PubMed Health⌕ Search

Biomedical subjects

Margaret Strieper

Publications and source records attributed to Margaret Strieper.

3 recordsLinked to original sources

Initial experience with cardiac resynchronization therapy for ventricular dysfunction in young patients with surgically operated congenital heart disease.

Data regarding cardiac resynchronization therapy (CRT) in pediatric patients are limited. The first reported use of CRT in a young patient with congenital heart disease showed promising early results with improvement in New York Heart Association classification, aerobic capacity, and ventricular contractility 1 month after implant. Other reports have shown acute benefits of CRT in young patients with postoperative right bundle branch block after surgery for congenital heart defects. To date, however, there are no published data regarding CRT for the long-term management of systemic ventricular dysfunction in the young with associated congenital heart disease. This report describes our initial experience with CRT in these patients.

Adolescent↗

Efficacy of atrial antitachycardia pacing using the Medtronic AT500 pacemaker in patients with congenital heart disease.

Patients with congenital heart disease are vulnerable to atrial tachyarrhythmias, especially after atrial surgeries. We evaluated the efficacy of atrial arrhythmia detection and antitachycardia pacing (ATP) using the Medtronic AT500 pacemaker in 28 patients with congenital heart disease (age 30 +/- 18 years). Of 15 patients with atrial arrhythmias, 14 had atrial tachycardia events that were appropriately detected. ATP was enabled for 167 treatable episodes, successfully converting 90 (54%). Rhythms classified as ventricular tachycardia were detected 127 times, yet most were actually atrial or sinus tachycardia with 1:1 atrioventricular conduction. Atrial tachycardias in congenital heart disease are amenable to ATP algorithms in the AT500 pacemaker.

Adolescent↗

Evaluation of myocardial performance with conventional single-site ventricular pacing and biventricular pacing in a canine model of atrioventricular block.

INTRODUCTION: The aim of this study was to evaluate epicardial biventricular pacing as a means of maintaining synchronous ventricular activation in an acute canine model of AV block with normal ventricular anatomy and function. Chronic single-site ventricular pacing results in dyssynchronous ventricular activation and may contribute to ventricular dysfunction. Biventricular pacing has been used successfully in adult patients with congestive heart failure. METHODS AND RESULTS: This was an acute study of open chest mongrel dogs (n = 13). ECG, left ventricular (LV), aortic, and pulmonary arterial pressures were measured. LV impedance catheters were used to assess cardiodynamics using instantaneous LV pressure-volume relations (PVR). Following radiofrequency ablation of the AV node, a temporary pacemaker was programmed 10 beats/min above the intrinsic atrial rate, with an AV interval similar to the baseline intrinsic PR interval. The pacing protocol consisted of 5-minute intervals with the following lead configurations: right atrium-right ventricular apex (RA-RVA), RA-LV apex (LVA), and RA-biventricular using combinations of four ventricular sites (RVA, RV outflow tract [RVOT], LVA, LV base [LVB]). RA-RVA was used as the experimental control. LV systolic mechanics, as measured by the slope of the end-systolic (Ees) PVR (ESPVR, mmHg/cc), was statistically greater (P < 0.05) with all modes of biventricular pacing (RA-RVA/LVA 20.0 +/- 2.9, RA-RVA/LVB 18.4 +/- 2.9, RA-RVOT/LVA 15.1 +/- 1.8, RA-RVOT/LVB 17.6 +/- 2.9) compared to single-site ventricular pacing (RA-RVA 12.8 +/- 1.6). Concurrent with this improvement in myocardial performance was a shortening of the QRS duration (RA-RVA 97.7 +/- 2.9 vs RA-RVA/LVA 75.7 +/- 4.9, RA-RVA/LVB 70.3 +/- 4.9, RA-RVOT/LVA 65.3 +/- 4.4, and RA-RVOT/LVB 76.7 +/- 5.9, P < 0.05). CONCLUSION: In this acute canine model of AV block, QRS duration shortened and LV performance improved with epicardial biventricular pacing compared to standard single-site ventricular pacing.

Animals↗