Publications and source records attributed to Marek J Maryanski.

6 recordsLinked to original sources

Heterogeneity phantoms for visualization of 3D dose distributions by MRI-based polymer gel dosimetry.

Heterogeneity corrections in dose calculations are necessary for radiation therapy treatment plans. Dosimetric measurements of the heterogeneity effects are hampered if the detectors are large and their radiological characteristics are not equivalent to water. Gel dosimetry can solve these problems. Furthermore, it provides three-dimensional (3D) dose distributions. We used a cylindrical phantom filled with BANG-3 polymer gel to measure 3D dose distributions in heterogeneous media. The phantom has a cavity, in which water-equivalent or bone-like solid blocks can be inserted. The irradiated phantom was scanned with an magnetic resonance imaging (MRI) scanner. Dose distributions were obtained by calibrating the polymer gel for a relationship between the absorbed dose and the spin-spin relaxation rate of the magnetic resistance (MR) signal. To study dose distributions we had to analyze MR imaging artifacts. This was done in three ways: comparison of a measured dose distribution in a simulated homogeneous phantom with a reference dose distribution, comparison of a sagittally scanned image with a sagittal image reconstructed from axially scanned data, and coregistration of MR and computed-tomography images. We found that the MRI artifacts cause a geometrical distortion of less than 2 mm and less than 10% change in the dose around solid inserts. With these limitations in mind we could make some qualitative measurements. Particularly we observed clear differences between the measured dose distributions around an air-gap and around bone-like material for a 6 MV photon beam. In conclusion, the gel dosimetry has the potential to qualitatively characterize the dose distributions near heterogeneities in 3D.

Algorithms↗

Performance of a commercial optical CT scanner and polymer gel dosimeters for 3-D dose verification.

Performance analysis of a commercial three-dimensional (3-D) dose mapping system based on optical CT scanning of polymer gels is presented. The system consists of BANG 3 polymer gels (MGS Research, Inc., Madison, CT), OCTOPUS laser CT scanner (MGS Research, Inc., Madison, CT), and an in-house developed software for optical CT image reconstruction and 3-D dose distribution comparison between the gel, film measurements and the radiation therapy treatment plans. Various sources of image noise (digitization, electronic, optical, and mechanical) generated by the scanner as well as optical uniformity of the polymer gel are analyzed. The performance of the scanner is further evaluated in terms of the reproducibility of the data acquisition process, the uncertainties at different levels of reconstructed optical density per unit length and the effects of scanning parameters. It is demonstrated that for BANG 3 gel phantoms held in cylindrical plastic containers, the relative dose distribution can be reproduced by the scanner with an overall uncertainty of about 3% within approximately 75% of the radius of the container. In regions located closer to the container wall, however, the scanner generates erroneous optical density values that arise from the reflection and refraction of the laser rays at the interface between the gel and the container. The analysis of the accuracy of the polymer gel dosimeter is exemplified by the comparison of the gel/OCT-derived dose distributions with those from film measurements and a commercial treatment planning system (Cadplan, Varian Corporation, Palo Alto, CA) for a 6 cm x 6 cm single field of 6 MV x rays and a 3-D conformal radiotherapy (3DCRT) plan. The gel measurements agree with the treatment plans and the film measurements within the "3%-or-2 mm" criterion throughout the usable, artifact-free central region of the gel volume. Discrepancies among the three data sets are analyzed.

Equipment Design↗

Dosimetry study of Re-188 liquid balloon for intravascular brachytherapy using polymer gel dosimeters and laser-beam optical CT scanner.

Angioplasty balloons inflated with a solution of the beta-emitter Re-188 have been used for intravascular brachytherapy to prevent restenosis. Coronary stents are in extensive clinical use for the treatment of de novo atherosclerotic stenoses. In this study, the effect of an interposed stent on the dose distribution has been measured for Re-188 balloon sources using the proprietary BANG polymer gel dosimeters and He-Ne laser-beam optical CT scanner. In polymer gels, after ionizing radiation is absorbed, free-radical chain-polymerization of soluble acrylic monomers occurs to form an insoluble polymer. The BANG polymer gel dosimeters used in these measurements allow high resolution, precise, and accurate three-dimensional determination of dosimetry from a given source. Re-188 liquid balloons, with or without an interposed metallic stent, were positioned inside thin walled tubes placed in such a polymer dosimeter to deliver a prescribed dose (e.g., 15 Gy at 0.5 mm). After removing the balloon source, each irradiated sample was mounted in the optical scanner for scanning, utilizing a single compressed He-Ne laser beam and a single photodiode. In the absence of a stent, doses at points along the balloon axis, at radial distance 0.5 mm from the balloon surface and at least 2.5 mm from the balloon ends, are within 90% of the maximum dose. This uniformity of axial dose is independent of the balloon diameter and length. Dose rate and dose uniformity for intravascular brachytherapy with Re-188 balloon are altered by the presence of stent. The dose reduction by the stent is rather constant (13%-15%) at different radial distances. However, dose inhomogeneity caused by the stent decreases rapidly with radial distance.

Brachytherapy↗

Initial evaluation of commercial optical CT-based 3D gel dosimeter.

We evaluated the OCTOPUS-ONE research laser CT scanner developed and manufactured by MGS Research, Inc. (Madison, CT). The scanner is designed for imaging 3D optical density distributions in BANG gels. The scanner operates in a translate-rotate configuration with a single scanning laser beam. The rotating cylindrical gel phantom is immersed in a refractive index matching solution and positioned at the center of a square tank made of plastic and glass. A stationary polarized He-Ne laser beam (633 nm) is reflected from a mirror moving parallel to the tank wall and scans the gel. Another mirror moves synchronously along the opposite side of the tank and collects the transmitted light and sends it to a single stationary silicon photodetector. A filtered backprojection algorithm is used to reconstruct projection data in a plane. The laser-mirrors-detector assembly is mounted on a horizontal platform that moves vertically for slice selection. We have tested the mechanical and optical setup, projection centering on the axis of rotation, linearity, and spatial resolution. We found the optical detector to respond linearly to transmitted light from control samples. The spatial resolution of the scanner was determined by employing a split field resolution technique. We obtained the horizontal and vertical full widths at half maxima of the laser beam intensity profiles as 0.6 and 0.8 mm, respectively. Dose calibration tests of the gel were performed using a nine-field (2 x 2 cm2 each) dose pattern irradiated at different dose levels. Finally, we compared gel-derived 2D planar dose distribution against radiochromic film measured dose distribution for both the nine-field and a uniform 5 x 5 cm2 field of 6 MV x rays. Very similar dose distributions were observed in gel and radiochromic film except in regions of steep dose gradient and highest dose. A dose normalization of 15.6% was required between the two dosimeters due to differences in overall radiation response. After normalization, analysis using the gamma evaluation showed that the radiochromic film and gel-measured dose distributions differed by a maximum gamma of 1.3 using 5% and 1.5 mm dose difference and distance-to-agreement criteria. The optical CT scanner has great potential as a 3D dosimeter, but a few refinements and further testing are necessary before its routine clinical use.

Algorithms↗

Determining optimal gel sensitivity in optical CT scanning of gel dosimeters.

A method for determining the gel sensitivity that is necessary for obtaining optimal image contrast in optical CT scanning of gel dosimeters is presented. The effective dynamic range of the OCTOPUS-ONE research scanner (MGS Research, Inc., Madison, CT) is analyzed. Optical density increments for selected straight-line paths across a gel cylinder to be scanned are calculated based on the optical properties of the polymer gel and the dose distribution from a commercial treatment planning system (Cadplan, Varian Corporation, Palo Alto, CA). Maximum optical density increment across the entire gel is obtained by searching the gel cylinder over a set of transverse planes at different rotational angles. The application of this quantity as a criterion for optimizing the quality of the optical CT scanning is demonstrated through dose verification of two representative treatment plans. When the MU dependence of the dose distribution for a treatment plan is linear, as is the case for static field irradiation, it is possible to scale the treatment plan such that the intensity variation of the signals received by the photodetector spans its entire dynamic range. For treatment plans that are possibly nonlinear, IMRT plans, for example, modification of the sensitivity of the gel material is necessary for the high-dose signals to be collected at a certain signal-to-noise ratio. Results obtained using the optimized CT scanning approach are compared with those from the treatment planning system and the film measurement.

Algorithms↗