS AND METHODS: In 12 patients with coronary artery stenoses, MRCA of the coronary artery groups, including the coronary segments with stenoses of 50% or greater based on conventional x-ray coronary angiography (CAG), was performed with double-oblique imaging planes by orienting the 3D slab along the major axis of each right coronary artery-left circumflex artery (RCA-LCX) group and each left main trunk-left anterior descending artery (LMT-LAD) group. Ten RCA-LCX and five LMT-LAD MR angiograms were obtained, and the results were compared with those of conventional x-ray angiography. RESULTS: Among 70 coronary artery segments expected to be covered, a total of 49 (70%) segments were fully demonstrated in diagnostic quality. The identification of segmental location of stenoses showed as high an accuracy as 96%. The retrospective analysis for stenosis of 50% or greater yielded the sensitivity, specificity, and accuracy of 80%, 85%, and 84%, respectively. CONCLUSION: Selective 3D MRCA has the potential for segment-by-segment evaluation of major portions of the right and left coronary arteries with high accuracy.

Aged↗

Dynamic oxygen-enhanced MRI reflects diffusing capacity of the lung.

The purpose of this study was to demonstrate the feasibility of dynamic oxygen-enhanced MRI in a clinical setting. We hypothesized that dynamic oxygen enhancement can reflect the regional diffusing capacity of the lung. Ten patients with pulmonary emphysema and seven healthy volunteers were examined with a respiratory-synchronized inversion recovery single-shot turbo spin-echo sequence (TR = 3200-5000 ms, TE = 16 ms, TI = 720 ms, ETS = 4 ms) following 100% oxygen inhalation, using a 1.5 T whole-body scanner. Maximum mean relative enhancement ratios calculated by averaging six defined regions of interest (ROIs) in both lungs were statistically compared between healthy volunteers and patients, and were correlated with diffusing lung capacity (%DL(CO)). In patients with pulmonary emphysema, maximum mean relative enhancement ratios were significantly decreased compared to those in healthy volunteers (P = 0.0008). Maximum mean relative enhancement ratio had excellent correlation with % DL(C0) (r(2) = 0.83). Dynamic oxygen-enhanced MRI may reflect the diffusing capacity of the lung; therefore, imaging of oxygen enhancement with MRI may provide maps of the diffusing capacity.

Adult↗

Effect of intravenous gadolinium-DTPA on diffusion-weighted images: evaluation of normal brain and infarcts.

BACKGROUND AND PURPOSE: Diffusion-weighted imaging (DWI) is usually done before administration of intravenous contrast agents. Repetition of DWI is occasionally necessary after administration, but the effects of contrast material on DWI and apparent diffusion coefficient (ADC) values have not yet been fully examined. The present study assesses whether administration of gadolinium-based contrast material significantly affects DWI and ADC values. METHODS: We examined DWI data from 39 patients (mean age, 67.9 years; range, 34 to 87 years) who were evaluated with a stroke protocol at our institute. All patients were scanned at the acute or subacute stages of infarct from 3 hours to 5 days after symptom onset. We obtained DWI images using single-shot echo-planar imaging with a b value of 1000 s/mm2. Patients were injected with 0.1 mmol gadopentetate dimeglumine per 1 kg body weight. We examined the signal-to-noise ratio of the normal brain and the infarct and evaluated the contrast-to-noise ratio of each lesion. In addition, we compared the ADC values calculated from the DWI images before and after administration of contrast. The statistical significance of differences between precontrast and postcontrast administration was determined by use of a paired t test. RESULTS: The signal-to-noise and contrast-to-noise ratios of the DW images were not significantly different before and after administration of contrast agent. The ADC values were slightly lower after administration of contrast agent for both normal brain (P=0.0011) and infarcts (P=0.038). The estimated differences in the ADC values were approximately 1.3% and 3.5% for normal brain and infarcts, respectively. CONCLUSIONS: The lack of a significant difference between the signal-to-noise and contrast-to-noise ratios of DW images before and after administration of contrast agent indicates the feasibility of postcontrast DWI.

Adult↗

Diffusion weighted whole body imaging with background body signal suppression (DWIBS): technical improvement using free breathing, STIR and high resolution 3D display.

PURPOSE: To examine a new way of body diffusion weighted imaging (DWI) using the short TI inversion recovery-echo planar imaging (STIR-EPI) sequence and free breathing scanning (diffusion weighted whole body imaging with background body signal suppression; DWIBS) to obtain three-dimensional displays. MATERIALS AND METHODS: 1) Apparent contrast-to-noise ratios (AppCNR) between lymph nodes and surrounding fat tissue were compared in three types of DWI with and without breath-holding, with variable lengths of scan time and slice thickness. 2) The STIR-EPI sequence and spin echo-echo planar imaging (SE-EPI) sequence with chemical shift selective (CHESS) pulse were compared in terms of their degree of fat suppression. 3) Eleven patients with neck, chest, and abdominal malignancy were scanned with DWIBS for evaluation of feasibility. Whole body imaging was done in a later stage of the study using the peripheral vascular coil. RESULTS: The AppCNR of 8 mm slice thickness images reconstructed from 4 mm slice thickness source images obtained in a free breathing scan of 430 sec were much better than 9 mm slice thickness breath-hold scans obtained in 25 sec. High resolution multi-planar reformat (MPR) and maximum intensity projection (MIP) images could be made from the data set of 4 mm slice thickness images. Fat suppression was much better in the STIR-EPI sequence than SE-EPI with CHESS pulse. The feasibility of DWIBS was showed in clinical scans of 11 patients. Whole body images were successfully obtained with adequate fat suppression. CONCLUSION: Three-dimensional DWIBS can be obtained with this technique, which may allow us to screen for malignancies in the whole body.

Abdominal Neoplasms↗