PubMed Health⌕ Search

Biomedical subjects

Marek Minarik

Publications and source records attributed to Marek Minarik.

8 recordsLinked to original sources

Parallel optimization and genotyping of multiple single-nucleotide polymorphism markers by sample pooling approach using cycling-gradient CE with multiple injections.

Increasing importance of single-nucleotide polymorphisms (SNPs) in determination of disease susceptibility or in prediction of therapy response brings attention of many molecular diagnostic laboratories to simple and low-cost SNP genotyping methodologies. We have recently introduced a mutation detection technique based on analysis of homo- and heteroduplex PCR fragments resolved in cycling temperature gradient conditions on a conventional multicapillary-array DNA sequencer. The main advantage of this technique is in its simplicity with no requirement for sample cleanup prior to the analysis. In this report we present a practical application of the technology for genotyping of SNP markers in two separate clinical projects resulting in a combined set of 44 markers screened in over 500 patients. Initially, a design of PCR primers and conditions was performed for each SNP marker. Then, optimization of CE running conditions (limited just to the proper selection of temperature cycling) was performed on pools of 20 DNA samples to increase the probability of having each of the two allele types represented in the sample. After selecting the optimum conditions, screening of markers in patients was performed using a multiple-injection approach for further acceleration of the sample throughput. The rate of successful optimization of experimental conditions without any pre-selection based on the SNP sequence or melting characteristics was 80% from the initial SNP marker candidates. By studying the failed markers, we attempt to identify critical factors enabling successful typing. The presented technique is very useful for low to medium sized SNP genotyping projects mostly applied in pharmacogenomic research as well as in clinical diagnostics. The main advantages include low cost, simple setup and validation of SNP markers.

Electrophoresis, Capillary↗

Analysis of genetic events in 17p13 and 9p21 regions supports predominant monoclonal origin of multifocal and recurrent bladder cancer.

Clonality was tested in 86 tumours from 25 patients with recurrent and multifocal superficial bladder transitional cell carcinomas (TCCs) using the analysis of TP53 mutations and of LOH in the 17p13 and 9p21 regions. Tumours from the majority of individuals showed either absence or presence of the same TP53 mutation and/or an identical LOH pattern, with the same allele lost in all tumours. Only two pairs of tumours from two patients had discordant findings, which were incompatible with monoclonality. Therefore, our results rather support the monoclonal model of development of highly recurrent superficial bladder TCCs.

Aged↗

Multicapillary electrophoresis of unlabeled DNA fragments with high-sensitive laser-induced fluorescence detection by counter-current migration of intercalation dye.

Analysis of PCR fragments for applications, such as screening of nucleotide polymorphisms, detection of somatic mutations, or quantification of reverse-transcription PCR products, becomes central in clinical research as well as preventive testing, diagnostic screening, and pharmacogenomic genotyping. A variety of CE techniques, utilizing great potential of multicapillary-array sequencers, is now commonly applied in prevention, diagnosis, and treatment of a wide range of genetic diseases (cancer, cardiovascular, and neurodegenerative diseases, etc.). Costs of fluorescently labeled primers is often a major factor in large-scale projects requiring mutation analysis in hundreds or thousands of samples. In the present paper we introduce a simple approach of detecting unlabeled DNA fragments through intercalation without a need for adding intercalator to the separation polymer matrix. The dye is only added to the anode reservoir, and mixing with the separated DNA fragments takes place upon its migration opposite to the direction of the CE separation. Using two common intercalating dyes (ethidium bromide and SYBR Green II) we present this method as a tool for routine PCR detection and quantification.

Coloring Agents↗

Application of cycling gradient capillary electrophoresis to detection of APC, K-ras, and DCC point mutations in patients with sporadic colorectal tumors.

A previously introduced technique of cycling gradient capillary electrophoresis (CGCE) was applied to monitoring of molecular changes during adenoma-carcinoma transition in progression of sporadic colorectal cancer. The purpose of this work was optimization of separation parameters for selected mutation regions in tumor suppressor genes involved in the early stages of colorectal carcinogenesis, followed by scanning for these mutations in clinical tissue samples from patients with adenomatous polyps and early carcinomas. A total of 47 colorectal tumors in various stages of progression were examined. Main emphasis was given to evaluation of mutation detection sensitivity and specificity required for effective early disease detection. A total of 7 different somatic mutations was identified among 32 K-ras mutant samples, 1 inherited mutation and 5 somatic mutations were identified among 15 adenomatous polyposis coli (APC) mutated samples. None of the two previously reported "deleted in colorectal carcinomas" (DCC) mutations was found in any of the clinical samples. In addition to simple optimization of running conditions, CGCE has demonstrated sensitivity and selectivity allowing detecting small mutant fractions as well as combination of multiple mutants within a single target sequence.

Base Sequence↗

Cycling gradient capillary electrophoresis: a low-cost tool for high-throughput analysis of genetic variations.

In the present work, we introduce a new type of DNA variation detection. This method represents a transfer of melting gel technique onto multicapillary electrophoresis DNA sequencing instrument with further improvements to achieve maximum sample throughput while maintaining a high performance. The main improvement comes from application of cycling (revolving) temporal temperature gradient in place of a single-sweep gradient, commonly used in similar gel-based techniques. This improvement enables utilization of multiple-injection technique, in which multiple samples are injected into the same capillary (or sets of capillaries) separated by predefined time intervals of partial electrophoresis. The periodic oscillation of the temperature results in identical separation conditions of all samples injected in such series. Using this novel approach, we demonstrate a dramatic increase in separation throughput by turning a standard commercial 96-capillary array instrument into a semicontinuous flow mutation detection system capable to screen over 15 000 samples in 24 h of operation on a single 96-capillary commercial instrument. This represents a 10-fold increase in sample throughput over the current comparable technology.

DNA Mutational Analysis↗

Application of high-resolution capillary array electrophoresis with automated fraction collection for GeneCalling trade mark analysis of the yeast genomic DNA.

Capillary array instrument was applied to transcript profiling of the yeast genomic DNA using GeneCalling trade mark chemistry. The instrument integrated a 12-capillary array for DNA separation with a replaceable sieving matrix, laser-induced fluorescence detection and an automated microfraction collector. The DNA fractions, exiting the separation capillaries, were continuously deposited in a 1536-well collection plate made of agarose gel. DNA fragments recovered from selected fractions were cloned and then sequenced. Over 80% of theoretically predicted fragments could be recovered in the collected fractions, cloned and sequenced with an average redundancy of threefold. Excellent correlation of the experimentally obtained sequences with the theoretically predicted gene fragments demonstrated the suitability of capillary array electrophoresis for micropreparative recovery of DNA fragments. This approach, useful especially for rapid DNA expression profiling of unknown genes for nonsequenced organisms, demonstrates the practical capability of the prototype multicapillary fraction collector.

Automation↗

Mutation detection in KRAS Exon 1 by constant denaturant capillary electrophoresis in 96 parallel capillaries.

Mutations in KRAS exon 1 oncogene are frequently found in colon carcinomas. A correlation between the mutated KRAS and the prognosis and outcome of treatment of colon cancer patients was reported in the literature. The object of our work was to establish a high-throughput method with high sensitivity to enable screening of tumor mutation status of KRAS exon 1 in large groups of colon cancer patients. KRAS exon 1 sequences from DNA isolated from 191 sporadic colon cancers were PCR amplified using one primer labeled with fluorescein and a second primer extended by a GC-clamp. After PCR amplification samples were subjected to automated 96-array constant denaturant capillary electrophoresis using a modified MegaBACE 1000 sequencing instrument. Mutant samples were identified by characteristic peak patterns. The sensitivity of detection of a mutant allele in a background of the wild-type alleles was 0.3%. Using the 96-array instrument a typical screening of 191 samples for KRAS mutation status could be performed within 2 h. A KRAS exon 1 mutation was found in 66 of 191 (34.6%) of the samples. The 96-array constant denaturant capillary electrophoresis provides an opportunity for the high-sensitivity screening of large cancer populations for KRAS exon 1 mutations.

Codon↗

Design of a fraction collector for capillary array electrophoresis.

This paper describes a prototype instrument for high-throughput fraction collection with capillary array electrophoresis (CAE). The design of the system was based on a comprehensive collection approach, in which fractions from all capillaries were simultaneously collected in individual collection microwells in predefined time intervals. The location of the fractions in the microwells on the collection plate was determined by monitoring the individual zone velocities close to the end of each capillary. The collection microwell plate was fabricated from buffer-saturated agarose gel, which maintained permanent electrical contact with the separation capillaries during the collection process. Since the collection gel plate consisted of over 90% water, liquid evaporation from the collection wells was minimized. A 12-capillary array instrument was built with two-point detection using a side illumination scheme. The collection performance was demonstrated by reinjection of selected fractions of a double-stranded DNA (dsDNA) separation. The identity of collected DNA fragments was confirmed by PCR and sequencing.

DNA↗