Fast retrospectively gated quantitative four-dimensional (4D) cardiac micro computed tomography imaging of free-breathing mice.

OBJECTIVE: We sought to demonstrate retrospectively gated dynamic 3D cardiac micro computed tomography (CT) of free-breathing mice. MATERIALS AND METHODS: Five C57Bl6 mice were scanned using a cone-beam scanner with a slip-ring-mounted flat-panel detector. After the injection of an intravascular iodinated contrast agent, projection images were acquired over the course of 50 seconds, while the scanner rotated through 10 complete rotations. The mouse respiratory and electrocardiogram signals were recorder simultaneously with image acquisition. After acquisition, the projection images were retrospectively sorted into projections belonging to different cardiac time points, occurring only during expiration. RESULTS: Dynamic 3D cardiac images, with isotropic 150-microm voxel spacing, were reconstructed at 12-millisecond intervals throughout the cardiac cycle in all mice. The average ejection fraction and cardiac output were 58.2+/-4.6% and 11.4+/-1.3 mL/min, respectively. The measured entrance dose for the entire scan was 28 cGy. Repeat scans of the same animals showed that intrasubject variability was smaller than intersubject variability. CONCLUSIONS: We have developed a high-resolution micro computed tomography method for evaluating the cardiac function and morphology of free-breathing mice in acquisition times shorter than 1 minute.

Animals↗

Delayed enhancement magnetic resonance imaging predicts response to cardiac resynchronization therapy in patients with intraventricular dyssynchrony.

OBJECTIVES: We evaluated the ability of delayed enhancement magnetic resonance imaging (DE-MRI) to predict clinical response to cardiac resynchronization therapy (CRT). BACKGROUND: Cardiac resynchronization therapy reduces morbidity and mortality in selected heart failure patients. However, up to 30% of patients do not have a response. We hypothesized that scar burden on DE-MRI predicts response to CRT. METHODS: The DE-MRI was performed on 28 heart failure patients undergoing CRT. Patients with QRS > or =120 ms, left ventricular ejection fraction < or =35%, New York Heart Association functional class II to IV, and dyssynchrony > or =60 ms were studied. Baseline and 3-month clinical follow-up, wall motion, 6-min walk, and quality of life assessment were performed. The DE-MRI was performed 10 min after 0.20 mmol/kg intravenous gadolinium. Scar measured by planimetry was correlated with response criteria. RESULTS: Twenty-three patients completed the protocol (mean age 64.9 +/- 11.7 years), with 12 (52%) having a history of myocardial infarction. Thirteen (57%) patients met response criteria. Percent total scar was significantly higher in the nonresponse versus response group (median and interquartile range of 24.7% [18.1 to 48.7] vs. 1.0% [0.0 to 8.7], p = 0.0022) and predicted nonresponse by receiver-operating characteristic analysis (area = 0.94). At a cutoff value of 15%, percent total scar provided a sensitivity and specificity of 85% and 90%, respectively, for clinical response to CRT. Similarly, septal scar < or =40% provided a 100% sensitivity and specificity for response. Regression analysis showed linear correlations between percent total scar and change in each of the individual response criteria. CONCLUSIONS: The DE-MRI accurately predicted clinical response to CRT. This technique offers unique information in the assessment of patients referred for CRT.

Aged↗

Coronary x-ray angiographic reconstruction and image orientation.

We have developed an interactive geometric method for 3D reconstruction of the coronary arteries using multiple single-plane angiographic views with arbitrary orientations. Epipolar planes and epipolar lines are employed to trace corresponding vessel segments on these views. These points are utilized to reconstruct 3D vessel centerlines. The accuracy of the reconstruction is assessed using: (1) near-intersection distances of the rays that connect x-ray sources with projected points, (2) distances between traced and projected centerlines. These same two measures enter into a fitness function for a genetic search algorithm (GA) employed to orient the angiographic image planes automatically in 3D avoiding local minima in the search for optimized parameters. Furthermore, the GA utilizes traced vessel shapes (as opposed to isolated anchor points) to assist the optimization process. Differences between two-view and multiview reconstructions are evaluated. Vessel radii are measured and used to render the coronary tree in 3D as a surface. Reconstruction fidelity is demonstrated via (1) virtual phantom, (2) real phantom, and (3) patient data sets, the latter two of which utilize the GA. These simulated and measured angiograms illustrate that the vessel center-lines are reconstructed in 3D with accuracy below 1 mm. The reconstruction method is thus accurate compared to typical vessel dimensions of 1-3 mm. The methods presented should enable a combined interpretation of the severity of coronary artery stenoses and the hemodynamic impact on myocardial perfusion in patients with coronary artery disease.

Adult↗

Angle-independent measure of motion for image-based gating in 3D coronary angiography.

The role of three-dimensional (3D) image guidance for interventional procedures and minimally invasive surgeries is increasing for the treatment of vascular disease. Currently, most interventional procedures are guided by two-dimensional x-ray angiography, but computed rotational angiography has the potential to provide 3D geometric information about the coronary arteries. The creation of 3D angiographic images of the coronary arteries requires synchronization of data acquisition with respect to the cardiac cycle, in order to minimize motion artifacts. This can be achieved by inferring the extent of motion from a patient's electrocardiogram (ECG) signal. However, a direct measurement of motion (from the 2D angiograms) has the potential to improve the 3D angiographic images by ensuring that only projections acquired during periods of minimal motion are included in the reconstruction. This paper presents an image-based metric for measuring the extent of motion in 2D x-ray angiographic images. Adaptive histogram equalization was applied to projection images to increase the sharpness of coronary arteries and the superior-inferior component of the weighted centroid (SIC) was measured. The SIC constitutes an image-based metric that can be used to track vessel motion, independent of apparent motion induced by the rotational acquisition. To evaluate the technique, six consecutive patients scheduled for routine coronary angiography procedures were studied. We compared the end of the SIC rest period (rho) to R-waves (R) detected in the patient's ECG and found a mean difference of 14 +/- 80 ms. Two simultaneous angular positions were acquired and rho was detected for each position. There was no statistically significant difference (P = 0.79) between rho in the two simultaneously acquired angular positions. Thus we have shown the SIC to be independent of view angle, which is critical for rotational angiography. A preliminary image-based gating strategy that employed the SIC was compared to an ECG-based gating strategy in a porcine model. The image-based gating strategy selected 61 projection images, compared to 45 selected by the ECG-gating strategy. Qualitative comparison revealed that although both the SIC-based and ECG-gated reconstructions decreased motion artifact compared to reconstruction with no gating, the SIC-based gating technique increased the conspicuity of smaller vessels when compared to ECG gating in maximum intensity projections of the reconstructions and increased the sharpness of a vessel cross section in multi-planar reformats of the reconstruction.

Algorithms↗

Multisite trial of MR flow measurement: phantom and protocol design.

PURPOSE: To describe a portable, easily assembled phantom with well-defined bore geometry together with a series of tests that will form the basis of a standardized quality assurance protocol in a multicenter trial of flow measurement by the MR phase mapping technique. MATERIALS AND METHODS: The phantom consists of silicone polymer layers containing parallel straight and stenosed flow channels in one layer and a U-bend in a second layer, separated by hermetically sealed agarose slabs. The phantom is constructed by casting low melting-point metal in an aluminum mold precisely milled to the desired geometry, and then using the low melting-point metal core as a negative around which the silicone is allowed to set. By melting out the metal, the flow channels are established. The milled aluminum mold is reusable, ensuring faithful reproduction of the flow geometry for all phantoms thus produced. The agarose layers provide additional loading and static background signal for background correction. With the use of the described phantom, one can evaluate flow measurement accuracy and repeatability, as well as the influence of several imaging geometry factors: slice offset, in-plane position, and slice-flow obliquity. RESULTS: The new phantom is compact and portable, and is well suited for reassembly. We were able to demonstrate its facility in a battery of tests of interest in evaluating MR flow measurements. CONCLUSION: The phantom is a robust standardized test object for use in a multicenter trial. Such a trial, to investigate the performance of MR flow measurement using the phantom and the tests we describe, has been initiated.

Blood Flow Velocity↗

Registration of two-dimensional cardiac images to preprocedural three-dimensional images for interventional applications.

PURPOSE: To evaluate the accuracy and efficiency of rigid-body registration of two-dimensional fast cine and real-time cardiac images to high-resolution and SNR three-dimensional preprocedural reference volumes for application during MRI-guided interventional procedures. MATERIALS AND METHODS: Mutual information (MI) and correlation ratio (CR) similarity measures were evaluated. The dependence of registration accuracy and efficiency on different resolution and SNR parameters, and also on cardiac-phase differences was evaluated in a porcine model. Two-dimensional images were initially misoriented at distances (d) of 2-10 mm, and rotations of +/-5 degrees about all axes. Registration error and computation time were evaluated, and performance was also assessed visually. RESULTS: The maximum registration error using MI (<2.7 mm and <3.6 degrees ) occurred for d = 10 mm, misrotation of +/-5 degrees , and relative SNR = 1. The computation time was 15 seconds for MI and 10 seconds for CR. CONCLUSION: Registration accuracy was not highly dependent on the relative timing, within the cycle, between the two-dimensional and three-dimensional images. Registration using CR was faster than that using MI, although accuracy was marginally higher with MI. J.

Algorithms↗

Using the axis of rotation of polar navigator echoes to rapidly measure 3D rigid-body motion.

An improved technique to prospectively correct three-dimensional rigid-body motion using polar spherical navigator (pNAV) echoes is presented. The technique is based on acquiring pNAVs of an object in a baseline and rotated position and determining the axis of rotation (AOR) between data sets, thereby reducing 3D rotations to a 2D, planar rotation. Finding the AOR is simplified by prerotating the baseline trajectory, which forces the axis to lie within a specific polar region of a spherical shell in k-space. Orbital navigator echoes are interpolated from the pNAV data in planes orthogonal to the AOR and cross-correlated to determine the 2D rotation. The rotation about the AOR is used in conjunction with its orientation to calculate the overall 3D rotation. The pNAV-AOR technique was tested for its precision, accuracy, and processing speed in detecting compound rotations and translations of varying magnitude. In comparison to the spherical navigator echo technique, the pNAV-AOR technique is noniterative, fast, and independent of rotation magnitude and direction. At low SNR, the technique can detect compound rotations to 0.5 degrees accuracy in an estimated 100 msec, indicating that prospective 3D rigid-body motion correction may be feasible with this technique.

Humans↗

Optimizing spherical navigator echoes for three-dimensional rigid-body motion detection.

Spherical navigator (SNAV) echoes show promise in correcting for three-dimensional rigid-body motion. In this paper, several important parameters in the design and performance of the SNAV technique are discussed, including a novel sampling strategy, the optimal k-space radius and sampling density of the navigator, and the execution of the SNAV trajectory by the scanner hardware. A variable-sampling density (VSD) helical-spiral SNAV trajectory, which can acquire data on the entire spherical shell without exceeding the maximum slew rate of the scanner, is presented. To ensure that the VSD SNAV trajectory was properly executed by the scanner hardware, the gradient waveforms were verified using a self-encoding technique. The ability of the VSD SNAV to measure rotational and translational motion was studied with in vitro experiments at various k-space radii and sampling densities. The results of this study show that the best accuracy was attained at k-space radii of 1.4 and 1.6 cm(-1), with 2400 to 4000 samples acquired over the sphere.

Algorithms↗

En bloc exclusion of the pulmonary vein region in the pig using off pump, beating, intra-cardiac surgery: a pilot study of minimally invasive surgery for atrial fibrillation.

BACKGROUND: Off-pump, closed, beating heart, minimally-invasive surgery in patients with lone atrial fibrillation (AF) must be effective to become the preferred alternative to catheter ablation. Because of the inherent anatomical limitations of the epicardial access, we explored the feasibility of an intracardiac approach. METHODS: We report an acute study of en bloc, cryo-exclusion of the pulmonary vein region in 7 pigs. The left atrial appendage (LAA) was approached via a left thoracotomy. Electrodes were attached to the posterior wall of the left atrium (LPA) and right atrial appendage (RAA) for pacing and electrophysiological monitoring. A modified Surgifrost probe was introduced via the LAA and positioned using transesophageal (TEE) and intracardiac (ICE) echocardiographic guidance to generate encircling cryolesions (3 minutes, -105 degrees C) of the pulmonary vein region. RESULTS: A complete two-way block was achieved in 6 pigs and an incomplete block in 1. The excluded segment had very slow idiosyncratic rhythm or was electrically silent. In all pigs before isolation, sustained AF was inducible with the most rapid rhythms and fractionated electrograms recorded from the LA. While sustained AF was induced before exclusion, it was not after isolation in either the exclude or non-excluded segments. All tissue samples taken along the encircling cryolesions had transmural cryolesions on pathological examination. CONCLUSIONS: We conclude that off-pump, closed heart, beating, intracardiac AF surgery is feasible, reliable and can duplicate the accuracy and precision of the open-heart approach. However, further developments are needed to make this novel approach an alternative to current approaches for catheter ablation.

Animals↗

Prospective respiratory-gated micro-CT of free breathing rodents.

Microcomputed tomography (Micro-CT) has the potential to noninvasively image the structure of organs in rodent models with high spatial resolution and relatively short image acquisition times. However, motion artifacts associated with the normal respiratory motion of the animal may arise when imaging the abdomen or thorax. To reduce these artifacts and the accompanying loss of spatial resolution, we propose a prospective respiratory gating technique for use with anaesthetized, free-breathing rodents. A custom-made bed with an embedded pressure chamber was connected to a pressure transducer. Anaesthetized animals were placed in the prone position on the bed with their abdomens located over the chamber. During inspiration, the motion of the diaphragm caused an increase in the chamber pressure, which was converted into a voltage signal by the transducer. An output voltage was used to trigger image acquisition at any desired time point in the respiratory cycle. Digital radiographic images were acquired of anaesthetized, free-breathing rats with a digital radiographic system to correlate the respiratory wave form with respiration-induced organ motion. The respiratory wave form was monitored and recorded simultaneously with the x-ray radiation pulses, and an imaging window was defined, beginning at end expiration. Phantom experiments were performed to verify that the respiratory gating apparatus was triggering the micro-CT system. Attached to the distensible phantom were 100 microm diameter copper wires and the measured full width at half maximum was used to assess differences in image quality between respiratory-gated and ungated imaging protocols. This experiment allowed us to quantify the improvement in the spatial resolution, and the reduction of motion artifacts caused by moving structures, in the images resulting from respiratory-gated image acquisitions. The measured wire diameters were 0.135 mm for the stationary phantom image, 0.137 mm for the image gated at end deflation, 0.213 mm for the image gated at peak inflation, and 0.406 mm for the ungated image. Micro-CT images of anaesthetized, free-breathing rats were acquired with a General Electric Healthcare eXplore RS in vivo micro-CT system. Images of the thorax were acquired using the respiratory cycle-based trigger for the respiratory-gated mode. Respiratory gated-images were acquired at inspiration and end expiration, during a period of minimal respiration-induced organ motion. Gated images were acquired with a nominal isotropic voxel spacing of 44 microm in 20-25 min (80 kVp, 113 mAs, 300 ms imaging window per projection). The equivalent ungated acquisitions were 11 min in length. We observed improved definition of the diaphragm boundary and increased conspicuity of small structures within the lungs in the gated images, when compared to the ungated acquisitions. In this work, we have characterized the externally monitored respiratory wave form of free-breathing, anaesthetized rats and correlated the respiration-induced organ motion to the respiratory cycle. We have shown that the respiratory pressure wave form is an excellent surrogate for the radiographic organ motion. This information facilitates the definition of an imaging window at any phase of the breathing cycle. This approach for prospectively gated micro-CT can provide high quality images of anaesthetized free-breathing rodents.

Animals↗

2D-3D registration of coronary angiograms for cardiac procedure planning and guidance.

We present a completely automated 2D-3D registration technique that accurately maps a patient-specific heart model, created from preoperative images, to the patient's orientation in the operating room. This mapping is based on the registration of preoperatively acquired 3D vascular data with intraoperatively acquired angiograms. Registration using both single and dual-plane angiograms is explored using simulated but realistic datasets that were created from clinical images. Heart deformations and cardiac phase mismatches are taken into account in our validation using a digital 4D human heart model. In an ideal situation where the pre- and intraoperative images were acquired at identical time points within the cardiac cycle, the single-plane and the dual-plane registrations resulted in 3D root-mean-square (rms) errors of 1.60 +/- 0.21 and 0.53 +/- 0.08 mm, respectively. When a 10% timing offset was added between the pre- and the intraoperative acquisitions, the single-plane registration approach resulted in inaccurate registrations in the out-of-plane axis, whereas the dual-plane registration exhibited a 98% success rate with a 3D rms error of 1.33 +/- 0.28 mm. When all potential sources of error were included, namely, the anatomical background, timing offset, and typical errors in the vascular tree reconstruction, the dual-plane registration performed at 94% with an accuracy of 2.19 +/- 0.77 mm.

Algorithms↗

Automated image registration of gated cardiac single-photon emission computed tomography and magnetic resonance imaging.

PURPOSE: To develop an automatic registration method for electrocardiogram-gated myocardial perfusion single-photon emission computed tomography (SPECT) and cardiac cine-magnetic resonance imaging (MRI). MATERIALS AND METHODS: Paired myocardial perfusion SPECT (MPS) and MRI from 20 patients were considered. MR images were presegmented by heart localization based on detection of cardiac motion and optimal thresholding. A registration algorithm based on mutual information was subsequently applied to all time frames or a selected subset from both modalities. RESULTS: A preprocessing step significantly improved the accuracy of the registration when compared to automatic registration performed without preprocessing. Errors in translation parameters (T(x), T(y), T(z)) averaged (1.0 +/- 1.5, 1.1 +/- 1.3, 0.9 +/- 0.9) pixels with MRI segmentation and (4.6 +/- 3.2, 3.4 +/- 2.6, 3.0 +/- 3.4) pixels without MRI segmentation. Errors in rotation parameters (R(x), R(y), R(z)) averaged (5.4 +/- 2.9, 3.4 +/- 2.7, 4.5 +/- 3.6) degrees with MRI segmentation and (9.3 +/- 6.1, 4.8 +/- 4.3, 14.6 +/- 12.6) degrees without MRI segmentation. Error was calculated as the absolute difference between the expert manual and the automatic registration transformation. CONCLUSION: Automatic registration of gated MPS and cine MRI is possible with the use of a mutual information-based technique when MR images are presegmented. Cardiac motion can be used to isolate the left ventricle (LV) on the MR images automatically, and subsequently the segmented MR images can be coregistered with gated MPS.

Algorithms↗

Assessment of intra- and interobserver variability of pulmonary vein measurements from CT angiography.

RATIONALE AND OBJECTIVES: Pulmonary vein (PV) stenosis is a common complication after radiofrequency ablation for atrial fibrillation. This study investigated the intra- and interobserver variability and precision of PV ostial measurements from three-dimensional computed tomography angiography. MATERIALS AND METHODS: Four observers measured the maximum and minimum diameters, as well as area, of the four PVs of seven patients who underwent a three-dimensional computed tomography scan before radiofrequency ablation. Each observer performed two sets of measurements. The intra- and interobserver variability of the measurements was calculated using analysis of variance. RESULTS: Intraobserver variability was approximately two times lower than interobserver variability in measurements of diameter and area. The standard error of the measurement (SEM), SEM(intra) and SEM(inter), were lower for the mean diameter than the maximum diameter. The minimum detectable changes in diameters, DeltaD(intra) and DeltaD(inter), and area, DeltaA(intra) and DeltaA(inter), demonstrated the same statistical trend as the corresponding SEM for each of the four veins. Both DeltaD(intra) and DeltaD(inter) and DeltaA(intra) and DeltaA(inter) were smaller than the corresponding lower bounds of the 95% confidence interval for 50% diameter reduction and 75% area reduction. The direct results of DeltaA(intra) and DeltaA(inter) for each of the four veins were consistently less than DeltaA's calculated from the corresponding DeltaD(intra) and DeltaD(inter). CONCLUSION: PV ostial measurements are less variable when made by a single observer than by multiple observers, and mean diameter measurements are more precise than a single, maximum diameter measurement. Both diameter and area measurements are capable of quantifying the mild PV stenosis. Furthermore, area can be measured with greater precision than mean diameter and should be used in PV ostium caliber determination.

Adult↗

Validation of dynamic heart models obtained using non-linear registration for virtual reality training, planning, and guidance of minimally invasive cardiac surgeries.

Current minimally invasive techniques for beating heart surgery are associated with three major limitations: the shortage of realistic and safe training methods, the process of selecting port locations for optimal target coverage from X-rays and angiograms, and the sole use of the endoscope for instrument navigation in a dynamic and confined 3D environment. To supplement the current surgery training, planning and guidance methods, we continue to develop our Virtual Cardiac Surgery Planning environment (VCSP) -- a virtual reality, patient-specific, thoracic cavity model derived from 3D pre-procedural images. In this work, we create and validate dynamic models of the heart and its components. A static model is first generated by segmenting one of the image frames in a given 4D data set. The dynamics of this model are then extracted from the remaining image frames using a non-linear, intensity-based registration algorithm with a choice of six different similarity metrics. The algorithm is validated on an artificial CT image set created using an excised porcine heart, on CT images of canine subjects, and on MR images of human volunteers. We found that with the appropriate choice of similarity metric, our algorithm extracts the motion of the epicardial surface in CT images, or of the myocardium, right atrium, right ventricle, aorta, left atrium, pulmonary arteries, vena cava and epicardial surface in MR images, with a root mean square error in the 1 mm range. These results indicate that our method of modeling the motion of the heart is easily adaptable and sufficiently accurate to meet the requirements for reliable cardiac surgery training, planning, and guidance.

Algorithms↗

Peak velocity determination using fast Fourier velocity encoding with minimal spatial encoding.

For quantitative peak velocity determination, a technique was developed that uses Fourier velocity encoding (FVE) for the fast acquisition of images of velocity with no spatial encoding other than slice selection. The technique produces images of velocity versus temporal frequency. In applications where the quantity of interest is the peak velocity and in-plane spatial localization is not required, high SNR images are produced with reduced sensitivity to errors due to slice thickness and motion. The technique was validated using steady and pulsatile flow in a straight tube, and compared to both phase contrast measurements and numerical models using steady flow in a 50% and a 75% cosinusoidal stenosis phantom. Results show that for slices as large as 2 cm and/or undergoing periodic motion, FVE can accurately measure the peak velocity in cases where a distribution of velocities exist.

Blood Flow Velocity↗