PubMed Health⌕ Search

Biomedical subjects

Marcella Giovannini

Publications and source records attributed to Marcella Giovannini.

6 recordsLinked to original sources

Characterization of a near-room-temperature, continuous-wave quantum cascade laser for long-term, unattended monitoring of nitric oxide in the atmosphere.

We report on power, spectral linewidth, and mode purity for a cw 5.3 microm quantum cascade laser operated on a thermo-electric cooler. A totally noncryogenic nitric oxide monitor was constructed by integrating this laser with an astigmatic multipass cell and a thermo-electrically cooled infrared detector. The resulting instrument is capable of continuous unattended monitoring of ambient, atmospheric nitric oxide for several weeks with no operator intervention. The detection method was rapid sweep, direct absorption spectroscopy. A detection sensitivity of 0.03 parts in 10(9) is achieved with 30 s averaging time with a path length of 210 m, corresponding to an absorbance path length product of 1.5 x 10(-10) cm(-1).

Journal Article↗

Fabrication and characterization of molecular beam epitaxy grown thin-film GaAs waveguides for mid-infrared evanescent field chemical sensing.

Thin-film GaAs waveguides were designed and fabricated by molecular beam epitaxy for use in mid-infrared (MIR) evanescent field liquid sensing. Waveguides were designed to facilitate the propagation of a single mode at a wavelength of 10.3 microm emitted from a distributed feedback quantum cascade laser, which overlaps with molecular selective absorption features of acetic anhydride. The characterization of the waveguides shows transmission across a broad MIR band. Evanescent field absorption measurements indicate a significant sensitivity enhancement in contrast to multimode planar silver halide waveguides.

Equipment Design↗

Mid-infrared single-photon counting.

We report a procedure to detect mid-infrared single photons at 4.65 microm by means of a two-stage scheme based on sum-frequency generation, by using a periodically poled lithium niobate nonlinear crystal and a silicon avalanche photodiode. An experimental investigation shows that, in addition to a high timing resolution, this technique yields a detection sensitivity of 1.24 pW with 63 mW of net pump power.

Journal Article↗

Continuous-wave operation of a broadly tunable thermoelectrically cooled external cavity quantum-cascade laser.

Continuous-wave operation of an external cavity quantum-cascade laser on a thermoelectric cooler is reported. The active region of the gain element was based on a bound-to-continuum design emitting near 5.15 microm. The external cavity setup was arranged in a Littrow configuration. The front facet of the gain chip was antireflection coated. The laser could be tuned over more than 170 cm(-1) from 4.94 to 5.4 microm and was single mode over more than 140 cm(-1). The output power was in excess of 10 mW over approximately 100 cm(-1) and in excess of 5 mW over approximately 130 cm(-1) at -30 degrees C.

Journal Article↗

Imaging at 3.4 Thz with a quantum-cascade laser.

We have assembled a single-frequency imaging system at 3.4 THz with a quantum-cascade laser. Images of electronic and biological applications are demonstrated. We operate the laser with a peak output power of 2.5 mW at a 7% duty cycle and a 22 K operating temperature. The minimum spot size is 340 microm. The signal is detected with a single-element deuterated triglycine sulfate detector, and images are captured by scanning of the sample.

Journal Article↗

Terahertz quantum cascade lasers.

Recent developments in terahertz quantum cascade lasers are reviewed. Structures operating from a wavelength of lambda = 66 microm down to lambda = 87 microm are demonstrated. These devices used either a three-quantum-well chirped-superlattice active region or an active region based on a bound-to-continuum transition. The comparison between structures grown in a waveguide based on a single interface plasmon and a buried contact and (non-lasing) structures using a double plasmon waveguide demonstrates the importance of waveguide design on the operation of such devices. Continuous-wave operation up to a maximum temperature of 55 K with up to 15 mW output power at 10 K was demonstrated.

Journal Article↗