PubMed Health⌕ Search

Biomedical subjects

Marco De Carlo

Publications and source records attributed to Marco De Carlo.

15 recordsLinked to original sources

Primary angioplasty for acute myocardial infarction in a patient with a solitary coronary ostium and a "superdominant" right coronary artery.

Coronary artery anomalies (CAAs) are a rare angiographic finding, sometimes associated with acute coronary events. We report on a case of primary angioplasty for inferior acute myocardial infarction (AMI) in a 66-year-old woman with a solitary coronary ostium in the right sinus of Valsalva and a "superdominant" right coronary artery. We also discuss two potential pitfalls of primary angioplasty: correct interpretation of coronary anatomy and approach to challenging lesions.

Aged↗

Simvastatin does not inhibit intimal hyperplasia and restenosis but promotes plaque regression in normocholesterolemic patients undergoing coronary stenting: a randomized study with intravascular ultrasound.

BACKGROUND: Restenosis after coronary stenting is mainly caused by intimal hyperplasia. Both experimental and clinical studies suggest that statins may be able to inhibit intimal hyperplasia and, therefore, in-stent restenosis (ISR), by mechanisms beyond lipid lowering. METHODS: In a 12-month study, we randomized 71 normocholesterolemic patients to 20 mg simvastatin or no treatment, 2 weeks before elective coronary stenting. Patients were evaluated by quantitative coronary angiography and intravascular ultrasound, immediately after the index procedure and at the 12-month catheterization. RESULTS: Binary ISR was present in 15% and in 18% of simvastatin-treated patients and controls, respectively (P = NS). Intimal hyperplasia did not differ significantly between the 2 groups (3.6 +/- 1.8 vs 3.8 +/- 2.3 mm3/mm, 34% +/- 15% vs 35% +/- 23% for simvastatin vs controls, P = NS). However, persistent plaque decreased with simvastatin but increased in controls (-4.0 +/- 4.0 vs +1.6 +/- 3.8 mm3/mm, -14% +/- 10% vs +6% +/- 12%, P < .05). The same behavior was shown by intermediate plaques at nonstented sites (-2.5 +/- 3.0 vs +1.0 +/- 3.0 mm3/mm, -10% +/- 8% vs +9% +/- 9%, P < .05). Major adverse events at 12 months were present in 11% and 24% of simvastatin-treated patients and controls, respectively (P = .20). CONCLUSIONS: In normocholesterolemic patients undergoing coronary stenting, simvastatin does not prevent intimal hyperplasia or ISR, but it promotes atherosclerotic regression both at stented and at nonstented sites.

Coronary Angiography↗

Distal embolization during primary angioplasty: histopathologic features and predictability.

BACKGROUND: Distal embolization during primary percutaneous coronary interventions (PCIs) may affect myocardial reperfusion. We evaluated the prevalence and features of embolization during primary PCI and its relationship with clinical and angiographic variables. METHODS: Forty-six consecutive patients with acute myocardial infarction underwent primary PCI with a filter-based distal protection device. Histopathologic analysis was performed on retrieved embolic fragments, assessing the presence and relative amount of fibrin, necrosis, lipid droplets, collagen, mucopolysaccharides, and leukocytes, as well as the total debris volume. Such variables were related to baseline clinical and angiographic variables. RESULTS: Embolic material was recovered in 41 (89%) of 46 cases, with a mean total debris volume of 1.2 +/- 2.2 mm3. Prevalent histopathologic patterns were organized thrombus (47%), fresh thrombus (29%), and plaque fragments (24%). At multivariate analysis, none of the baseline clinical variables considered significantly predicted the total debris volume. Among angiographic variables, angiographic signs of high thrombus burden (cut-off coronary occlusion pattern or large intracoronary minus image) independently predicted the total debris volume at multivariate analysis (odds ratio 15.8, P < .005). Compared with its nonuse, abciximab did not affect the total number and the mean total volume of embolized material (15 +/- 16 vs 10 +/- 8 fragments, 1.5 +/- 2.5 vs 1.0 +/- 1.9 mm3, respectively, for both P > .20), or its qualitative composition. CONCLUSIONS: Distal embolization occurs in most patients during primary PCI and mainly consists of plaque fragments and partially organized thrombi, which are likely to be scarcely responsive to antiplatelet drugs. Baseline angiographic signs of a high thrombus burden are the only significant predictors of the extent of distal embolization.

Angioplasty↗

Left ventricular remodeling after primary coronary angioplasty in patients treated with abciximab or intracoronary adenosine.

BACKGROUND: Primary angioplasty is the best treatment of acute myocardial infarction but fails to achieve adequate myocardial reperfusion in 25% to 30% of patients, despite TIMI grade 3 flow. Drug treatment aimed at reducing the no-reflow phenomenon may improve myocardial salvage, thus preventing left ventricular remodeling. Our aim was to evaluate the impact of abciximab and adenosine on immediate angiographic results and on 6-month left ventricular remodeling. METHODS: Ninety consecutive patients undergoing primary angioplasty with coronary stenting were randomized in a sequential alternating fashion to standard abciximab treatment (ABCX) group, intracoronary adenosine distal to the occlusion (ADO) group, or neither (CTRL) group. All patients underwent a clinical and echocardiographic follow-up at 1 and 6 months. The primary end point was the prevalence of 6-month left ventricular remodeling. RESULTS: Baseline clinical, echocardiographic, and angiographic characteristics were similar. Mean final corrected TIMI frame count was 17 +/- 9, 16 +/- 12, and 23 +/- 11 frames in ABCX, ADO, and CTRL patients, respectively (P = .002). Angiographic no-reflow was observed in 7%, 13%, and 17% of ABCX, ADO, and CTRL patients, respectively (P > .20). At 6 months, left ventricular remodeling occurred in 7%, 30%, and 30% of ABCX, ADO, and CTRL patients, respectively (P = .045), with a percent increase in end-diastolic volume of 5% +/- 13%, 15% +/- 15%, and 12% +/- 18% (P = .04). CONCLUSIONS: During primary angioplasty, abciximab enhances myocardial reperfusion, translating into a reduced incidence of 6-month left ventricular remodeling. In contrast, adenosine administration improves angiographic results but does not prevent left ventricular remodeling.

Abciximab↗

Percutaneous ulnar artery approach for primary coronary angioplasty: safety and feasibility.

Transradial approach in primary and rescue angioplasty may be advantageous with respect to the femoral access due to the lower incidence of vascular complications. Ulnar cannulation has been proposed for elective procedures in patients not suitable for transradial approach. We here report on 13 patients undergoing primary angioplasty performed using the transulnar approach. Ulnar access was finally obtained in 10 patients, sheath insertion time ranged from 2 to 5 min, time from arterial puncture to vessel recanalization ranged from 21 to 36 min. Primary angioplasty was successful in all patients. At 30-day echo color Doppler, all ulnar arteries were patent and with a physiologic pattern of flow. Subcutaneous hemorrhage of the forearm was observed in two patients, whereas hematoma, pseudoaneurysm, thrombus, and arterovenous fistula were not observed. In conclusion, transulnar access may represent an additional option in patients undergoing primary angioplasty when the radial artery access site is not available.

Angioplasty, Balloon, Coronary↗

Safety, feasibility, and six-month outcomes of a systematic strategy of direct coronary stenting by a transradial approach in patients with single-vessel disease.

BACKGROUND: Strategies for percutaneous coronary intervention are continuously evolving, in order to reduce complications and to warrant better immediate and long-term outcomes. We sought to evaluate the safety, feasibility, and long-term outcomes of a systematic strategy of coronary stenting without predilation (direct stenting) via a transradial approach for single-vessel procedures. METHODS: Stenting was performed with Snapper stent and wide inner-lumen, preformed, guiding catheters; 118 minimally-selected patients (59% of all single-vessel procedures performed at our center during the study period) were enrolled: among them 39% presented for acute coronary syndromes, 28% were under glycoprotein IIb/IIIa inhibitor treatment, and 10% had a poor left ventricular function; 130 lesions were treated (1.1 stents/lesion): 53% were type B2/C, 8% longer than 20 mm, and 16% on bifurcations. RESULTS: The transradial approach was successful in 96% of cases; 7% required predilation. The immediate angiographic and clinical success rates were 100 and 98% respectively. No bleeding complications occurred when the transradial approach was successful. At 6 months, the mortality, major adverse events, recurrent ischemia, and target lesion revascularization rates were 0, 14, 15, and 10% respectively. CONCLUSIONS: A systematic strategy of direct stenting via a transradial approach for single-vessel procedures seems safe, feasible, and efficacious both immediately, and at 6 months of follow-up, even when treating complex lesions and/or high-risk patients.

Aged↗

Role of platelet glycoprotein IIb/IIIa inhibitors in rescue percutaneous coronary interventions.

In the setting of acute myocardial infarction, thrombolytic therapy fails to restore an adequate epicardial flow in a large number of patients. Although an increasing number of patients undergoes a percutaneous coronary intervention (PCI) after failed thrombolysis, this treatment has been poorly investigated. This review focuses particularly on the safety and prognostic impact of glycoprotein (GP) IIb/IIIa receptor inhibitors after failed thrombolysis. GPIIb/IIIa inhibitors have been demonstrated to improve the clinical outcome in patients undergoing primary PCI. However, the increased risk of bleeding with the administration of potent antiplatelet drugs after full-dose thrombolytics has limited the widespread use of GPIIb/IIIa inhibitors during rescue PCI. We recently reported that abciximab treatment during rescue PCI has a beneficial effect on the short-term prognosis, without excess bleeding complications. This result can be achieved by using the radial approach, a low-dose weight-adjusted heparin regimen, and by limiting the use of aortic counterpulsation. In conclusion, in case of thrombolysis failure, patients should be referred to tertiary hospitals where rescue PCI can be performed with expertise.

Angioplasty, Balloon, Coronary↗

Mechanical prevention of distal embolization during primary angioplasty: safety, feasibility, and impact on myocardial reperfusion.

BACKGROUND: Effective myocardial reperfusion after primary percutaneous coronary intervention (PCI) may be limited by distal embolization. We tested the safety, feasibility, and efficacy of the FilterWire-Ex (FW), a distal embolic protection device, as an adjunct to primary PCI. METHODS AND RESULTS: Fifty-three consecutive patients undergoing primary PCI with FW protection were compared with a matched control group treated by primary PCI alone. Successful FW positioning was obtained in 47 patients (89%) without complications. Histological analysis of the content of the last 13 filters showed multiple embolic debris in all cases. FW use was associated with lower postinterventional corrected TIMI frame count (22+/-14 versus 31+/-19; P=0.005) and higher occurrence of grade 3 myocardial blush (66% versus 36%; P=0.006) and early ST-segment elevation resolution (80% versus 54%; P=0.006). At multivariate analysis, FW use was the only independent predictor of early ST-segment elevation resolution and of grade 3 myocardial blush. FW patients showed lower peak creatine kinase-MB release (236+/-172 versus 333+/-219 ng/mL; P=0.013) and greater improvement at 30 days in left ventricular wall motion score index (-0.30+/-0.19 versus -0.18+/-0.26; P=0.008) and ejection fraction (+7+/-4% versus +4+/-7%; P=0.012). CONCLUSIONS: FW use during primary PCI is feasible and safe. Distal embolization prevention appears to exert a beneficial effect on markers of myocardial reperfusion and on left ventricular function improvement at 30 days.

Angioplasty, Balloon, Coronary↗

Serial Doppler echocardiographic evaluation of small-sized sorin bicarbon prostheses.

OBJECTIVE: The Sorin Bicarbon prosthesis (Sorin Biomedica, Saluggia, Italy) is a bileaflet valve with curved-profile leaflets, a rolling hinge mechanism, and a pyrolytic carbon-coated titanium alloy housing and sewing ring. Although the Sorin Bicarbon prosthesis has been implanted in greater than 80,000 patients, and reference values on the hemodynamic performance of valve prostheses are needed to avoid patient-prosthesis mismatch, few Doppler echocardiographic data are available on the prosthesis in the aortic position. The aim of this study is to provide a detailed echocardiographic evaluation of the hemodynamic performance and regression of left ventricular hypertrophy after aortic valve replacement with the Sorin Bicarbon prosthesis. METHODS: The study included 182 patients who received a 21-mm (n = 61) or 23-mm (n = 121) Sorin Bicarbon prosthesis for pure or prevalent aortic stenosis who underwent serial echocardiograms at 3, 6, and 12 months after aortic valve replacement. RESULTS: Mean and peak gradients significantly decreased (P <.001) during follow-up to values of 12 +/- 3 and 22 +/- 6 mm Hg for the 21-mm prosthesis and values of 11 +/- 4 and 19 +/- 6 mm Hg for the 23-mm prosthesis at 1 year. Left ventricular mass index showed a 17% decrease to 120 +/- 27 g/m(2) in recipients of the 21-mm prosthesis (P <.001) and a 21% decrease to 123 +/- 29 g/m(2) in recipients of the 23-mm prosthesis (P <.001). A larger prosthesis size was the only predictor of a higher left ventricular mass index regression. Among recipients of the 21-mm prosthesis, body surface area of greater than 1.85 m(2) was associated with a lower regression of left ventricular mass index. The effective orifice area index was 1.00 +/- 0.11 and 1.08 +/- 0.14 cm(2)/m(2) in recipients of the 21-mm and 23-mm prostheses, respectively. CONCLUSIONS: Size 21 mm and 23 mm Sorin Bicarbon prostheses show low transprosthetic gradients, with significant reduction of left ventricular mass index during the first postoperative year. The reported effective orifice areas might be useful for aortic valve replacement in patients with a small aortic annulus to avoid patient-prosthesis mismatch.

Aged↗

Clinical outcome in patients with 19-mm and 21-mm St. Jude aortic prostheses: comparison at long-term follow-up.

BACKGROUND: Small-sized prostheses for aortic valve replacement may result in residual left ventricular outflow tract obstruction. Aim of the study was to verify whether implantation of 19-mm versus 21-mm St. Jude Medical standard prostheses (St. Jude Medical, Inc, St. Paul, MN) influences long-term clinical outcome. METHODS: Two hundred twenty-nine patients who underwent aortic valve replacement with 19 mm (group 1, 53 patients) or 21-mm St. Jude Medical standard prostheses (group 2, 176 patients) were included in the study. Mean follow-up of current survivors was 10+/-4 years. RESULTS: Operative mortality was 7.5% in group 1 and 8.5% in group 2. At discharge, an important patient-prosthesis mismatch (effective orifice area index < or = 0.60 cm2/m2) was present in 18% of group 1 versus 5% in group 2 (p = 0.004). Among patients with body surface area less than 1.70 m2, such mismatch was present in 15% of group 1 versus 2% of group 2 (p = 0.008). At last follow-up New York Heart Association (NYHA) functional class (p < 0.001), left ventricular mass reduction (p = 0.02), mean (p = 0.002) and peak transprosthetic gradients (p < 0.001), and effective orifice area index (p = 0.005) were significantly better in group 2. Freedom from sudden death (92%+/-5% vs 99%+/-1%, p = 0.01), valve-related death (84%+/-6% vs 90%+/-5%, p = 0.02), and cardiac events (56%+/-13% vs 86%+/-4%, p = 0.008), were significantly lower in group 1. Effective orifice area index was an independent predictor of late cardiac events. CONCLUSIONS: Although long-term results after aortic valve replacement with small-sized St. Jude Medical standard prostheses are satisfactory, 19-mm valve recipients show a high prevalence of important patient-prosthesis mismatch with less evident functional improvement and higher rate of cardiac events, suggesting a very cautious use of this prosthesis.

Aged↗

Abciximab improves 6-month clinical outcome after rescue coronary angioplasty.

BACKGROUND: Few data are available concerning the effects on clinical outcome and left ventricular function of abciximab administration in patients undergoing rescue percutaneous transluminal coronary angioplasty (PTCA) after failed thrombolysis for acute myocardial infarction. The aim of the study was to investigate such effects. METHODS: Eighty-nine consecutive patients referred to our laboratory from other hospitals for rescue PTCA within 24 hours from the onset of chest pain were prospectively randomized before the procedure to abciximab treatment (44 patients) or placebo (45 patients). No significant differences in baseline characteristics were observed between the 2 groups. Study end points were the occurrence of major adverse cardiac events (MACE) such as death, reinfarction, congestive heart failure, target lesion revascularization, or recurrent ischemia at 30-day and 6-month follow-up and the occurrence of periprocedural bleeding. RESULTS: Mean time from symptom onset to reperfusion was 8.5 +/-5.4 hours; rescue PTCA was successful in 96% of patients. The incidence of major, moderate, and minor bleeding was similar in the 2 groups. At 30-day follow-up, the echocardiographic left ventricular wall motion score index showed a significantly higher improvement in the abciximab group versus the placebo group (P <.001). At 6-month follow-up, the incidence of MACE was 11% in the abciximab group versus 38% in the placebo group (P =.004). Abciximab administration (P =.003) and cardiogenic shock (P =.005) were the only independent predictors of the occurrence of MACE at multivariable analysis. CONCLUSION: Treatment with abciximab during rescue PTCA positively affects clinical outcome at 6-month follow-up without increasing periprocedural bleeding.

Abciximab↗

Intravascular hemolysis in patients with new-generation prosthetic heart valves: a prospective study.

OBJECTIVE: A prospective clinical study was designed to assess the frequency and severity of intravascular hemolysis in patients with new-generation, normally functioning prosthetic heart valves. METHODS: Hemolysis was evaluated in 172 patients with a mechanical prosthesis (53 CarboMedics and 119 Sorin Bicarbon) and in 106 patients with a bioprosthesis (15 St Jude Medical Toronto, 19 Baxter Perimount, and 72 Medtronic Mosaic) in the aortic position, mitral position, or both. Aortic valve replacement was performed in 206 patients, mitral valve replacement in 59 patients, and double valve replacement in 13 patients. The presence of hemolysis was assessed on the basis of the level of serum lactic dehydrogenase and serum haptoglobin and the presence and amount of reticulocytes and schistocytes in the peripheral blood. Severity of intravascular hemolysis was estimated on the basis of serum lactic dehydrogenase. Clinical, echocardiographic, and hematologic evaluations were performed 1, 6, and 12 months after discharge. RESULTS: None of the 278 patients experienced decompensated anemia, whereas at 12 months, mild subclinical hemolysis was identified in 49 patients, 44 (26%) with a mechanical prosthesis and 5 (5%) with a bioprosthesis (P <.001). At multivariate analysis, independent predictors of the presence of subclinical hemolysis were mitral valve replacement (P <.001), use of a mechanical prosthesis (P =.002), and double valve replacement (P =.02). Frequency of hemolysis in patients with stented aortic bioprostheses was 3%, whereas it was absent in those with stentless valves. Among mechanical valve recipients, double versus single valve replacement (P =.04) and mitral versus aortic valve replacement (P =.05) were correlated with the presence of hemolysis; double valve recipients also showed a more severe degree of hemolysis (P =.03). In patients with a Sorin Bicarbon prosthesis, hemolysis was less frequent (22% vs 34%, P =.09) and severe (P <.001) than in those with a CarboMedics prosthesis. CONCLUSIONS: In normally functioning prosthetic heart valves, subclinical hemolysis is a frequent finding. A low incidence of hemolysis is found in stented biologic prostheses, and it is absent in stentless aortic valves. Modifications of valve design may contribute to minimize the occurrence of hemolysis in mechanical prostheses.

Adult↗

P-wave signal-averaged electrocardiogram predicts atrial fibrillation after coronary artery bypass grafting.

BACKGROUND: AF is one of the most common complications after CABG. The aim of the study was to identify the risk factors for postoperative AF. METHODS: Between June and December 2000, 129 consecutive patients (72 men, 47 women; mean age 67 +/- 6 years) underwent preoperative signal-averaged electrocardiogram (SAECG) with assessment of filtered P-wave duration (fPWD) and of the root mean square voltage of the last 10 and 20 ms of atrial depolarization (RMSV10 and RMSV20, respectively) before CABG. RESULTS: Fifty-six (43%) patients developed one episode of AF lasting > 30 seconds at a mean distance of 2.6 +/- 1.8 days after surgery (group A), while 73 patients remained in sinus rhythm (group B). No differences between the two groups were found in terms of age, sex, P-wave duration on the standard ECG, left atrial dimensions, and operative characteristics. In contrast, group A patients showed a significantly longer fPWD (138 +/- 10 vs 111 +/- 9 ms; P < 0.001) and smaller RMSV10 and RMSV20 (2.8 +/- 1.0 vs 4.3 +/- 1.1 microV, P < 0.001; 4.2 +/- 2.1 vs 6.2 +/- 2.0 microV, P < 0.001). Multivariate analysis indicated only fPWD as an independent predictor of AF (P = 0.009). With a cut-off value of 135 ms for fPWD, the occurrence of AF could be predicted with a sensitivity of 84%, a specificity of 73%, a negative predictive value of 85%, and a positive predictive value of 70%. CONCLUSION: Preoperative SAECG is a simple exam that correctly identifies patients at higher risk of AF after CABG. A more widespread use of this technique can be suggested.

Aged↗