PubMed Health⌕ Search

Biomedical subjects

Marcelo E Vazquez

Publications and source records attributed to Marcelo E Vazquez.

4 recordsLinked to original sources

Cytotoxic effects of low- and high-LET radiation on human neuronal progenitor cells: induction of apoptosis and TP53 gene expression.

The induction of apoptosis, TP53 expression, caspase activation and cell toxicity were investigated after exposure of cells of the human neuronal progenitor cell line Ntera2 (NT2) to low-LET radiation (gamma and X rays). The data indicates that irradiation of NT2 cells quickly induced TP53 expression, which was followed in time by an increase in caspase activity, and ultimately resulted in the induction of apoptosis. Induction of apoptosis was dependent on dose, and the highest levels were measured 48 h after exposure. For comparison, the level of apoptosis induced by high-LET particle radiation (1 GeV/ nucleon iron ions) was also determined and was found to be dependent on dose. The relative biological effectiveness (RBE) was estimated from the slopes of the dose-response curves for the induction of apoptosis. The RBE(max) for apoptosis 48 h after exposure was at least 3.4. In short, exposure to high-LET radiation results in a more efficient and greater induction of apoptosis in human neuronal progenitor cells than low-LET radiation.

Apoptosis↗

Effects of heavy ion to the primary [correction of rimary] culture of mouse brain cells.

To investigate effects of low dose heavy particle radiation to CNS system, we adopted mouse neonatal brain cells in culture being exposed to heavy ions by HIMAC at NIRS and NSRL at BNL. The applied dose varied from 0.05 Gy up to 2.0 Gy. The subsequent biological effects were evaluated by an induction of apoptosis and neuron survival focusing on the dependencies of the animal strains, SCID, B6, B6C3F1, C3H, used for brain cell culture, SCID was the most sensitive and C3H the least sensitive to particle radiation as evaluated by 10% apoptotic criterion. The LET dependency was compared with using SCID and B6 cells exposing to different ions (H, C, Ne, Si, Ar, and Fe). Although no detectable LET dependency was observed in the high LET (55-200 keV/micrometers) and low dose (<0.5 Gy) regions. The survivability profiles of the neurons were different in the mouse strains and ions. In this report, a result of memory and learning function to adult mice after whole-body and brain local irradiation at carbon ion and iron ion.

Animals↗

An algorithm for neurite outgrowth reconstruction.

We present a numerical method which provides the ability to analyze digitized microscope images of retinal explants and quantify neurite outgrowth. Few parameters are required as input and limited user interaction is necessary to process an entire experiment of images. This eliminates fatigue related errors and user-related bias common to manual analysis. The method does not rely on stained images and handles images of variable quality. The algorithm is used to determine time and dose dependent, in vitro, neurotoxic effects of 1 GeV per nucleon iron particles in retinal explants. No neurotoxic effects are detected until 72 h after exposure; at 72 h, significant reductions of neurite outgrowth occurred at doses higher than 10 cGy.

Algorithms↗

Effects of low dose particle radiation to mouse neonatal neurons in culture.

To investigate effects of low dose heavy particle radiation to CNS system, we adopted mouse neonatal brain cells in culture being exposed to heavy ions generated by HIMAC at NIRS and BNL. The applied dose varied from 0.05 Gy up to 2.0 Gy. The subsequent biological effects were evaluated by an induction of apoptosis focusing on the dependencies of (1) the animal strains with different radiation sensitivities, and (2) LET with different nuclei. Of the three mouse strains, SCID, B6 and C3H, used for brain cell culture, SCID was the most sensitive and C3H the least sensitive to both X-ray and carbon ion ( 290 MeV/n) as evaluated by 10% apoptotic criterion. However, the sensitivity differences among the strains were much smaller in case of carbon ion comparing to that of X-ray. Regarding the LET dependency, the sensitivity was compared with using C3H and B6 cells between the carbon (13 keV/micrometers) and neon (70 keV/micrometers) ions. Carbon (290 MeV/n) did not give a detectable LET dependency from the criterion whereas the neon (400 MeV/n) showed 1.4 fold difference for both C3H and B6 cells. Although a LET dependency was examined by using the most sensitive SCID cells, no significant difference was detected.

Animals↗