PubMed Health⌕ Search

Biomedical subjects

Marcelo R Risk

Publications and source records attributed to Marcelo R Risk.

5 recordsLinked to original sources

Autonomic function in sleep apnea patients: increased heart rate variability except during REM sleep in obese patients.

The objective of this study was to examine heart rate variability (HRV) among sleep stages in obstructive sleep apnea (OSA) patients. The study was retrospective within subjects and examined the sleep stages and HRV in relation to OSA, age, body mass index (BMI), and sex. Data collected during diagnostic polysomnograms were used in this study. There were 105 clinical patients undergoing polysomnography for suspected OSA. We sampled the electrocardiogram (ECG) from wakefulness, stage 2, and REM sleep and analyzed for frequency domain HRV. Sampled epochs were free of apnea and arousals. Heart rate variability decreased with age. Total frequency variability (TF) and low frequency variability (LF) in wakefulness and REM sleep increased as apnea severity increased. Measures of TF, LF, and the LF/HF ratio were greatest in REM sleep. There was less LF and TF in Stage REM sleep in patients with higher BMI. In conclusion, the decrease in HRV with aging is a robust finding that occurs even in a clinical sleep apnea population. However, apnea does not mimic aging effects on the heart because HRV increased as apnea severity increased. The decrease in HRV during REM sleep in the obese apnea patients suggests the possibility of an autonomic dysfunction in this subgroup.

Adult↗

Quantitative sensory testing cannot differentiate simulated sensory loss from sensory neuropathy.

OBJECTIVE: To differentiate the quantitative sensory testing (QST) results of subjects simulating small and large fiber sensory loss from those of normal subjects and subjects with sensory peripheral neuropathy. BACKGROUND: QST is used to measure sensory thresholds in clinical, epidemiologic, and research studies. It is not known whether there are objective test results that characterize the subject seeking to deceive the examiner. METHODS: The Computer Aided Sensory Examination IV 4, 2, and 1 stepping algorithm was used to determine vibration and cold perception in nine naïve subjects. Subjects were asked to simulate sensory loss (on two occasions) and to respond normally on one occasion. Test results were compared to those of subjects with diabetic sensory neuropathy. Each QST trial was performed three times. RESULTS: Reproducibility, measured by the intraclass correlation coefficient, was similar in all groups for the vibration perception test (simulation 1: 0.68 [95% CI 0.31, 0.91], simulation 2: 0.82 [95% CI 0.54, 0.95], normal response: 0.77 [95% CI 0.47, 0.94], and subjects with peripheral neuropathy: 0.76 [95% CI 0.18, 0.95]) and the cold perception test (simulation 1: 0.53 [95% CI 0.12, 0.85], simulation 2: 0.82 [95% CI 0.55, 0.95], normal subjects: 0.67 [95% CI 0.30, 0.90] and subjects with peripheral neuropathy: 0.88 [95% CI 0.57, 0.97]), all just noticeable difference units. There were no differences between performance characteristics in the two simulation trials. Responses to null stimuli did not differentiate between groups. CONCLUSION: Test performance characteristics do not permit discrimination among subjects simulating sensory loss, subjects with normal responses, and subjects with peripheral neuropathy.

Adult↗

A biphasic model of limb venous compliance: a comparison with linear and exponential models.

Compliance is not linear within the physiological range of pressures, and linear modeling may not describe venous physiology adequately. Forearm and calf venous compliance were assessed in nine subjects. Venous compliance was modeled by using a biphasic model with high- and low-pressure linear phases separated by a breakpoint. This model was compared with a linear model and several exponential models. The biphasic, linear, and two-parameter exponential models best represented the data. The mean coefficient of determination for the biphasic model was greater than for the linear and exponential models in the calf (biphasic 0.94 +/- 0.04, exponential 0.81 +/- 0.16, P = not significant; and linear 0.54 +/- 0.05, P < 0.05) and forearm (biphasic 0.83 +/- 0.17, exponential 0.79 +/- 0.15, P = not significant; and linear 0.51 +/- 0.06, P < 0.05). The breakpoint pressure in the biphasic model was higher in the calf than the forearm, 34.4 +/- 3.9 vs. 29.1 +/- 4.5 mmHg, P < 0.05. A biphasic model can describe limb venous compliance and delineate differences in venous physiology at high and low pressures. The steep low-pressure phase of the compliance curve extends to higher pressures in the calf than in the forearm, thereby enlarging the range of pressures over which hemodynamic regulation by the calf venous circulation occurs.

Adult↗

A new approach to assist postoperative heart failure in an animal model: juxta-aortic counterpulsation.

Aortic counterpulsation is a useful technique frequently used in postcardiotomy heart failure. An acute heart failure model in open chest sheep was chosen to evaluate hemodynamic improvement with a counterpulsation balloon pump in juxta-aortic position. This was achieved with a manufactured Dacron prosthesis and a balloon pump placed between the prosthesis and the aorta. Juxta-aortic balloon pump counterpulsation in acute experimental heart failure resulted in a significant improvement of hemodynamic parameters: increase of cardiac output (from 0.86 +/- 0.04 to 1.29 +/- 0.09 L/min, p < 0.05) and cardiac index (from 0.03 +/- 0.01 to 0.04 +/- 0.01 L/min per kg, p < 0.05), and decrease of systemic vascular resistance (from 89.76 +/- 6.69 to 66.56 +/- 6.02 mm Hg/L per min, p < 0.05). The extent of aortic diastolic pressure change evaluated through the diastolic and systolic areas beneath the aortic pressure curve (DABAC/SABAC) index before cardiac failure induction showed a significant increase compared with unassisted values (from 0.81 +/- 0.10 to 1.12 +/- 0.09, p < 0.05). Assisted values of DABAC/SABAC index after heart failure induction also showed a significant increase compared with unassisted values (from 0.78 +/- 0.21 to 1.17 +/- 0.38, p < 0.05). Treatment of experimental acute heart failure by juxta-aortic balloon pump counterpulsation allows an effective hemodynamic improvement in open chest sheep.

Acute Disease↗

Juxtaaortic counterpulsation: comparison with intraaortic counterpulsation in an animal model of acute heart failure.

This study was designed to compare the effects of juxtaaortic balloon counterpulsation (JABC), performed in ascending aorta and the aortic arch, with those yielded by intraaortic balloon counterpulsation (IABC) in descending aorta, in experimental animals during induced cardiac failure. JABC was achieved with a manufactured Dacron prosthesis and a balloon pump placed between the prosthesis and the wrapped aorta. JABC resulted in a significant increase of cardiac output (from 2.33+/-0.82 to 2.61+/-1.12 L/min, p < 0.05), cardiac index (from 0.071+/-0.025 to 0.080+/-0.033 L/min/kg, p < 0.05) and diastolic pressure augmentation evaluated through diastolic and systolic areas beneath the aortic pressure curve (DABAC/SABAC) index (from 0.94+/-0.21 to 1.10+/-0.33, p < 0.01). End diastolic aortic pressure showed a significant decrease with JABC (from 31.90+/-7.09 to 27.83+/-9.72 mm Hg, p < 0.05). A close association between percentage of DABAC/SABAC increases obtained with IABC and JABC was observed (r2 = 0.67; p < 0.001). Counterpulsation obtained by a juxtaaortic catheter placed in the arch and the ascending wrapped aorta results in an effective hemodynamic improvement comparable with that achieved by an intraaortic catheter in open chest sheep.

Animals↗