PubMed Health⌕ Search

Biomedical subjects

Marcus Textor

Publications and source records attributed to Marcus Textor.

31 records · Page 2Linked to original sources

Protein resistance of titanium oxide surfaces modified by biologically inspired mPEG-DOPA.

In the present study, we have utilized X-ray photoelectron spectroscopy (XPS), spectroscopic ellipsometry (ELM), and optical waveguide lightmode spectroscopy (OWLS) to examine the surface adsorption and protein resistance behavior of bio-inspired polymers consisting of poly(ethylene glycol) (PEG) conjugated to peptide mimics of mussel adhesive proteins. Peptides containing up to three residues of 3,4-dihydroxyphenylalanine (DOPA), a key component of mussel adhesive proteins, were conjugated to monomethoxy-terminated PEG polymers. These mPEG-DOPA polymers were found to be highly adhesive to TiO2 surfaces, with quantitative XPS analysis providing useful insight into the binding mechanism. Additionally, the antifouling properties of immobilized PEG were reflected in the excellent resistance of mPEG-DOPA-modified TiO2 surfaces to protein adsorption. Measurements of mPEG-DOPA and human serum adsorption were related in terms of ethylene glycol (EG) surface density and serum mass adsorbed and demonstrated a threshold of approximately 15-20 EG/nm2, above which substantially little protein adsorbs. With respect to surface density of adsorbed PEG and the associated nonfouling behavior of the adlayers, strong parallels exist between the nonfouling properties of the surface-bound mPEG-DOPA polymers and PEG polymers immobilized to surfaces using other approaches. Peptide anchors containing three DOPA residues resulted in PEG surface densities higher than those achieved using several existing PEG immobilization strategies, suggesting that peptide mimics of mussel adhesive proteins may be useful for achieving high densities of protein-resistant polymers on surfaces.

Biomimetic Materials↗

Whole blood coagulation on protein adsorption-resistant PEG and peptide functionalised PEG-coated titanium surfaces.

The aim of this study was to investigate whole blood coagulation on low blood plasma protein adsorbing surfaces. For this purpose, the polycationic graft copolymer poly(L-lysine)-g-poly(ethylene glycol) (PLL-g-PEG), PLL-g-PEG grafted with a cell adhesive peptide containing the amino acid sequence -Arg-Gly-Asp- (RGD), and PLL-g-PEG with a control peptide -Arg-Asp-Gly- (RDG) were adsorbed onto titanium (oxide), forming stable monomolecular adlayers through electrostatic attraction. Free oscillation rheometry and complementary techniques were used to measure the coagulation time (CT) and other interactions of the surfaces with native whole blood, recalcified platelet-rich plasma (PRP), and recalcified citrated platelet-free plasma (PFP). The results show that the uncoated titanium surfaces (reference) activated platelets and quickly triggered the coagulation cascade via the intrinsic pathway, whereas the PLL-g-PEG surfaces displayed a prolonged CT, approximately 2-3 times longer compared to uncoated titanium. We hypothesise that blood coagulates outside the vascular system independent of low protein adsorption to or activation by surfaces, due to the absence of an active down-regulation of procoagulative processes by the vascular endothelium.

Blood Coagulation↗

Synergistic interaction of topographic features in the production of bone-like nodules on Ti surfaces by rat osteoblasts.

The objective of this study was to study the responses of osteoblast-like cells to rough Titanium (Ti)-coated epoxy surfaces of differing topographic complexity. Four topographies were studied: polished (PO), coarse-blasted (CB), acid-etched (AE) and coarse-blasted+acid-etched (SLA). Rat osteoblasts were cultured on these surfaces and their morphology, thickness as well as the number and size of bone-like nodules measured. To determine cell shape and cell thickness, fluorescein-5-thiosemicarbazide was used to stain the cell components including the cell membrane, the stained cells were optically sectioned using epifluorescent microscopy and the optical sections were computationally reconstructed to obtain three-dimensional images in which cell volume and cell thickness could be determined. Similarly optical sections of bone-like nodules labeled with tetracycline were also reconstructed to determine their size. The different surface topographies were found to alter the thickness and morphology of osteoblasts cultured on these surfaces. Osteoblasts produced significantly more and larger nodules on SLA compared to other surfaces. Nevertheless and perhaps surprisingly, given the evidence in various cell populations that cell shape can affect cell differentiation, cell thickness was not directly correlated with an increase in bone-like nodule formation. Data were analyzed by factorial analysis of variance. In this way the primary effect of each surface treatment ( i.e. blasting and acid etching) could be assessed as well as their interaction. Both the acid etching and blasting processes significantly affected the number and size of bone-like nodules cultured on Ti surfaces. Moreover there were significant interaction effects indicating that surface topographic features can act synergistically to enhance bone formation. This result suggests that a useful approach to the optimization of surfaces for bone production could involve systematic investigation of combinations of processes each of which produces distinct surface topographical features.

Animals↗

An inverted microcontact printing method on topographically structured polystyrene chips for arrayed micro-3-D culturing of single cells.

With the goal to investigate the relation of shape and function of single cells or clusters of cells in a 3-dimensional (3-D) microenvironment, we present a novel platform technology to create arrays of microwells on polystyrene (PS) chips for hosting cells in a local microenvironment characterized by controlled shape and surface chemistry. The micro-3-D cell culturing combines 2-dimensional chemical patterning with topographical microstructuring presenting to the cells a local 3-D host structure. Microwells of controlled dimensions were produced by a two-step replication process, based on standard microfabrication of Si, replica molding into poly(dimethylsiloxane), and hot embossing of PS. This allowed the production of large numbers of microstructured surfaces with high reproducibility and fidelity of replication. Using inverted micro contact printing, the plateau surface between the microwells was successfully passivated to block adsorption of proteins and prevent cell attachment by transfer of a graft-copolymer, poly(l-lysine)-g-poly(ethylene glycol). The surface inside the microwells was subsequently modified by spontaneous adsorption of proteins or functionalized PLL-g-PEG/PEG-X (X=biotin or specific, cell-interactive peptide) to elicit specific responses inside the wells. Preliminary cell experiments demonstrated the functionality of such a device to host single epithelial cells (MDCK II) inside the functionalized microwells and thus to control their 3-D shape. This novel platform is useful for fundamental cell-biological studies and applications in the area of cell-based sensing.

Adsorption↗

Immobilization of the enzyme beta-lactamase on biotin-derivatized poly(L-lysine)-g-poly(ethylene glycol)-coated sensor chips: a study on oriented attachment and surface activity by enzyme kinetics and in situ optical sensing.

Understanding the conformation, orientation, and specific activity of proteins bound to surfaces is crucial for the development and optimization of highly specific and sensitive biosensors. In this study, the very efficient enzyme beta-lactamase is used as a model protein. The wild-type form was genetically engineered by site-directed mutagenesis to introduce single cysteine residues on the surface of the enzyme. The cysteine thiol group is subsequently biotinylated with a dithiothreitol (DTT)-cleavable biotinylation reagent. beta-Lactamase is then immobilized site-specifically via the biotin group on neutral avidin-covered surfaces with the aim to control the orientation of the enzyme molecule at the surface and study its effect on enzymatic activity using Nitrocefin as the substrate. The DTT-cleavable spacer allows the release of the specifically bound enzyme from the surface. Immobilization of the enzyme is performed on a monolayer of the polycationic, biotinylated polymer PLL-g-PEG/PEG-biotin assembled on niobium oxide (Nb2O5) surfaces via neutral avidin as the docking site. Two different assembly protocols, the sequential adsorption of avidin and biotinylated beta-lactamase and the immobilization of preformed complexes of beta-lactamase and avidin, are compared in terms of immobilization efficiency. In situ optical waveguide lightmode spectroscopy and colorimetric analysis of enzymatic activity were used to distinguish between specific and unspecific enzyme adsorption, to sense quantitatively the amount of immobilized enzyme, and to determine Michaelis-Menten kinetics. All tested enzyme variants turned out to be active upon immobilization at the polymeric surface. However, the efficiency of immobilized enzymes relative to the soluble enzymes was reduced about sevenfold, mainly because of impaired substrate (Nitrocefin) diffusion or restricted accessibility of the active site. No significant effect of different enzyme orientations could be detected, probably because the enzymes were attached to the surface through long, flexible PEG chain linkers.

Adsorption↗

Bovine serum albumin adsorption onto colloidal Al2O3 particles: a new model based on zeta potential and UV-vis measurements.

We investigated the adsorption of bovine serum albumin (BSA) on colloidal Al2O3 particles in an aqueous environment. Changes in the zeta potential of the Al2O3 particles upon the adsorption of BSA were measured using an electro-acoustic technique. The mass of protein adsorbed was determined by using UV-vis spectroscopy. The change of the isoelectric point of the Al2O3 powder-protein suspension was found to be a function of adsorbed protein mass. It was shown that approximately one monolayer of BSA was needed to fully mask the surface and to compromise the charge of Al2O3. From titration experiments it follows that about 30-36% of the negatively charged groups of the protein form bonds with the protonated and charged Al2O3 surface. On the basis of our observations we introduced a new adsorption model for BSA on Al2O3 particles.

Adsorption↗

Effect of titanium surface topography on macrophage activation and secretion of proinflammatory cytokines and chemokines.

The macrophage has a major role in normal wound healing and the reparative process around implants. Murine macrophage-like cells RAW 264.7 were used to investigate the effect of titanium surfaces on macrophage activation and secretion of proinflammatory cytokines [interleukin (IL)-1 beta, IL-6, and tumor necrosis factor (TNF)-alpha] and chemokines (monocyte chemoattractant protein-1 and macrophage inflammatory protein-1 alpha). Four topographies were used: those produced by mechanically polishing, coarse sand blasting, acid etching, and sandblasting and acid etching (SLA). Macrophages were plated on the four titanium surfaces at a population density of 5 x 10(5) cells/mL/well. Tissue culture plastic and tissue culture plastic plus lipopolysaccharide (LPS) served as negative and positive control, respectively. In addition, all surfaces were tested for their effects on macrophages in the presence of LPS. Supernatants were collected for assays after 6, 24, and 48 h and the numbers of macrophages attached to the surfaces were quantified using the DAPI (4,6-di-amidino-2-phenylindole) assay. Cytokine and chemokine levels were measured with sandwich enzyme-linked immunosorbent assays. Statistical comparison between the surfaces and the controls was determined by using the two-way analysis of variance including interaction effect (two tailed and p < or = 0.05). Unstimulated macrophages increased their secretion of the proinflammatory cytokine (TNF-alpha) when attached to rough surfaces (acid etching and SLA, p < or = 0.05). In macrophages stimulated with LPS, the roughest surface SLA produced higher levels of IL-1 beta, IL-6, and TNF-alpha at 24 and 48 h than all other surfaces (p < or = 0.05). Surface topography also modulated the secretion of the chemokines monocyte chemoattractant protein-1 and macrophage inflammatory protein-1 alpha by macrophages. Unstimulated macrophages attached to the SLA surface down-regulated their production of chemokines (p < or = 0.05) whereas LPS-stimulated macrophages attached to the SLA surface up-regulated their production (p < or = 0.05). Moreover, the SLA surface was found to act synergistically with LPS as well as the combination of blasting and etching features of the SLA surface resulted in significant release of proinflammatory cytokines and chemokines by stimulated macrophages at 24 and 48 h (p < or = 0.05). This in vitro study has demonstrated that surface topography, in particular the SLA surface, modulated expression of proinflammatory cytokines and chemokines by macrophages in a time-dependent manner.

Animals↗

Reduction of friction at oxide interfaces upon polymer adsorption from aqueous solutions.

Reduction of the interfacial friction for the contact of a silicon oxide surface with sodium borosilicate in aqueous solutions has been accomplished through the adsorption of poly(L-lysine)-graft-poly(ethylene glycol) on one or both surfaces. Spontaneous polymer adsorption has been achieved via the electrostatic attraction of the cationic polylysine polymer backbone and a net negative surface charge, present for a specific range of solution pH values. Interfacial friction has been measured in aqueous solution, in the absence of wear, and on a microscopic scale with atomic force microscopy. The successful investigation of the polymer-coated interfaces has been aided by the use of sodium borosilicate microspheres (5.1 microm diameter) as the contacting probe tip. Measurements of interfacial friction as a function of applied load reveal a significant reduction in friction upon the adsorption of the polymer, as well as sensitivity to the coated nature of the interface (single-sided versus two-sided) and the composition of the adsorbed polymer. These measurements demonstrate the fundamental opportunity for lubrication in aqueous environments through the selective adsorption of polymer coatings.

Journal Article↗

Interaction of poly(L-lysine)-g-poly(ethylene glycol) with supported phospholipid bilayers.

Interactions between the graft copolymer poly(L-lysine)-g-poly(ethylene glycol), PLL-g-PEG, and two kinds of surface-supported lipidic systems (supported phospholipid bilayers and supported vesicular layers) were investigated by a combination of microscopic and spectroscopic techniques. It was found that the application of the copolymer to zwitterionic or negatively charged supported bilayers in a buffer of low ionic strength led to their decomposition, with the resulting formation of free copolymer-lipid complexes. The same copolymer had no destructive effect on a supported vesicular layer made up of vesicles of identical composition. A comparison between poly(L-lysine), which did not induce decomposition of supported bilayers, and PLL-g-PEG copolymers with various amounts of PEG side chains per backbone lysine unit, suggested that steric repulsion between the PEG chains that developed upon adsorption of the polymer to the nearly planar surface of a supported phospholipid bilayer (SPB) was one of the factors responsible for the destruction of the SPBs by the copolymer. Other factors included the ionic strength of the buffer used and the quality of the bilayers, pointing toward the important role defects present in the SPBs play in the decomposition process.

Adsorption↗

Microcontact printing of novel co-polymers in combination with proteins for cell-biological applications.

Microcontact printing (microcP) is a cost effective and simple method to create chemically micropatterned surfaces for cell biological applications. We have combined the technique with the spontaneous molecular assembly of a polycationic PEG-grafted copolymer, poly-L-lysine-g-poly(ethylene glycol) (PLL-g-PEG). PLL-g-PEG with omega-functionalized PEG chains was print-transferred onto tissue culture polystyrene (TCPS) or glass substrates, resulting in patterns with a lateral resolution down to 1 microm. Subsequently, dipping in an aqueous solution of non-functionalized PLL-g-PEG was used to backfill the non-printed regions of the surface, rendering them highly protein and thus cell resistant. In a second approach, proteins were stamped and a PLL-g-PEG backfill was applied for passivation of the bare surface regions. Printing of peptide(RGD)-functionalized PLL-g-PEG or proteins combined with a subsequent PLL-g-PEG backfill can be applied to a wide variety of substrate materials with negatively charged surfaces such as TCPS, glass and many metal oxides. We have tested the printed surfaces with human foreskin fibroblasts for cell adhesion and long-term performance and with fish epidermal keratocytes for cell motility and short-time behaviour. Both cell types reacted selectively to the surface micropatterns. Fibroblasts adhered to the printed (adhesive) regions only, where they remained attached up to at least 1 week and were even able to proliferate. Keratocyte spreading and motility were also directed by the geometry of the underlying patterns. The results prove that microcP in conjunction with the use of PLL-g-PEG and its derivatives provides a simple and robust alternative to previously reported micropatterning methods for future cell biological and biotechnological applications.

Animals↗

Ligand-specific targeting of microspheres to phagocytes by surface modification with poly(L-lysine)-grafted poly(ethylene glycol) conjugate.

PURPOSE: The purpose of this study was to demonstrate specific receptor-mediated targeting of phagocytes by functional surface coatings of microparticles, shielding from nonspecific phagocytosis and allowing ligand-specific interactions via molecular recognition. METHODS: Coatings of the comb polymer poly(L-lysine)-g-poly(ethylene glycol) (PLL-g-PEG) were investigated for potential to inhibit 1) nonspecific spreading of human blood-derived macrophages (MOs) and dendritic cells (DCs) on glass and 2) nonspecific phagocytosis of PLL-g-PEG-coated, carboxylated polystyrene (PS) or biodegradable poly(D,L-lactide-co-glycolide) (PLGA) microspheres. Coating was performed by adsorption of positively charged PLL-g-PEG on negatively charged microparticles or plasma-cleaned glass through electrostatic interaction. The feasibility of ligand-specific interactions was tested with a model ligand, RGD, conjugated to PEG chains of PLL-g-PEG to form PLL-g-PEG-RGD and compared with inactive ligand conjugate, PLL-g-PEG-RDG. RESULTS: Coatings with PLL-g-PEG largely impaired the adherence and spreading of MOs and DCs on glass. The repellent character of PLL-g-PEG coatings drastically reduced phagocytosis of coated PS and PLGA microparticles to 10% in presence of serum. With both MOs and DCs, we observed ligand-specific interactions with PLL-g-PEG-RGD coatings on glass and PS and PLGA microspheres. Ligand specificity was abolished when using inactive ligand conjugate PLL-g-PEG-RDG, whereas repellency of coating was maintained. CONCLUSIONS: Coatings of PLL-g-PEG-ligand conjugates provide a novel technology for ligand specific targeting of microspheres to MOs and DCs while reducing nonspecific phagocytosis.

Cells, Cultured↗

Use of Ti-coated replicas to investigate the effects on fibroblast shape of surfaces with varying roughness and constant chemical composition.

A two-stage replica technique with a subsequent titanium (Ti)-coating treatment was used to faithfully replicate topographies of polished, acid-etched, machined-like, finely blasted, coarsely blasted, coarsely blasted and acid-etched, and Ti plasma-sprayed Ti surfaces. The replicas were used to study the influence of different rough surface topographies on the response of human fibroblasts in vitro under conditions of constant surface chemistry for all surfaces. The surface topographies of the replicas were characterized using non-contact laser profilometry, scanning electron microscopy (SEM), and stereo-SEM, whereas surface chemistry was examined using X-ray photoelectron spectroscopy. Fibroblasts were trypsinized and plated onto the Ti-coated epoxy-resin replica surfaces for 24 h and observed with SEM. Fluorescein-5-thiosemicarbazide was used to stain the cell components including cell membrane, and the stained cells were optically sectioned using epifluorescent microscopy. The optical sections were computationally reconstructed to obtain three-dimensional images and cell volume and cell thickness determined. The different surface topographies were found to alter cell thickness and cell morphology. However, cell volume as computed from three-dimensional reconstructions was not affected by surface features. The results suggest that cells distort themselves to accommodate to rough surfaces but their volume is not significantly altered.

Cell Size↗

Effects of surface topography on the connective tissue attachment to subcutaneous implants.

PURPOSE: A major concern for implants that penetrate stratified epithelia is aggressive epithelial proliferation and migration. This epithelial downgrowth on the implant can be inhibited by a firm attachment between the underlying connective tissue and the implant. This study evaluates the connective tissue attachment to titanium implants with various well-defined surface topographies. MATERIALS AND METHODS: Titanium-coated epoxy replicas of polished (PO; R(a) = 0.06 microm), finely blasted (FB; R(a) = 1.36 microm), coarsely blasted (CB; R(a) = 5.09 microm), acid-etched (AE; R(a) = 0.59 microm), coarsely blasted and acid-etched (SLA; R(a) = 4.39 microm), titanium plasma-sprayed (TPS; R(a) = 5.85 microm), machined-like (ML; R(a) = 2.15 microm), and micromachined grooved (GR; V-shaped grooves 30 microm deep) surfaces were implanted subcutaneously in 74 rats for 1 to 11 weeks. Animals were sacrificed weekly. Surfaces were processed for histomorphometric evaluation of connective tissue attachment, capsule thickness, and where applicable, the degree of separation between the tissue and implant. RESULTS: A total of 153 test surfaces were analyzed. Statistical analysis revealed that textured and rough substrata, namely the GR, TPS, AE, CB, and SLA surfaces, exhibited significantly greater (P < .05) connective tissue attachment and thinner fibrous encapsulation when compared to the PO surface. Tissue separation from the implant interface was of significantly lower magnitude and frequency with the rough surfaces than with the PO surface. CONCLUSIONS: The results indicate that rough implant surfaces are associated with stable connective tissue attachment, which has implications for their use in percutaneous and permucosal applications. In addition, data from the AE surface may indicate that the geometry of the surface irregularities can also be a significant determinant of the connective tissue response.

Animals↗