Determination of trace cationic impurities in butylmethylimidazolium-based ionic liquids: from transient to comprehensive single-capillary counterflow isotachophoresis-zone electrophoresis.

Determination of impurities in ionic liquids (ILs) remains a difficult task. In this work, the hyphenation of isotachophoretic (ITP) preconcentration to zone electrophoresis (ZE) has been explored for the trace analysis of the cationic impurities Na(+), Li(+), and methylimidazolium (MI(+)) in butylmethylimidazolium (BMI(+))-based ILs. Simultaneous detection of UV-transparent and UV-absorbing impurities was ensured by a BGE composed of creatinine-acetate buffer. To induce ITP, three different strategies were evaluated: (i) Sample self-stacking ensured by the addition of ammonium acetate (NH(4)Ac) to 25-50-fold diluted IL solution (transient ITP). (ii) Complete ITP-ZE separation performed in a single capillary: ITP was realized in discontinuous electrolytes comprising an 80 mM NH(4)Ac, 40 mM acetic acid, 30 mM alpha-CD, pH 5.05, leading electrolyte (LE) and a 10 mM creatinine, 10 mM acetic acid, pH 4.9, terminating electrolyte (TE). To create the ZE stage, the ITP stack of analytes was moved back toward the capillary inlet by pressure and simultaneously the capillary was filled with the BGE. This protocol made it possible to accommodate a 2.5-times diluted IL sample. (iii) Complete counterflow ITP-ZE with continuous electrokinetic sample supply: the ITP stage was performed in a capillary filled with a 150 mM NH(4)Ac, 75 mM acetic acid, 30 mM alpha-CD, pH 5.0 LE, with 40-times diluted IL at the capillary inlet. BMI(+) from IL acts as the terminating ion. The LODs reached in this latter case were at the 10 and 1 ppb levels for MI(+) and Li(+) in diluted IL matrix, respectively.

Buffers↗

System zones in capillary zone electrophoresis: moving boundaries caused by freely migrating hydroxide ions.

We present theoretical and experimental data indicating that anionic system zones (SZs), due to free migrating hydroxide anions, can be expected in background electrolytes (BGEs) with a low buffer capacity. In the system containing completely unbuffered BGEs the hydroxide ions derived from the sample start to migrate freely through the capillary tube with the mobility of single hydroxide ions and cause stepwise disturbances in the baseline of the detector trace. Remarkably, this type of SZs do not appear to contribute significantly to the electromigration dispersion (EMD) of the zones of the analytes.

Buffers↗

High-performance liquid chromatography determination of phenolic components in wine using off-line isotachophoretic pretreatment.

The off-line combination of isotachophoresis (ITP) and high-performance liquid chromatography (HPLC) to improve sample pretreatment and determination of phenolic compounds in wine was investigated. The ITP system provided an enhanced sample load capacity and served as a sample clean-up technique, HPLC performed a final separation of the analytes presented in samples. The phenolic components were separated by Discovery RP Amid C16 chromatography column using water-methanol-acetonitrile-orthophosphoric acid gradient. The identification of phenolic compounds was made by comparison of the retention data obtained for the standard mixture, pretreated sample and the sample spiked standard additions. Satisfactory recoveries for all components analysed were observed between 86.1 and 109.2%.

Chromatography, High Pressure Liquid↗

Assay of phenolic compounds in red wine by on-line combination of capillary isotachophoresis with capillary zone electrophoresis.

The on-line combination of capillary zone electrophoresis (CZE) with capillary isotachophoresis (ITP) increases significantly the separation capability and sensitivity of capillary electrophoresis. This technique was used for separation and quantification of fourteen selected natural constituents in red wine belonging to flavonoids and phenolic acids. The leading electrolyte (LE) in the ITP pre-separation step was 10 mM HCl of pH* 7.2 with Tris as counterion, the terminating electrolyte (TE) was 50 mM boric acid of pH* 8.2 (adjusted with barium hydroxide). The background electrolyte in the electrophoretic step contained 25 mM beta-hydroxy-4-morpholinopropanesulfonic acid (MOPSO), 50 mM Tris, 15 mM boric acid and 5 mM beta-cyclodextrin of pH* 8.5. The content of methanol in all electrolytes was 20% (v/v). For exact timing of the transfer of isotachophoretically stacked analyte zones into the CZE column and for the control of the residual amount of leading and terminating ITP electrolytes picric acid was used as coloured marker. The R.S.D. values (n = 6) ranged between approximately 0.1% (for 0.25 microg ml(-1) rutin) and approximately 11% (for 0.25 microg ml(-1) of quercitrin). Detection limits were 30 ng mi(-1) for phenolic acids, quercitrin and rutin, 100 ng ml(-1) for quercetin, kaempferol and epicatechin and 250 ng ml(-1) for catechin. A single analysis took 45 min.

Electrophoresis↗

Stacking phenomena in electromigration: From basic principles to practical procedures.

The review describes principles of procedures and techniques used in capillary zone electrophoresis for enhancement of sensitivity that are based on increasing analyte mass in its zone during the electromigration process, for which the term stacking is generally used. Attention is paid to intrinsic stacking in samples with low conductivity, transient isotachophoretic stacking applied in samples with high conductivity, and sweeping in micellar electrokinetic chromatography. Principles of these stacking schemes are explained, new procedures and instrumental arrangements are discussed, and all contributions involving stacking principles that have been published since the year 2000 are surveyed.

Chromatography, Micellar Electrokinetic Capillary↗

On-line coupling of capillary isotachophoresis and capillary zone electrophoresis for the determination of flavonoids in methanolic extracts of Hypericum perforatum leaves or flowers.

Five flavonoids (hyperoside, isoquercitrin, quercitrin, quercetin and rutin) were separated and determined in extracts of Hypericum perforatum leaves or flowers by capillary zone electrophoresis (CZE) with isotachophoretic (ITP) sample pre-treatment using on-line column coupling configuration. The background electrolyte (BGE) used in the CZE step was different from the leading and terminating ITP electrolytes but all the electrolytes contained 20% (v/v) of methanol. The optimal leading electrolyte was 10 mM HCl of pH* approximately 7.2 (adjusted with Tris) and the terminating electrolyte was 50 mM H3BO3 of pH* approximately 8.2 (adjusted with barium hydroxide). This operational system allowed to concentrate and pre-separate selectively the flavonoid fraction from other plant constituents before the introduction of the flavonoids into the CZE capillary. The BGE for the CZE step was 50 mM Tris buffer of pH* approximately 8.75 containing 25 mM N-[tris(hydroxymethyl)methyl]-3-aminopropanesulfonic acid as co-ion and 55 mM H3BO3 as complex-forming agent. The ITP-CZE method with spectrophotometric detection at 254 nm was suitable for the quantitation of the flavonoids in real natural samples; kaempferol was used as internal standard. The limit of detection for quercetin-3-O-glycosides was 100 ng ml(-1) and calibration curves were rectilinear in the range 1-10 microg ml (-1) for most of the analytes. The RSD values ranged between 0.9 and 2.7% (n=3) when determining approximately 0.07-1.2% of the individual flavonoids in dried medicinal plants.

Boric Acids↗

On-line coupling of capillary isotachophoresis and zone electrophoresis for the assay of phenolic compounds in plant extracts.

The combination of capillary isotachophoresis (ITP) and capillary zone electrophoresis (CZE) in the column coupling configuration was optimized in a mode where the electrolyte for the CZE step is different from the leading and terminating ITP electrolytes. Two colored markers, picric acid and 1-nitroso-2-naphthol, were used for exact timing of the transfer of isotachophoretically stacked analyte zones into the CZE column and for the control of the residual amount of the leading and terminating ITP electrolytes entering the CZE capillary together with the analytes, thus controlling the duration of transient ITP migration in the CZE capillary and ensuring good separation of the analytes and reproducibility of the migration times (relative standard deviations 1%). ITP-CZE was applied to the simultaneous assay of several cinnamic acid derivatives and flavonoids in methanolic extracts of Sambucus flowers and Crataegus leaves and flowers. The preconcentrating and cleansing effect of the ITP step allowed injection of relatively large sample volumes (30 microL). The limits of detection were approximately 20-50 ng x mL(-1) and 100 ng x mL(-1) for the acids and flavonoids, respectively ( thick similar 200-times lower compared to conventional CE) with spectrophotometric detection at 254 nm. The ITP-CZE exhibited satisfactory linearity and precision when using CZE buffer of pseudo "pH" 9.0; 1-nitroso-2-naphthol was employed as the internal standard. The separation took approximately 35 min. The ITP-CZE results for rutin, hyperoside, and vitexin-2-O"-rhamnoside were in good accordance with those obtained previously by high-performance liquid chromatography.

Electrolytes↗