PubMed Health⌕ Search

Biomedical subjects

Margaret-Anne Harris

Publications and source records attributed to Margaret-Anne Harris.

4 recordsLinked to original sources

Pulse transit time changes observed with different limb positions.

Pulse transit time (PTT) is a non-invasive measure of arterial compliance. It can be used to assess instantaneous blood pressure (BP) changes in continual cardiovascular measurement such as during overnight respiratory sleep studies. In these studies, periodic changes in limb position can occur randomly. However, little is known about their possible effects on PTT monitored on the various limbs. The objective of this study was to evaluate PTT differences on all four limbs during two positional changes (lowering and raising of a limb). Ten healthy adults (seven male) with a mean age of 27.0 years were recruited in this study. The results showed that the limb that underwent a positional change had significant (p < 0.05) local PTT differences when compared to its nominal baseline value, whereas PTT changes in the other remaining limbs were insignificant (p > 0.05). The mean PTT value measured from a vertically-raised limb increased by 42.7 ms, while it decreased by 28.1 ms with a half-lowered limb. The PTT differences observed during positional change can be contributed to by the complex interactions between hydrostatic pressure changes, autonomic and local autoregulation experienced in these limbs. Hence the findings herein suggest that PTT is able to reflect local circulatory responses despite changes in the position of other limbs. This can be useful in prolonged clinical observations where limb movements are expected.

Adaptation, Physiological↗

Variability in time delay between two models of pulse oximeters for deriving the photoplethysmographic signals.

Pulse oximetry is commonly used as an arterial blood oxygen saturation (SaO2) measure. However, its other serial output, the photoplethysmography (PPG) signal, is not as well studied. Raw PPG signals can be used to estimate cardiovascular measures like pulse transit time (PTT) and possibly heart rate (HR). These timing-related measurements are heavily dependent on the minimal variability in phase delay of the PPG signals. Masimo SET Rad-9 and Novametrix Oxypleth oximeters were investigated for their PPG phase characteristics on nine healthy adults. To facilitate comparison, PPG signals were acquired from fingers on the same hand in a random fashion. Results showed that mean PTT variations acquired from the Masimo oximeter (37.89 ms) were much greater than the Novametrix (5.66 ms). Documented evidence suggests that 1 ms variation in PTT is equivalent to 1 mmHg change in blood pressure. Moreover, the PTT trend derived from the Masimo oximeter can be mistaken as obstructive sleep apnoeas based on the known criteria. HR comparison was evaluated against estimates attained from an electrocardiogram (ECG). Novametrix differed from ECG by 0.71+/-0.58% (p<0.05) while Masimo differed by 4.51+/-3.66% (p>0.05). Modern oximeters can be attractive for their improved SaO2 measurement. However, using raw PPG signals obtained directly from these oximeters for timing-related measurements warrants further investigations.

Adult↗

Use of pulse transit time to distinguish respiratory events from tidal breathing in sleeping children.

STUDY OBJECTIVES: Currently, esophageal pressure monitoring is the "gold standard" measure for inspiratory efforts, but its invasive nature necessitates a better tolerated and noninvasive method to be used on children. Pulse transit time (PTT) has demonstrated its potential as a noninvasive surrogate marker for inspiratory efforts. The principle velocity determinant of PTT is the change in stiffness of the arterial wall and is inversely correlated to BP. Moreover, PTT has been shown to identify changes in inspiratory effort via the BP fluctuations induced by negative pleural pressure swings. In this study, the capability of PTT to classify respiratory events during sleep as either central or obstructive in nature was investigated. SETTING AND PARTICIPANTS: PTT measure was used in adjunct to routine overnight polysomnographic studies performed on 33 children (26 boys and 7 girls; mean +/- SD age, 6.7 +/- 3.9 years). The accuracy of PTT measurements was then evaluated against scored corresponding respiratory events in the polysomnography recordings. RESULTS: Three hundred thirty-four valid respiratory events occurred and were analyzed. One hundred twelve obstructive events (OEs) showed a decrease in mean PTT over a 10-sample window that had a probability of being correctly ranked below the baseline PTT during tidal breathing of 0.92 (p < 0.005); 222 central events (CEs) showed a decrease in the variance of PTT over a 10-sample window that had a probability of being ranked below the baseline PTT of 0.94 (p < 0.005). This indicates that, at a sensitivity of 0.90, OEs can be detected with a specificity of 0.82 and CEs can be detected with a specificity of 0.80. CONCLUSIONS: PTT is able to categorize CEs and OEs accordingly in the absence of motion artifacts, including hypopneas. Hence, PTT shows promise to differentiate respiratory events accordingly and can be an important diagnostic tool in pediatric respiratory sleep studies.

Abdomen↗

Sleep-related breathing disorder in Duchenne muscular dystrophy: disease spectrum in the paediatric population.

UNLABELLED: Duchenne muscular dystrophy (DMD) is a progressive neuromuscular disease with death usually occurring because of respiratory failure. Signs of early respiratory insufficiency are usually first detectable in sleep. OBJECTIVE: To study the presentation of sleep-related breathing disorder (SRBD) in patients with DMD. METHOD: A retrospective review of patients with DMD attending a tertiary paediatric sleep disorder clinic over a 5-year period. Symptoms, lung function and polysomnographic indices were reviewed. RESULTS: A total of 34 patients with DMD were referred for respiratory assessment (1-15 years). Twenty-two (64%) reported sleep-related symptomatology. Forced vital capacity (FVC) was between 12 and 107% predicted (n = 29). Thirty-two progressed to have polysomnography of which 15 were normal studies (median age: 10 years) and 10 (31%) were diagnostic of obstructive sleep apnoea (OSA) (median age: 8 years). A total of 11 patients (32%) showed hypoventilation (median age: 13 years) during the 5-year period and non-invasive ventilation (NIV) was offered to them. The median FVC of this group was 27% predicted. There was a significant improvement in the apnoea/hypopnoea index (AHI) (mean difference = 11.31, 95% CI = 5.91-16.70, P = 0.001) following the institution of NIV. CONCLUSIONS: The prevalence of SRBD in DMD is significant. There is a bimodal presentation of SRBD, with OSA found in the first decade and hypoventilation more commonly seen at the beginning of the second decade. Polysomnography is recommended in children with symptoms of OSA, or at the stage of becoming wheelchair-bound. In patients with the early stages of respiratory failure, assessment with polysomnography-identified sleep hypoventilation and assisted in initiating NIV.

Adolescent↗