PubMed Health⌕ Search

Biomedical subjects

Marco S Cune

Publications and source records attributed to Marco S Cune.

2 recordsLinked to original sources

Masticatory function with mandibular implant-supported overdentures fitted with different attachment types.

Oral Rehabilitation by means of implant-retained mandibular overdentures is known to improve the oral function. The improvement may depend on the degree of retention and stability of the denture and thus on the type of attachment. In this within-patient cross-over clinical trial, we examined the hypothesis that more retention and stability of the overdenture improves the masticatory function. Eighteen patients received two permucosal implants, a new overdenture, and, successively, three different suprastructure modalities: a magnet, a ball, and a bar-clip attachment. We quantified aspects of the oral function by measuring the electromyographic activity of the jaw muscles and the jaw movement during chewing. The muscle activity was significantly lower for the unsupported new mandibular denture compared with values for the supported new denture. No significant differences in muscle activity were observed among the three attachment types. Furthermore, we did not observe significant differences in jaw muscle activity between the old unsupported denture and the new supported denture, despite significant differences in masticatory performance. Measuring muscle activity during chewing will thus not provide adequate information about masticatory function. Thus, subjects chewed more efficiently after implant treatment. No changes in cycle duration or in jaw movement parameters were observed among the various measurement moments.

Adult↗

A prospective evaluation of Frialoc implants with ball-abutments in the edentulous mandible: 1-year results.

Several surgical and prosthetic concepts for the treatment of patients with mandibular atrophy and related lower denture problems are proposed and described in the literature. The present study discusses and evaluates the use of a new single-stage implant and overdenture with ball-attachment for this purpose. This study evaluates the clinical performance of the implants and abutments and addresses surgical and prosthetic complications that were encountered. Eighteen fully edentulous patients received two, single-stage Frialoc implants (Friadent, Mannheim, Germany). The implants were left to osseointegrate for 3 months and were subsequently provided with ball-abutments and loaded through a mandibular overdenture. After 1-year of clinical service, two implants were lost, which accumulated to a 1-year survival rate of 93.9% (SE 4.2%). Patient satisfaction was high, and prosthetic complications and postinsertion maintenance were minimal. Three abutments loosened, one of which subsequently broke after 5 months of loading. Retightening of the attachment (gold matrix) was performed on seven occasions in four patients. Soft tissue response was excellent. Although minor hypertrophy of the peri-implant mucosa was observed, hardly any marginal bone loss between baseline and 1-year observations occurred. Short-term results indicate that mandibular implant overdenture treatment by means of two ball-abutments, using Frialoc implants and prosthetic components, leads to good clinical results, both from an objective and a subjective perspective.

Aged↗