PubMed Health⌕ Search

Biomedical subjects

Marcus T Alley

Publications and source records attributed to Marcus T Alley.

6 recordsLinked to original sources

Time-resolved 3D quantitative flow MRI of the major intracranial vessels: initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imaging.

Exact knowledge of blood flow characteristics in the major cerebral vessels is of great relevance for diagnosing cerebrovascular abnormalities. This involves the assessment of hemodynamically critical areas as well as the derivation of biomechanical parameters such as wall shear stress and pressure gradients. A time-resolved, 3D phase-contrast (PC) MRI method using parallel imaging was implemented to measure blood flow in three dimensions at multiple instances over the cardiac cycle. The 4D velocity data obtained from 14 healthy volunteers were used to investigate dynamic blood flow with the use of multiplanar reformatting, 3D streamlines, and 4D particle tracing. In addition, the effects of magnetic field strength, parallel imaging, and temporal resolution on the data were investigated in a comparative evaluation at 1.5T and 3T using three different parallel imaging reduction factors and three different temporal resolutions in eight of the 14 subjects. Studies were consistently performed faster at 3T than at 1.5T because of better parallel imaging performance. A high temporal resolution (65 ms) was required to follow dynamic processes in the intracranial vessels. The 4D flow measurements provided a high degree of vascular conspicuity. Time-resolved streamline analysis provided features that have not been reported previously for the intracranial vasculature.

Adult↗

Quantification of vessel wall motion and cyclic strain using cine phase contrast MRI: in vivo validation in the porcine aorta.

Artery wall motion and strain play important roles in vascular remodeling and may be important in the pathogenesis of vascular disease. In vivo observations of circumferentially nonuniform wall motion in the human aorta suggest that nonuniform strain may contribute to the localization of vascular pathology. A velocity-based method to investigate circumferential strain variations was previously developed and validated in vitro; the current study was undertaken to determine whether accurate displacement and strain fields can be calculated from velocity data acquired in vivo. Wall velocities in the porcine thoracic aorta were quantified with PC-MRI and an implanted coil and were then time-integrated to compute wall displacement trajectories and cyclic strain. Displacement trajectories were consistent with observed aortic wall motion and with the displacements of markers in the aortic wall. The mean difference between velocity-based and marker-based trajectory points was 0.1 mm, relative to an average pixel size of 0.4 mm. Propagation of error analyses based on the precision of the computed displacements were used to demonstrate that 10% strain results in a standard deviation of 3.6%. This study demonstrates that it is feasible to accurately quantify strain from low wall velocities in vivo and that the porcine thoracic aorta does not deform uniformly.

Algorithms↗

Steady-state free precession MR imaging: improved myocardial tag persistence and signal-to-noise ratio for analysis of myocardial motion.

Tagging with balanced steady-state free-precession (SSFP) magnetic resonance (MR) imaging by using a steady-state storage scheme for myocardial motion analysis was evaluated. Signal-to-noise ratio (SNR), blood-tissue contrast, and tag persistence in volunteers and phantoms showed improved performance of SSFP imaging with tagging compared with that of radiofrequency spoiled gradient-echo (SPGR) MR imaging with tagging. Choice of flip angle with SSFP imaging involved a trade-off among SNR, blood-tissue contrast, and tag persistence. Increased SNR and tag persistence can be achieved simultaneously with SSFP imaging compared with SPGR tagging methods. As a result, the proposed technique may be useful for analysis of diastolic ventricular function.

Adult↗

Time-resolved three-dimensional phase-contrast MRI.

PURPOSE: To demonstrate the feasibility of a four-dimensional phase contrast (PC) technique that permits spatial and temporal coverage of an entire three-dimensional volume, to quantitatively validate its accuracy against an established time resolved two-dimensional PC technique to explore advantages of the approach with regard to the four-dimensional nature of the data. MATERIALS AND METHODS: Time-resolved, three-dimensional anatomical images were generated simultaneously with registered three-directional velocity vector fields. Improvements compared to prior methods include retrospectively gated and respiratory compensated image acquisition, interleaved flow encoding with freely selectable velocity encoding (venc) along each spatial direction, and flexible trade-off between temporal resolution and total acquisition time. RESULTS: The implementation was validated against established two-dimensional PC techniques using a well-defined phantom, and successfully applied in volunteer and patient examinations. Human studies were performed after contrast administration in order to compensate for loss of in-flow enhancement in the four-dimensional approach. CONCLUSION: Advantages of the four-dimensional approach include the complete spatial and temporal coverage of the cardiovascular region of interest and the ability to obtain high spatial resolution in all three dimensions with higher signal-to-noise ratio compared to two-dimensional methods at the same resolution. In addition, the four-dimensional nature of the data offers a variety of image processing options, such as magnitude and velocity multi-planar reformation, three-directional vector field plots, and velocity profiles mapped onto selected planes of interest.

Contrast Media↗

Rapid MR imaging of articular cartilage with steady-state free precession and multipoint fat-water separation.

OBJECTIVE: To obtain high-quality high-resolution images of articular cartilage with reduced imaging time, we combined a novel technique of generalized multipoint fat-water separation with three-dimensional (3D) steady-state free precession (SSFP) imaging. SUBJECTS AND METHODS: The cartilage of 10 knees in five healthy volunteers was imaged with 3D SSFP imaging and a multipoint fat-water separation method capable of separating fat and water with short TE increments. Fat-saturated 3D spoiled gradient-echo (SPGR) images were obtained for comparison. RESULTS: High-quality images of the knee with excellent fat-water separation were obtained with 3D SSFP imaging. Total imaging time required was 58% less than that required for 3D SPGR imaging with a comparable cartilage signal-to-noise ratio and spatial resolution. Unlike 3D SPGR images, 3D SSFP images exhibited bright synovial fluid, providing a potential arthrographic effect. CONCLUSION: High-quality high-resolution images of articular cartilage with improved fat-water separation, bright synovial fluid, and markedly reduced acquisition times can be obtained with 3D SSFP imaging combined with a fat-water separation technique.

Adult↗

Time-resolved 3-dimensional velocity mapping in the thoracic aorta: visualization of 3-directional blood flow patterns in healthy volunteers and patients.

OBJECTIVE: An analysis of thoracic aortic blood flow in normal subjects and patients with aortic pathologic findings is presented. Various visualization tools were used to analyze blood flow patterns within a single 3-component velocity volumetric acquisition of the entire thoracic aorta METHODS: Time-resolved, 3-dimensional phase-contrast magnetic resonance imaging (3D CINE PC MRI) was employed to obtain complete spatial and temporal coverage of the entire thoracic aorta combined with spatially registered 3-directional pulsatile blood flow velocities. Three-dimensional visualization tools, including time-resolved velocity vector fields reformatted to arbitrary 2-dimensional cut planes, 3D streamlines, and time-resolved 3D particle traces, were applied in a study with 10 normal volunteers. Results from 4 patient examinations with similar scan prescriptions to those of the volunteer scans are presented to illustrate flow features associated with common pathologic findings in the thoracic aorta. RESULTS: Previously reported blood flow patterns in the thoracic aorta, including right-handed helical outflow, late systolic retrograde flow, and accelerated passage through the aortic valve plane, were visualized in all volunteers. The effects of thoracic aortic disease on spatial and temporal blood flow patterns are illustrated in clinical cases, including ascending aortic aneurysms, aortic regurgitation, and aortic dissection. CONCLUSION: Time-resolved 3D velocity mapping was successfully applied in a study of 10 healthy volunteers and 4 patients with documented aortic pathologic findings and has proven to be a reliable tool for analysis and visualization of normal characteristic as well as pathologic flow features within the entire thoracic aorta.

Adult↗