PubMed Health⌕ Search

Biomedical subjects

Maria Augusta Raggi

Publications and source records attributed to Maria Augusta Raggi.

At least 37 records · Page 2Linked to original sources

Use of nano-liquid chromatography for the analysis of glycyrrhizin and glycyrrhetic acid in licorice roots and candies.

Glycyrrhizin (G) and glycyrrhetic acid (GA) were separated by using nano-liquid chromatography (nano-LC) in a fused silica capillary packed with RP18 stationary phase (75 microm ID, effective length 33 cm, packed 23 cm) eluting at 300 nL/min in a gradient mode. The mobile phase was a mixture of water-MeOH-MeCN-acetic acid (29:35:35:1, v/v/v/v) that was delivered for one minute and after this was modified by reducing the water content (14:42.5:42.5:1, v/v/v/v). The intra-day and inter-day relative standard deviations (of retention time and peak area) were satisfactory (lower than 2.9 and 4%, respectively). The linearity of the nano-LC method was assessed in the range 0.62-5.00 microg/mL and 80-200 microg/mL for GA and G, with R2 = 0.996 and 0.995, respectively. The licorice was extracted with a mixture of ethanol-water, diluted with the mobile phase, and injected for the analysis.

Chromatography, High Pressure Liquid↗

A rapid HPLC-DAD method for the analysis of fluoxetine and norfluoxetine in plasma from overdose patients.

There is a need for fast, simple and reliable analytical methods for the analysis of fluoxetine and norfluoxetine in patients who voluntarily or involuntarily have taken an overdose of the drug. A new liquid chromatographic method with diode array detection is presented herein for the determination of fluoxetine and its main active metabolite in human plasma for toxicological purposes. A mobile phase composed of acetonitrile and aqueous tetramethylammonium perchlorate allows to obtain the complete separation of the analytes on a C18 reversed phase column. The fast and accurate sample pre-treatment step is carried out by means of solid-phase extraction using hydrophilic-lipophilic balance cartridges and loading 100 microL of plasma only. This procedure gives satisfactory extraction yield values, as well as good plasma sample purification from matrix interference. Linearity was obtained in the 150-3000 ng/mL range for both analytes. Selectivity with respect to other psychotropic drugs was satisfactory. The method seems to be suitable for the analysis of fluoxetine and its metabolite in human plasma for depressed patients in overdose.

Antidepressive Agents, Second-Generation↗

Enantioselective determination of the novel antidepressant mirtazapine and its active demethylated metabolite in human plasma by means of capillary electrophoresis.

Mirtazapine is a recent noradrenergic and specific serotonergic antidepressant drug. A capillary electrophoretic method has been developed for the enantioseparation and analysis of mirtazapine and its main active metabolite, N-desmethylmirtazapine, in human plasma. For method optimisation several experimental parameters were investigated, such as type and concentration of the chiral selector, buffer pH and capillary temperature. Baseline enantioseparation of the analytes was achieved in 2.5 min in a fused silica capillary (50 microm i.d.; 48.5 cm total length; 8.5 cm effective length) using carboxymethyl-beta-cyclodextrin, dissolved in a background electrolyte consisting of 50 mM phosphate buffer at pH 2.5, as the chiral selector. UV detection was set at 205 nm. A careful pre-treatment of plasma samples was developed, using solid-phase extraction with hydrophilic-lipophilic balance cartridges (60 mg, 3 mL), eluting the sample with methanol, then concentrating it 37.5 times before injection. Extraction yield values are very satisfactory, being the average 89% for mirtazapine and 73% for N-desmethylmirtazapine. Application of the method to some human plasma samples has given satisfactory results.

Antidepressive Agents↗

Separation of ethoxylated bisphenol A dimethacrylates in dental composite after derivatisation to ionisable amines by capillary zone electrophoresis.

Bisphenol A ethoxylate dimethacrylates (Bis-EMA) are transformed into ionisable amines by derivatisation in order to make the analytes applicable to capillary electrophoresis. For this goal, piperidine was added onto the C=C double bond of the alpha,beta-unsaturated ester group forming a tertiary amine with pKa values between 9 and 10. Formation of the derivatives was confirmed by electrospray ionisation MS. Commercial Bis-EMA is a mixture of homologues with different number of ethoxy groups; it is characterised by the average number of the ethoxy groups in the chains. These homologues were resolved by capillary zone electrophoresis at pH 4. It is shown for the product with an average of four ethoxy groups per Bis-EMA molecule that about seven homologues can be baseline separated when differing by only one ethoxy group. For Bis-EMA with 30 ethoxy groups in average, about 23 homologues could be differentiated. The high resolution power of capillary zone electrophoresis enables characterisation of commercial dental composite material concerning the Bis-EMA constituents.

Amines↗

Simultaneous liquid chromatographic analysis of catecholamines and 4-hydroxy-3-methoxyphenylethylene glycol in human plasma. Comparison of amperometric and coulometric detection.

The comparison of two HPLC methods, one with electrochemical detection and the other with coulometric detection, for the simultaneous analysis of catecholamines and 4-hydroxy-3-methoxyphenylethylene glycol (MHPG) in human plasma is presented. The careful pre-treatment of plasma samples is based on an innovative two-step procedure by means of solid-phase extraction (SPE) which uses one single hydrophilic-lipophilic balance cartridge. The extraction yield values found were higher than 85% for epinephrine, norepinephrine and MHPG, and higher than 70% for dopamine. The assays carried out on real plasma samples with the coulometric system gave good results in terms of sensitivity (limits of quantitation: 0.10-0.15 ng ml(-1) for catecholamines, 0.6 ng ml(-1) for MHPG) and selectivity, while interference was sometimes found when using the amperometric system. Precision was also satisfactory, with relative standard deviation values for intermediate precision always lower than 6%. The HPLC method with coulometric detection coupled to a novel SPE procedure is thus suitable for the simultaneous determination of catecholamines and MHPG in plasma of volunteers subjected to experimental stress.

Case-Control Studies↗

High-performance liquid chromatographic determination of Levetiracetam in human plasma: comparison of different sample clean-up procedures.

An accurate and precise high-performance liquid chromatographic method using diode array detection for the determination of the novel antiepileptic, Levetiracetam, has been developed. Three clean-up procedures for the analysis of Levetiracetam in human plasma were implemented and evaluated, namely solid-phase extraction, deproteinization by addition of organic solvents and formation of insoluble salts. Adenosine was used as the internal standard for all three sample pretreatment procedures. Among the several cartridges used for solid-phase extraction, the hydrophilic-lypophilic balance (Oasis) HLB) phase provides the best extraction yield of Levetiracetam, together with high precision. With the two other clean-up procedures involving plasma deproteinization by addition of methanol or zinc sulphate, lower sensitivity and precision of the assays were obtained. However, they are cheaper and faster when compared with the solid-phase extraction procedure.

Anticonvulsants↗

Reversed-phase capillary electrochromatography for the simultaneous determination of acetylsalicylic acid, paracetamol, and caffeine in analgesic tablets.

The separation and simultaneous determination of caffeine, paracetamol, and acetylsalicylic acid in two analgesic tablet formulations was investigated by capillary electrochromatography (CEC). The effect of mobile phase composition on the separation and peak efficiency of the three analytes was studied and evaluated; in particular, the influence of buffer type, buffer pH, and acetonitrile content of the mobile phase was investigated. The analyses were carried out under optimized separation conditions, using a full-packed silica capillary (75 microm ID; 30.0 cm and 21.5 cm total and effective lengths, respectively) with a 5 microm C8 stationary phase. A mixture of 25 mM ammonium formate at pH 3.0 and acetonitrile (30:70 v/v) was used as the mobile phase. UV detection was at 210 nm. Good linearity was found in the range of 50-200, 20-160, and 4-20 microg/mL for acetylsalicylic acid (r2=0.9988), paracetamol (r2=0.9990) and caffeine (r2=0.9990), respectively. Intermediate precision (RSD interday) as low as 0.1-0.8% was found for retention times, while the RSD values for the peak area ratios (Aanalyte/AIS) were in the range of 1.9-2.9%. The optimized CEC method was applied to the analysis of the studied compounds present in commercial tablets.

Acetaminophen↗

Monolithic columns with a gradient of functionalities prepared via photoinitiated grafting for separations using capillary electrochromatography.

Stationary phases for capillary electrochromatography with a longitudinal gradient of functionalities have been prepared via photoinitiated grafting of polymer chains onto the pore surface of a porous polymer monolith. In order to achieve the desired retention and electroosmotic flow, the hydrophobic poly(butyl methacrylate-co-ethylene dimethacrylate) monolith with optimized porous properties was grafted with a layer of ionizable polymer, poly(2-acrylamido-2-methyl-1-propanesulfonic acid). A moving shutter and a neutral density filter were used to control the dose of UV light received at different locations along the monolith in order to create the longitudinal gradient of functionalities. Formation of the desired gradients was confirmed using electron probe microanalysis of different locations along the column. The preparation technique significantly affects performance in the CEC mode as demonstrated on the separations of a model mixture using columns both with homogeneous distribution of grafts and with a gradient of functionality. Columns grafted with the gradient of functionalities were found superior to those functionalized uniformly. A comparison of the performance of the gradient column with another containing evenly distributed functionalities showed the performance benefits of the "gradient" column.

Electrochemistry↗

Aggressive responding in abstinent heroin addicts: neuroendocrine and personality correlates.

Objective measures of experimentally induced aggressiveness were evaluated in 20 abstinent heroin-dependent subjects, in comparison with 20 normal healthy male subjects. All the subjects were preliminarily submitted to DSM-IV interviews, Buss-Durkee Hostility Inventory (BDHI) and Minnesota Multiphasic Personality Inventory (MMPI II). During a laboratory task, the Point Subtraction Aggression Paradigm (PSAP), subjects earned monetary reinforcers with repeated button presses and were provoked by the subtraction of money, which was attributed to a fictitious other participant. Subjects could respond by ostensibly subtracting money from the fictitious subject (the aggressive response). Money-earning responses were not different in drug-free heroin addicts and controls during the first two sessions and significantly lower during the third session in heroin-dependent subjects (t=2.99, P<.01). Aggressive responses were significantly higher (F=4.9, P<.01) in heroin addicted individuals, in comparison with controls. During the experimentally induced aggressiveness, plasma adrenocorticotropic hormone (ACTH) and cortisol (CORT) concentrations increased less significantly, and norepinephrine (NE) and epinephrine (EPI) levels, together with heart rate (HR), increased more significantly in abstinent heroin-dependent subjects than in healthy subjects. PSAP aggressive responses positively correlated with catecholamine changes, BDHI "direct" and "irritability" scores, MMPI "psychopathic deviate" scores in heroin-dependent subjects and controls, and with CORT responses only in healthy subjects. No correlation was found between heroin-exposure extent (substance abuse history duration) and aggressiveness levels. The present findings suggest that heroin-dependent patients have higher outward-directed aggressiveness than healthy subjects, in relation with monoamine hyperreactivity, after long-term opiate discontinuation. Aggressiveness in heroin addicts seems to be related more to the personality traits than to drug effects. The impairment of hypothalamus-pituitary-adrenal (HPA) axis in abstinent addicted individuals could be due to a long-lasting action exerted by opiates on proopiomelanocortin (POMC) or to a premorbid psychobiological condition, in association with increased sympathetic arousal.

Adrenocorticotropic Hormone↗

Atypical antipsychotics: pharmacokinetics, therapeutic drug monitoring and pharmacological interactions.

The development of new "atypical" antipsychotic agents, which are safer than classical neuroleptics and also active against the negative symptoms and neurocognitive deficits caused by the illness, has produced a significant advancement in the treatment of schizophrenia. The atypical (or "second generation") antipsychotics have several therapeutical properties in common, however they can significantly differ with regard to clinical potency and side effects. The main features regarding pharmacodynamics, pharmacokinetics and pharmacological interactions of the most important atypical antipsychotics, namely clozapine, olanzapine, quetiapine and risperidone, are treated herein. Several analytical methods available for the therapeutic drug monitoring of these drugs are also presented, as well as the novel formulations, which can notably improve the therapy of schizophrenia. Other very recent atypical agents, such as ziprasidone, aripiprazole, iloperidone, sertindole and zotepine will also be briefly described.

Antipsychotic Agents↗

Quality control of commercial tablets containing the novel antipsychotic quetiapine.

Quetiapine (bis [2-(2-[4-(dibenzo[b,f][1,4]thiazepin-11-yl]ethoxy)ethanol]fumarate) is the most recent agent introduced on the drug market for the treatment of psychotic disorders. Two different analytical methods for the quality control of quetiapine in commercial formulations have been developed and compared: a spectrophotometric method and a capillary zone electrophoretic (CZE) method. The spectrophotometric assay was carried out measuring the absorbance at a wavelength of 246 nm. The CZE method used an uncoated fused-silica capillary and a pH 2.5, 50 mM phosphate buffer as the background electrolyte. The detection wavelength was 205 nm, the separation voltage was 15 kV, and a complete electrophoretic run lasts less than 2.5 min. Extraction of quetiapine from the commercial tablets consisted of a simple one-step treatment with a pH 2.5, 50 mM phosphate buffer. Linearity was observed in the 5-25 microg ml(-1) concentration range of quetiapine for the spectrophotometric method, and in the 5-50 microg ml(-1) concentration range for the electrophoretic method. Both methods gave satisfactory results in terms of repeatability and intermediate precision (RSD<1.9%). Also accuracy values were very good for both methods, the recovery being between 98.2 and 100.5%.

Antipsychotic Agents↗

Liquid chromatographic analysis of the cis(Z)- and trans(E)-isomers of clopenthixol in human plasma using a novel solid phase extraction procedure.

A simple and highly sensitive high-performance liquid chromatographic (HPLC) method for the simultaneous determination of cis(Z)-clopenthixol and trans(E)-clopenthixol in human plasma has been developed. The chromatographic analysis was carried out isocratically on a reversed-phase column (C(8) 150 x 4.6 mm I.D., 5 microm) using a mixture of 25 mM phosphate buffer and acetonitrile (65:35 v/v, pH* 3.0) as the mobile phase, and ultraviolet detection at 230 nm. Plasma sample pretreatment was accomplished by means of an original solid-phase extraction (SPE) procedure carried out on cyanopropyl cartridges, with a high extraction yield and good selectivity. Under the optimum conditions, calibration graphs of spiked human plasma samples were obtained over the concentration ranges 1-300 ng ml(-1) for cis(Z)-clopenthixol and 1-200 ng ml(-1) for trans(E)-clopenthixol. The limit of detection (LOD) was 0.3 ng ml(-1) for both cis(Z)- and trans(E)-isomers of clopenthixol. The method was successfully applied to the determination of cis(Z)-clopenthixol and trans(E)-clopenthixol in plasma samples of schizophrenic patients undergoing therapy with zuclopenthixol.

Antipsychotic Agents↗

Determination of progesterone in commercial formulations and in non conventional micellar systems.

Progesterone was determined in commercial pharmaceutical formulations and experimental micellar systems by means of two analytical methods based on liquid chromatography and derivative spectrophotometry. The chromatographic analysis, with ultraviolet detection at 245 nm, was carried out on a C8 column using a mobile phase composed of 2-propanol and a pH 2.5, 30 mM phosphate buffer. Derivative spectrophotometry (DS) used the difference between the values of the first derivative at 227.2 and 253.6 nm. Both methods require only a simple extraction procedure of progesterone from the formulations before analysis. The high-performance liquid chromatography (HPLC) procedure allows for the quantitative determination of progesterone in all pharmaceutical formulations tested (oily and alcoholic injectable solutions, gel preparations and soft capsules) and also of the newly-developed polymeric micellar system. On the contrary, the derivative spectrophotometric method is not suitable for the pharmaceutical formulation containing estradiol and for the new micellar systems. The results obtained with the two methods are in good agreement and always satisfactory in terms of precision and accuracy.

Chemistry, Pharmaceutical↗

Quantitation of oxcarbazepine and its metabolites in human plasma by micellar electrokinetic chromatography.

A reliable micellar electrokinetic chromatographic method for the determination of oxcarbazepine and its two main metabolites, 10-hydroxycarbamazepine and 10,11-trans-dihydroxy-10,11-dihydroxycarbamazepine, in human plasma was developed. The separation and determination of the analytes was achieved using a system consisting of 60 mM SDS in phosphate buffer (30 mM, pH 8.0), to which 20% (v/v) methanol was added. Separation was carried out in an uncoated fused-silica capillary with a separation voltage of 25 kV and currents typically less than 40 microA. Spectrophotometric detection was at 205 nm. Isolation of oxcarbazepine and its metabolites from plasma was accomplished by a solid-phase extraction procedure. The mean extraction yield of the analytes from plasma was higher than 94%. The linear correlation coefficients were better than 0.994 for all analytes. The limit of detection was 0.05 microg/mL, the limit of quantitation 0.15 microg/mL. The repeatability for the spiked blank plasma samples was lower than 1.9% and the intermediate precision lower than 2.1%, both expressed as RSD%. The results obtained analysing real plasma samples from epileptic patients under therapy with Tolep were satisfactory in terms of precision, accuracy and detectability.

Anticonvulsants↗

Microemulsion electrokinetic chromatography applied for separation of levetiracetam from other antiepileptic drugs in polypharmacy.

Microemulsion electrokinetic chromatography was applied for the separation of levetiracetam from other antiepileptic drugs (primidone, phenobarbital, phenytoin, lamotrigine and carbamazepine) that are potentially coadministered in therapy of patients. The influence of the composition of the microemulsion system (with sodium dodecyl sulfate as charged surfactant) was investigated, modifying the kind of cosurfactant (lower alcohols from C3 to C5), the pH (and salinity) of the aqueous background electrolyte, and the ratio of aqueous phase to organic constituents forming the microdroplets of the oil-in-water emulsion. Separation selectivity was depending on all these parameters, resulting even in changes of the migration sequence of the analytes. Only moderate correlation was observed for the microemulsion system compared with a micellar system, both consisting of the aqueous borate buffer (pH 9.2) and SDS as micelle former (linear correlation coefficient for analyte mobilities is 0.974). The sample solvent plays an important role on the shape of the resulting chromatograms: methanol at concentrations higher than 35% impairs peak shape and separation efficiency. The microemulsion method (with 93.76% aqueous borate buffer (pH 9.2, 10 mM), 0.48% n-octane, 1.80% SDS, 3.96% 1-butanol, all w/w) is suitable for the determination of levetiracetam in human plasma (combined with a sample pretreatment based on solid-phase extraction).

Anticonvulsants↗

Emotional perception and neuroendocrine changes.

The present study was designed to investigate the neuroendocrine modifications during affective states. In particular, we investigate if the pleasantness of the stimuli has a different effect on neuroendocrine responses. To address this issue, we compared the effects of pleasant, neutral, and unpleasant pictures on catecholamine, adrenocorticotrophic hormone (ACTH), cortisol, and prolactin plasma levels. Ten male participants were submitted to three experimental sessions, each on one of the three experimental days, a week apart in a counterbalanced order. Although in the subjective arousal rating, pleasant (erotic pictures) and unpleasant stimuli (pictures of mutilated bodies) receive the same high score, a different neuroendocrine pattern was obtained: unpleasant stimuli elicited a decrease in prolactin concentration and increases in noradrenaline, cortisol, and ACTH levels, whereas pleasant slide set viewing induced an increase in prolactin levels. The results suggest that the neuroendocrine system responds selectively to affective motivationally relevant pictures.

Adrenocorticotropic Hormone↗

Determination of melatonin in galenic preparations by LC and voltammetry.

The amount of melatonin in galenic tablets was determined by means of two feasible and accurate analytical methods. The high performance liquid chromatography (HPLC) with ultraviolet detection at 223 nm used a C(18) reversed-phase column; the linear scan voltammetric procedure (LSV) employs a pH 3.0 phosphate buffer as the supporting electrolyte for the oxidation process of melatonin, which has a current intensity maximum at +850 mV. The two methods gave satisfactory results in terms of precision and accuracy. In fact, the data of repeatability and intermediate precision expressed as percentage relative standard deviations (RSD%) were < or =2.8 and the accuracy values, resulting from recovery experiments, were between 99.0 and 101.3%. Both methods are suitable for quality control of melatonin in galenic preparations; the LSV procedure is more rapid, the HPLC method is more sensitive and more precise.

Antioxidants↗

Separation of carbamazepine and five metabolites, and analysis in human plasma by micellar electrokinetic capillary chromatography.

A rapid and feasible method was developed for the analysis of carbamazepine and its five metabolites (10,11-dihydro-10,11-epoxycarbamazepine, 10,11-dihydro-10,11-dihydroxycarbamazepine, 10,11-dihydro-10-hydroxycarbamazepine, 2-hydroxycarbamazepine and 3-hydroxycarbamazepine) in human plasma. Separation of the analytes is based on micellar electrokinetic chromatography, in untreated fused-silica capillary (48.5/40.0 cm length, 50 microm I.D.) with phosphate buffer (30 mM, pH 8.00) as background electrolyte, containing 50 mM sodium dodecylsulfate, and methanol (15%, v/v) as organic modifier. Clean up of human plasma samples was carried out by means of a solid-phase extraction procedure, which gave a high extraction yield for all six carbamazepines (>88%). The overall precision of the method gives a mean RSD of about 1.8%. The limit of quantitation for all analytes is < or = 0.30 microg ml(-1), the limit of detection < or = 0.12 microg ml(-1).

Anticonvulsants↗