PubMed Health⌕ Search

Biomedical subjects

Maria Claudina Camargo de Andrade

Publications and source records attributed to Maria Claudina Camargo de Andrade.

3 recordsLinked to original sources

Expression and localization of N-domain ANG I-converting enzymes in mesangial cells in culture from spontaneously hypertensive rats.

The angiotensin-converting enzyme (ACE) profile in urine of hypertensive patients and spontaneously hypertensive rats (SHR; 90- and 65-kDa N-domain ACEs) is different from that of healthy subjects and Wistar rats (190 and 65 kDa). In addition, four ACE isoforms were purified from mesangial cells (MC) of Wistar rats in the intracellular compartment (130 and 68 kDa) and as secreted forms (130 and 60 kDa). We decided to characterize ACE forms from SHR MC in culture. Analysis of the ACE gene showed that SHR MC are able to express ACE mRNA. The concentrated medium and cell homogenate were separately purified by gel filtration and then subjected to lisinopril-Sepharose chromatography. The molecular masses of purified enzymes, 90 kDa for ACEm1A and 65 kDa for ACEm2A (secreted enzymes) and 90 kDa for ACEInth1A and 65 kDa for ACEInth2A (intracellular), were different from those of Wistar MC. The purified enzymes are Cl- dependent, inhibited by enalaprilat and captopril, and able to hydrolyze AcSDKP. Immunofluorescence and cell fractionation followed by Western blotting showed predominant immunoreaction of the 9B9 antiserum for N-domain ACE in the nuclei. The N-domain ACE was localized in the glomerulus from Wistar rats and SHR. ANG II and ANG-(1-7) were localized in the cell cytoplasm and nuclei. The 90-kDa N-domain ACE, described recently as a possible genetic marker of hypertension, was found inside the cell nuclei of SHR MC colocalized with ANG II and ANG-(1-7). The presence of ANG II in the cell nuclei could suggest an important role for this peptide in the transcription of new genes.

Angiotensin II↗

Sirolimus quantification by high-performance liquid chromatography with ultraviolet detection.

The need to adapt optimal conditions of sirolimus blood level monitoring in laboratories led us to optimize an high-performance liquid chromatography-ultraviolet method and compare the elution performances using the mobile phase A, 68% MeOH/2% acetonitrile (ACN)/30% H(2)O and mobile phase B, 30% MeOH/42% ACN/28% H(2)O. Samples were assayed with 1-chlorobutane, redissolved in MeOH/water and injected onto a C-18 column at 50 degrees C. The assay achieved sensitivity of 2.5-150 ng/ml (CV = 10.6%) and recovery of 92-103.6%. The intra- and interassay precisions ranged from 3.3% to 13% and from 5.9% to 15% for quality controls of 7.5, 60 and 120 ng/ml. The mobile phase A was unable to elute and recover sirolimus and internal standard in the expected retention time and concentration. Under our working conditions, the assay was precise, accurate and sensible, stressing the importance of establishing for the best working conditions according to the staff and demands of the laboratory.

Chromatography, High Pressure Liquid↗

Determination of sirolimus blood concentration using high-performance liquid chromatography with ultraviolet detection.

BACKGROUND: Different HPLC methods have been developed and used to determined sirolimus blood concentrations. These methods show different performance characteristics, mostly related to peak interference, recovery, assay sensitivity, and turnaround times. OBJECTIVE: We adapted, improved, and validated an HPLC method with UV detection for measurement of sirolimus in whole blood clinical samples. METHODS: The standards, quality controls, or patient samples (0.25 or 0.5 mL) and internal standard (desmethoxysirolimus) were extracted with 1-chlorobutane. After evaporation, the extract was reconstituted in a 70% acetonitrile/water mixture and analyzed onto a reverse-phase C18 column at 50 degrees C under a flow rate of 1.0 mL/min in the HPLC system. Ultraviolet detection was performed at 278 nm, with sensitivity setting of 0.010 AUFS. Identification of peaks of interest was by retention time; quantification of sirolimus was based on a peak area ratio. RESULTS: Analytic recovery ranging from 96 to 120% (CV = 3.7 to 16.8%; bias = -4.2 to 16.7%) was observed throughout the assay's linear range (2.5-150.0 ng/mL). The lower limit of quantification for both sample volumes (0.25 or 0.5 mL) was 2.5 ng/mL (CV = 12 and 15%, bias = -1.2 and 4%, respectively). The intra- and interassay imprecision ranged from 6.2 to 14.4% and from 9.1 to 18.6%, with bias ranging from 1.3 to 12.9% and -1.8% to 7.1, for quality control levels of 3, 10, and 20 ng/mL. Whole blood and extracted samples are stable at room temperature and at 4 and -20 degrees C for 1 week and 3 days, respectively. Chromatograms showed good separation free of interfering peaks. A set of 45 samples can be extracted in 2 h, allowing results within 24 h. CONCLUSION: This HPLC-UV method shows good and reproducible performance, satisfying all requirements of an assay designated to be applied in therapeutic drug monitoring strategies after organ transplantation.

Chromatography, High Pressure Liquid↗