PubMed Health⌕ Search

Biomedical subjects

Marco Pelizzone

Publications and source records attributed to Marco Pelizzone.

11 recordsLinked to original sources

Acoustic to electric pitch comparisons in cochlear implant subjects with residual hearing.

The aim of this study was to assess the frequency-position function resulting from electric stimulation of electrodes in cochlear implant subjects with significant residual hearing in their nonimplanted ear. Six cochlear implant users compared the pitch of the auditory sensation produced by stimulation of an intracochlear electrode to the pitch of acoustic pure tones presented to their contralateral nonimplanted ear. Subjects were implanted with different Clarion electrode arrays, designed to lie close to the inner wall of the cochlea. High-resolution radiographs were used to determine the electrode positions in the cochlea. Four out of six subjects presented electrode insertions deeper than 450 degrees . We used a two-interval (one acoustic, one electric), two-alternative forced choice protocol (2I-2AFC), asking the subject to indicate which stimulus sounded the highest in pitch. Pure tones were used as acoustic stimuli. Electric stimuli consisted of trains of biphasic pulses presented at relatively high rates [higher than 700 pulses per second (pps)]. First, all electric stimuli were balanced in loudness across electrodes. Second, acoustic pure tones, chosen to approximate roughly the pitch sensation produced by each electrode, were balanced in loudness to electric stimuli. When electrode insertion lengths were used to describe electrode positions, the pitch sensations produced by electric stimulation were found to be more than two octaves lower than predicted by Greenwood's frequency-position function. When insertion angles were used to describe electrode positions, the pitch sensations were found about one octave lower than the frequency-position function of a normal ear. The difference found between both descriptions is because of the fact that these electrode arrays were designed to lie close to the modiolus. As a consequence, the site of excitation produced at the level of the organ of Corti corresponds to a longer length than the electrode insertion length, which is used in Greenwood's function. Although exact measurements of the round window position as well as the length of the cochlea could explain the remaining one octave difference found when insertion angles were used, physiological phenomena (e.g., stimulation of the spiral ganglion cells) could also create this difference. From these data, analysis filters could be determined in sound coding strategies to match the pitch percepts elicited by electrode stimulation. This step might be of main importance for music perception and for the fitting of bilateral cochlear implants.

Acoustic Stimulation↗

Processes involved in oculomotor adaptation to eccentric reading.

PURPOSE: Adaptation to eccentric viewing in subjects with a central scotoma remains poorly understood. The purpose of this study was to analyze the adaptation stages of oculomotor control to forced eccentric reading in normal subjects. METHODS: Three normal adults (25.7 +/- 3.8 years of age) were trained to read full-page texts using a restricted 10 degrees x 7 degrees viewing window stabilized at 15 degrees eccentricity (lower visual field). Gaze position was recorded throughout the training period (1 hour per day for approximately 6 weeks). RESULTS: In the first sessions, eye movements appeared inappropriate for reading, mainly consisting of reflexive vertical (foveating) saccades. In early adaptation phases, both vertical saccade count and amplitude dramatically decreased. Horizontal saccade frequency increased in the first experimental sessions, then slowly decreased after 7 to 15 sessions. Amplitude of horizontal saccades increased with training. Gradually, accurate line jumps appeared, the proportion of progressive saccades increased, and the proportion of regressive saccades decreased. At the end of the learning process, eye movements mainly consisted of horizontal progressions, line jumps, and a few horizontal regressions. CONCLUSIONS: Two main adaptation phases were distinguished: a "faster" vertical process aimed at suppressing reflexive foveation and a "slower" restructuring of the horizontal eye movement pattern. The vertical phase consisted of a rapid reduction in the number of vertical saccades and a rapid but more progressive adjustment of remaining vertical saccades. The horizontal phase involved the amplitude adjustment of horizontal saccades (mainly progressions) to the text presented and the reduction of regressions required.

Adaptation, Ocular↗

Measurements of electrode position inside the cochlea for different cochlear implant systems.

CONCLUSIONS: This study demonstrates that the exact location of an electrode inside the cochlea needs to be assessed using two complementary measures, namely the length and angle of insertion, both of which are mandatory if one wants to prevent erroneous outcomes. Knowledge of the contact position may become very useful when tuning a cochlear implant processor in a patient with contralateral residual hearing, or in cases of binaural implants. OBJECTIVE: Multichannel cochlear implants restore useful hearing to deaf patients. However, several types of intracochlear electrodes are presently available, each featuring a specific technology or design. The aim of this study was to determine precisely the intracochlear position of the contacts for different electrode arrays. MATERIAL AND METHODS: Electrode array insertions were estimated using special radiographs. A total of 26 cochlear implantations were included in the study: 6 Ineraid; 5 Clarion HiFocus I; 11 Clarion HiFocus II; and 4 Med-El Combi40+. In each case, a measurable reference or marker ring placed close to the round window (within 2 mm) could be identified. Insertion lengths and angles were measured and then plotted on a graphl based on 3D reconstructions. RESULTS: Both Clarion HiFocus I and II electrode arrays were found to be placed close to the inner wall of the cochlea. Ineraid and Med-El Combi40+ electrode arrays were both placed close to the organ of Corti, the Med-El Combi40+ arrays demonstrating the deepest insertions overall. In spite of marked differences in the positions of the contacts, we did not find any correlation with speech perception performance for the different types of implants studied.

Adult↗

Simulation of artificial vision, III: do the spatial or temporal characteristics of stimulus pixelization really matter?

PURPOSE: In preceding studies, simulations of artificial vision were used to determine the basic parameters for visual prostheses to restore useful reading abilities. These simulations were based on a simplified procedure to reduce stimuli information content by preprocessing images with a block-averaging algorithm (square pixelization). In the present study, how such a simplified algorithm affects reading performance was examined. METHODS: Five to six volunteers with normal vision were asked to read full pages of text with a 10 degrees x 7 degrees viewing window stabilized in central vision. In a first experiment, reading performance with off-line and real-time square pixelizations was compared at different resolutions. In a second experiment, off-line square pixelization was compared with off-line Gaussian pixelization with various degrees of overlap. In a third experiment, real-time square pixelization was compared with real-time Gaussian pixelization. RESULTS: Results from the first experiment showed that real-time square pixelization required approximately 30% less information (pixels) than its off-line counterpart. Results from the second experiment, using off-line processing, revealed a restricted range of Gaussian widths for which performances were equivalent or significantly better than that obtained with square pixelization. The third experiment demonstrated, however, that reading performances were similar in both real-time pixelization conditions. CONCLUSIONS: This study reveals that real-time stimulus pixelization favors reading performance. Performance gains were moderate, however, and did not allow for a significant (e.g., twofold) reduction of the minimum resolution (400-500 pixels) needed to achieve useful reading abilities.

Adult↗

FMRI evidence for activation of multiple cortical regions in the primary auditory cortex of deaf subjects users of multichannel cochlear implants.

To investigate the activation of the auditory cortex by fMRI, three deaf subjects users of the Ineraid cochlear implant participated in our study. Possible interference between fMRI acquisition and the implanted electrodes was controlled and safe experimental conditions were obtained. For each subject, electrical stimuli were applied on different intracochlear electrodes, in monopolar mode. Stimulation of each electrode was actually producing auditory sensations of different pitches, as demonstrated by psychophysical pitch-ranking measurements in the same subjects. Because deaf subjects did not hear scanner noise, the data were collected in 'silent background' conditions, i.e. as a result of pure auditory sensations. Functional maps showed activation of the primary auditory cortex, predominantly in the left hemisphere. Stimulation of each different intracochlear electrode revealed different clusters of activation. After cluster grouping, at least three regions have been identified in the auditory cortex of each subject, and comparisons with previous architectonic and functional studies are proposed. However, a tonotopic organization could not be clearly identified within each region. These arguments, obtained without interference with unwanted scanner noise, plead in favor of a functional subdivision of the primary auditory cortex into multiple cortical regions in cochlear implant users.

Adult↗

Simulation of artificial vision: II. Eccentric reading of full-page text and the learning of this task.

Reading of isolated words in conditions mimicking artificial vision has been found to be a difficult but feasible task. In particular at relatively high eccentricities, a significant adaptation process was required to reach optimal performances [Vision Res. 43 (2003) 269]. The present study addressed the task of full-page reading, including page navigation under control of subject's own eye movements. Conditions of artificial vision mimicking a retinal implant were simulated by projecting stimuli with reduced information content (lines of pixelised text) onto a restricted and eccentric area of the retina. Three subjects, naïve to the task, were trained for almost two months (about 1 h/day) to read full-page texts. Subjects had to use their own eye movements to displace a 10 degrees x 7 degrees viewing window, stabilised at 15 degrees eccentricity in their lower visual field. Initial reading scores were very low for two subjects (about 13% correctly read words), and astonishingly high for the third subject (86% correctly read words). However, all of them significantly improved their performance with time, reaching close to perfect reading scores (ranging from 86% to 98% correct) at the end of the training process. Reading rates were as low as 1-5 words/min at the beginning of the experiment and increased significantly with time to 14-28 words/min. Qualitative text understanding was also estimated. We observed that reading scores of at least 85% correct were necessary to achieve 'good' text understanding. Gaze position recordings, made during the experimental sessions, demonstrated that the control of eye movements, especially the suppression of reflexive vertical saccades, constituted an important part of the overall adaptive learning process. Taken together, these results suggest that retinal implants might restore full-page text reading abilities to blind patients. About 600 stimulation contacts, distributed on an implant surface of 3 x 2 mm2, appear to be a minimum to allow for useful reading performance. A significant learning process will however be required to reach optimal performance with such devices, especially if they have to be placed outside the foveal area.

Adult↗

Simulation of artificial vision: I. Eccentric reading of isolated words, and perceptual learning.

Simulations of artificial vision were performed to assess "minimum requirements for useful artificial vision". Retinal prostheses will be implanted at a fixed (and probably eccentric) location of the retina. To mimic this condition on normal observers, we projected stimuli of various sizes and content on a defined stabilised area of the visual field. In experiment 1, we asked subjects to read isolated 4-letter words presented at various degrees of pixelisation and at various eccentricities. Reading performance dropped abruptly when the number of pixels was reduced below a certain threshold. For central reading, a viewing area containing about 300 pixels was necessary for close to perfect reading (>90% correctly read words). At eccentricities beyond 10 degrees, close to perfect reading was never achieved even if more than 300 pixels were used. A control experiment using isolated letter recognition in the same conditions suggested that lower reading performance at high eccentricity was in part due to the "crowding effect". In experiment 2, we investigated whether the task of eccentric reading under such specific conditions could be improved by training. Two subjects, naive to this task, were trained to read pixelised 4-letter words presented at 15 degrees eccentricity. Reading performance of both subjects increased impressively throughout the experiment. Low initial reading scores (range 6%-23% correct) improved impressively (range 64%-85% correct) after about one month of training (about 1 h/day). Control tests demonstrated that the learning process consisted essentially in an adaptation to use an eccentric area of the retina for reading. These results indicate that functional retinal implants consisting of more than 300 stimulation contacts will be needed. They might successfully restore some reading abilities in blind patients, even if they have to be placed outside the foveal area. Reaching optimal performance may, however, require a significant adaptation process.

Adult↗

Electrical field interactions in different cochlear implant systems.

The goal of this study was to evaluate electrical field interactions produced by the stimulation of different types of intracochlear electrodes in 12 adult subjects (three Ineraid, four Clarion S-Series, three S-Series with the electrode positioning system-EPS and two Clarion HiFocus-I with the EPS). Psychophysical measurements were conducted with biphasic stimuli (813 pulse per second, 153.8 micros/phase). "Perturbation" signals (300 ms) were applied to one electrode chosen at the middle of the array and their effects on detection thresholds of "probe" signals (30 ms) were measured on the neighbor basal electrode. Perturbation levels were set below the detection threshold of the perturbation electrode (-2 dB re threshold). Measurements were first conducted for simultaneous stimulation of the probe and of the perturbation electrodes, for monopolar for all subjects and for bipolar stimulus configurations for both Clarion HiFocus-I subjects. The tested Clarion electrodes did not present lower monopolar interactions than the Ineraid electrodes. Nevertheless, considering the shorter distance between electrodes for the Clarion than for the Ineraid, the tested Clarion electrodes might be more selective than the Ineraid. We did not find any significant monopolar electrical field-interaction differences between subjects who received the S-Series array with and without the EPS. We did not find lower interactions for both subjects who received the HiFocus-I array than for subjects who received the S-Series. Electrical field interactions were lower for bipolar than for monopolar configurations for both HiFocus-I subjects. A second set of measurements was conducted for nonsimultaneous stimulation similar to the one used in continuous interleaved sampling sound strategy. These measurements showed that interactions evaluated for simultaneous biphasic stimuli were larger than for nonsimultaneous stimulation.

Adult↗

Forward masking in different cochlear implant systems.

The goal of this study was to evaluate, from a psychophysical standpoint, the neural spread of excitation produced by the stimulation of different types of intracochlear electrode arrays: the Ineraid, the Clarion S-Series on its own or with the Electrode Positioning System (EPS), and the Clarion HiFocus-I with the EPS. The EPS is an independent silicone part designed to bring the electrode array close to the modiolus. Forward masking was evaluated in 12 adult subjects (3 Ineraid, 4 Clarion S-Series, 3 Clarion S-Series+EPS, 3 HiFocus-I+EPS) by psychophysical experiments conducted using trains of biphasic stimuli (813 pulses per second, 307.6 micros/phase). Masker signals (+8 dB re: threshold, 300 ms) were applied to the most apical electrode. Probe signals (30 ms, 10-ms postmasker) were delivered to more basal electrodes. Masked and unmasked detection thresholds of probe signals were measured. For both Clarion HiFocus-I subjects, measurements were conducted in both monopolar and bipolar stimulus configurations. No major differences were found in forward masking between the different intracochlear electrode arrays tested in the monopolar configuration at suprathreshold levels equivalent to those used in speech-coding strategies, but significant differences were found between subjects. A significant negative correlation also was found between the level of forward masking and the consonant identification performance. These measurements showed that the neural spread of excitation was more restricted in the bipolar configuration than in the monopolar configuration for HiFocus-I subjects. It was found that CIS strategies implemented without using apical electrodes, which showed high levels of masking, could improve consonant identification.

Adult↗

Functional MRI of auditory cortex activated by multisite electrical stimulation of the cochlea.

Electrical stimulation of the ear of deaf patients via cochlear implants offers a unique occasion to study activity of central auditory pathways with fMRI, without bias due to scanner noise. Such measurements, however, require one to control the possible interference between fMRI acquisition and the implanted electrodes. A series of measurements on a customized phantom designed to characterize the level of induced currents during MRI acquisition is presented. These experiments demonstrate that the major artifactual contribution is due to radiofrequency interaction and that safe experimental conditions can be obtained with proper shielding of the stimulation cables. The induced currents could be reduced to low levels (<50 microA for a duration <2 ms), below the acoustic perceptual threshold of cochlear implant subjects. Subsequent fMRI experiments on a patient using an Ineraid cochlear implant were conducted. Results revealed bilateral localized activation of the primary auditory cortex. Stimulation of two different intracochlear electrodes elicited activity in two neighboring, but different, regions, in agreement with the known tonotopical organization of the auditory cortex. This work paves the way for fMRI studies of a broad selection of auditory paradigms without interference from unwanted noise.

Artifacts↗

Matching the neural adaptation in the rat ventral cochlear nucleus produced by artificial (electric) and acoustic stimulation of the cochlea.

To investigate neural adaptive properties, near-field evoked potentials were recorded from a chronically implanted electrode in the ventral cochlear nucleus in awake Long-Evans rats exposed to acoustic stimuli or receiving intracochlear electric stimulation. Stimuli were 250-ms trains of repetitive acoustic clicks (10, 30 and 50 dB SPL) or biphasic electric pulses (30, 50 and 70 microA) with intratrain pulse rates ranging from 100 to 1000 pulses per second (pps). The amplitude of the first negative (N(1)) to positive (P(1)) component of the average evoked potentials was measured for each consecutive individual pulse in the train. While a progressive exponential decrease in N(1)-P(1) amplitude was observed as a function of the position of the pulse within the train for both types of stimulation, the decrement of electric responses (adaptive pattern) was substantially less prominent than that observed for acoustic stimuli. Based on this difference, the present work was extended by modifying electric stimuli in order to try to restore normal adaptation phenomena. The results suggest the feasibility of mimicking acoustic adaptation by stimulation with exponentially decreasing electric pulse trains, which may be clinically applicable in the auditory implant field.

Acoustic Stimulation↗