A single-tube nucleic acid extraction, amplification, and detection method using aluminum oxide.

A disposable 0.2-ml polymerase chain reaction (PCR) tube modified with an aluminum oxide membrane (AOM) has been developed for the extraction, amplification, and detection of nucleic acids. To assess the dynamic range of AOM tubes for real-time PCR, quantified herpes simplex virus (HSV) DNA was used to compare AOM tubes to standard PCR tubes. AOM PCR tubes used for amplification and detection of quantified HSV-1 displayed a crossing threshold (C(T)) shift 0.1 cycles greater than PCR tube controls. Experiments with HSV-1-positive cerebrospinal fluid (CSF) examined the extraction, amplification, and detection properties of the AOM tubes compared to the Qiagen DNA blood mini kit. The AOM extraction, amplification, and detection of HSV-1 in CSF displayed differences of less than one C(T) when compared to Qiagen-extracted samples. Experiments testing the AOM method using clinical CSF samples displayed 100% concordance with reported results. AOM tubes have no adverse effects on amplification or fluorescence acquisition by real-time PCR and can be effectively used for the extraction, amplification, and detection of HSV from CSF. The AOM single tube method is a fast, reliable, and reproducible technique for the extraction, amplification, and detection of HSV in CSF.

Aluminum Oxide↗

Genotyping of human platelet antigens 1 to 6 and 15 by high-resolution amplicon melting and conventional hybridization probes.

High-resolution melting techniques are a simple and cost-effective alternative to other closed-tube genotyping methods. Here, we genotyped human platelet antigens (HPAs) 1 to 6 and 15 by high-resolution melting methods that did not require labeled probes. Conventional melting analysis with hybridization probes (HybProbes) was also performed at each locus. HybProbe assays were performed individually, whereas amplicon melting (HPAs 1 to 5 and 16) and unlabeled probe (HPA 6) assays were duplexed when possible. At all loci for each method, both homozygous and heterozygous genotypes were easily identified. We analyzed 100 blinded clinical samples (33 amniotic fluid, 12 cultured amniocytes, and 55 blood samples) for all 7 single-nucleotide polymorphisms (SNPs) by each method. Genotype assignments could be made in 99.0% of the SNPs by high-resolution melting and in 98.7% of the SNPs with HybProbes with an overall genotype concordance of 98.8%. Errors included two sample misidentifications and six incorrect assignments that were all resolved by repeating the analysis. Advantages of high-resolution melting include rapid assay development and execution, no need for modified oligonucleotides, and similar accuracy in genotyping compared with other closed-tube melting methods.

Antigens, Human Platelet↗

HLA-B27 typing: evaluation of an allele-specific PCR melting assay and two flow cytometric antigen assays.

BACKGROUND: Human leukocyte antigen B27 (HLA-B27) is a major histocompatibility complex class 1 molecule that is strongly associated with the disease ankylosing spondylitis. Testing for HLA-B27 is of diagnostic value because 90% of patients with ankylosing spondylitis have the B27 antigen. Two commonly used HLA-B27 flow cytometric assays are commercially available. METHODS: An allele-specific polymerase chain reaction (PCR) melting assay for HLA-B27 was compared with two available antigen assays on 371 clinical samples. The accuracy of the assays was measured by receiver operating characteristic analysis using the PCR method and sequencing as the reference standard. RESULTS: When PCR results were compared with those of the antigen assays, complete concordance was observed except for five discrepant results that were resolved by sequence analysis. Using DNA sequencing as the gold standard, the sensitivity and specificity of PCR were 99.6 and 100.0, those of the best single antigen assay were 98.2 and 97.6, and those of a reflex combination of both antigen assays were 98.8 and 97.6. CONCLUSIONS: The allele-specific PCR melting assay for HLA-B27 genotyping is easy to perform and has better sensitivity and specificity than antigen assays. The performance of the two flow cytometric antigen assays depends on the antibody used and the positive cutoff values assigned.

Alleles↗

Increased sensitivity of bacterial detection in cerebrospinal fluid by fluorescent staining on low-fluorescence membrane filters.

A membrane-filter-based, fluorescent Gram stain method for bacterial detection in cerebrospinal fluid samples was developed and evaluated as a rapid, sensitive alternative to standard Gram stain protocols. A recently developed, modified version of the aluminium oxide membrane Anopore with low-fluorescence optical properties showed superior performance in this application. Other aspects of the fluorescent Gram stain system that were evaluated include membrane filter selection, strategies to reduce fluorescence fading and the effect of patient blood cells on bacterial detection in the fluorescently stained cerebrospinal fluid samples. The combination of the membrane filter's bacteria-concentrating ability and absolute retention along with high-contrast, fluorescent Gram discriminating dyes enabled rapid bacterial detection and Gram discrimination, with a 1-1.5 order of magnitude increase in the bacterial concentration limit of detection.

Bacteriological Techniques↗

Evaluation of the COBAS amplicor HBV monitor assay and comparison with the ultrasensitive HBV hybrid capture 2 assay for quantification of hepatitis B virus DNA.

Performance characteristics of the COBAS Amplicor HBV Monitor test (Roche Diagnostics), which measures hepatitis B virus (HBV) DNA quantitatively, were evaluated and compared with the Ultrasensitive HBV Hybrid Capture 2 (HC2; Digene Corporation) assay. Linearity and within-run precision were assessed for both methods by using eight HBV DNA-positive samples serially diluted to obtain a range of <100 to 500,000 HBV DNA copies/ml and run in triplicate. Agreement between the methods was studied with 100 clinical samples. HC2 assay performance near the limit of detection was investigated through repeat testing of 149 samples with HC2 and testing of 37 samples with HC2 results of <4,700 HBV DNA copies/ml by Amplicor assay and a qualitative PCR assay. The linearity experiment for Amplicor had regression of observed values compared to expected values (y = 1.073x - 0.247; R(2) = 0.993, n = 32; for HC2, y = 0.855x + 0.759, R(2) = 0.729, n = 18). Within-run standard deviation of log HBV DNA copies/ml ranged from 0.003 to 0.348 (Amplicor) and 0.027 to 0.253 (HC2). Agreement assessed by Deming regression was poor [Amplicor = 1.197(HC2) - 0.961; R(2) = 0.799, standard error of the estimate (SEE) = 0.710, n = 94]. Near the lower limit of detection, 32 of 149 repeat HC2 results were <4,700 HBV DNA copies/ml. Of the 37 samples with HC2 results of <4,700 HBV DNA copies/ml, HBV DNA was not detected in 15 samples, while HBV DNA was detected by at least one PCR method in 12 samples. Amplicor is linear from 200 to 200,000 HBV DNA copies/ml with undiluted samples, and this range can be expanded through dilution. Inconsistent HC2 results near the limit of detection justify use of a grey zone.

DNA, Viral↗

Single-tube method for nucleic acid extraction, amplification, purification, and sequencing.

BACKGROUND: The hepatitis C virus (HCV) genotype determines patient prognosis and duration of treatment, but sequencing of the gene is lengthy and labor-intensive. We used a commercially available nucleic acid extraction system to develop a single-tube extraction-to-sequencing (STETS) method for HCV genotyping. METHODS: HCV RNA was purified and amplified in tubes coated with a solid-phase matrix that irreversibly bound nucleic acid during the extraction step. After reverse transcription-PCR, the amplicon was adsorbed to the original extraction matrix for purification and use in the subsequent sequencing reactions. RESULTS: The STETS method generated genotyping-quality sequence for a range of HCV titers from 500 to 6,000,000 IU/mL. If a viral sample was detected during real-time reverse transcription-PCR, it could be sequenced and genotyped. Read lengths >600 bases were observed with the STETS method. Mixed infections were detected and genotyped if at least 15% of the minor species was present. Combining the STETS method with consecutive sequencing provided a means of performing both forward and reverse sequencing in a single tube. CONCLUSIONS: A single-tube nucleic acid extraction-to-sequencing method, which requires less time and labor than conventional methods, generates HCV sequence data that are equivalent to conventional methods and can be used to genotype HCV.

Genotype↗

Hepatitis C genotyping by denaturing high-performance liquid chromatography.

Determination of the hepatitis C virus (HCV) genotype for infected patients increasingly has become accepted as the standard of care. Genotype assignment helps in assessing disease prognosis and assists in establishing the appropriate duration of treatment. The great genetic diversity of HCV, with 11 major genotypes and >70 subtypes, contributes to the technical difficulty of genotype testing. While the "gold standard" for testing is nucleic acid sequencing, a variety of hybridization assays, including the line probe assay, have been developed to provide more rapid and accessible forms of testing. The aim of this study was to determine whether denaturing high-performance liquid chromatography (dHPLC) could be used as a clinical method for distinguishing HCV genotypes 1, 2, 3, and 4. A portion of the 5' untranslated region of the HCV genome was amplified by heminested multiplex reverse transcription PCR. The two amplicons then were analyzed by dHPLC analysis and compared to the genotypes determined by sequence analysis. After 115 specimens were analyzed as standards, 200 masked specimens (specimens whose identity was not known before testing) were analyzed to determine the concordance of the assay. The assay had a concordance of 96% at the genotype level and a concordance of 87% at the subtype level. However, the dHPLC method was not as accurate as other reported methods of HCV genotyping. This is the first time that HCV genotyping has been performed by dHPLC.

5' Untranslated Regions↗

Genotyping hepatitis C virus by heteroduplex mobility analysis using temperature gradient capillary electrophoresis.

The genotype of the infecting hepatitis C virus (HCV) helps determine the patient's prognosis and the duration of treatment. Heteroduplex mobility analysis (HMA) is a rapid, inexpensive method for genotyping of HCV that does not require sequencing. We developed an HMA that uses temperature gradient capillary electrophoresis (TGCE) to differentiate HCV genotypes. A 56-bp region of the HCV 5' untranslated region (UTR) that was conserved within a genotype yet whose sequence differed between genotypes was amplified for HMA-TGCE analysis. HCV amplicons of types 1, 2a, 2b, 3a, 4, and 6a were hybridized in pairs and analyzed by TGCE. Amplicons hybridized to the same subtype yielded one homoduplex peak, while hybridization of different subtypes resulted in heteroduplexes and generated multiple TGCE peaks. Heteroduplexes contain thermodynamically unstable nucleotide mismatches that reduced their TGCE mobilities compared to those of homoduplexes. Three HCV subtypes (subtypes 1a, 3a, and 4) generated unique peak patterns when they were combined with each genotype analyzed and were chosen as the reference genotypes. A blinded study with 200 HCV-infected samples was 97% accurate compared to genotyping by 5' UTR sequence analysis. The majority of discordant results were unexpected sequence variants; however, five of nine sequence variants were correctly genotyped. The assay also detected and correctly genotyped mixed HCV infections. Compared to conventional HMA, TGCE improves the resolution, with better separation of heteroduplexes and homoduplexes. All common HCV genotypes can be detected and differentiated by this HMA-TGCE assay.

Base Sequence↗

Genotyping of single-nucleotide polymorphisms by high-resolution melting of small amplicons.

BACKGROUND: High-resolution melting of PCR amplicons with the DNA dye LCGreen I was recently introduced as a homogeneous, closed-tube method of genotyping that does not require probes or real-time PCR. We adapted this system to genotype single-nucleotide polymorphisms (SNPs) after rapid-cycle PCR (12 min) of small amplicons (</=50 bp). METHODS: Engineered plasmids were used to study all possible SNP base changes. In addition, clinical protocols for factor V (Leiden) 1691G>A, prothrombin 20210G>A, methylenetetrahydrofolate reductase (MTHFR) 1298A>C, hemochromatosis (HFE) 187C>G, and beta-globin (hemoglobin S) 17A>T were developed. LCGreen I was included in the reaction mixture before PCR, and high-resolution melting was obtained within 2 min after amplification. RESULTS: In all cases, heterozygotes were easily identified because heteroduplexes altered the shape of the melting curves. Approximately 84% of human SNPs involve a base exchange between A::T and G::C base pairs, and the homozygotes are easily genotyped by melting temperatures (T(m)s) that differ by 0.8-1.4 degrees C. However, in approximately 16% of SNPs, the bases only switch strands and preserve the base pair, producing very small T(m) differences between homozygotes (<0.4 degrees C). Although most of these cases can be genotyped by T(m), one-fourth (4% of total SNPs) show nearest-neighbor symmetry, and, as predicted, the homozygotes cannot be resolved from each other. In these cases, adding 15% of a known homozygous genotype to unknown samples allows melting curve separation of all three genotypes. This approach was used for the HFE 187C>G protocol, but, as predicted from the sequence changes, was not needed for the other four clinical protocols. CONCLUSIONS: SNP genotyping by high-resolution melting analysis is simple, rapid, and inexpensive, requiring only PCR, a DNA dye, and melting instrumentation. The method is closed-tube, performed without probes or real-time PCR, and can be completed in less than 2 min after completion of PCR.

Factor V↗

Evaluation of electronic microarrays for genotyping factor V, factor II, and MTHFR.

BACKGROUND: Genetic risk factors associated with venous thrombosis include mutations in the factor V (Leiden), factor II (prothrombin), and methylenetetrahydrofolate reductase (MTHFR) genes. We evaluated a method using electronically addressable microarrays for the detection of mutations in these genes that have been associated with vascular disease. METHODS: The NanoChip Molecular Biology Workstation (Nanogen) uses electronic microarrays for mutation detection. Factor V, factor II, and MTHFR genotypes identified in the NanoChip system on 225 samples were compared with genotypes from LightCycler assays (Roche). We determined within- and between-cartridge signal and ratio variation and analyzed the effect of additional mutations at or near the detection area used for the NanoChip assays. RESULTS: Genotypes determined for all three mutations on the NanoChip platform were in complete concordance with LightCycler results. Within-cartridge signal variation as measured by the CV of fluorescence signals was <10% for each allele when present. The within-cartridge CV for heterozygous mutant/wild-type ratios was <8.5%, and between-cartridge CV was <18%. A dilution study showed that results could be obtained in this assay with 6 ng of nucleic acid per PCR, the lowest input tested. The presence of additional sequence variations near the expected mutations can produce equivocal or discrepant results. CONCLUSIONS: Mutation detection using the NanoChip Molecular Biology Workstation was accurate and reproducible for the three assays evaluated.

Electronics↗

Performance characteristics of the COBAS Amplicor Hepatitis C Virus (HCV) Monitor, Version 2.0, International Unit assay and the National Genetics Institute HCV Superquant assay.

The COBAS Amplicor Hepatitis C Virus (HCV) Monitor assay, version 2.0, which reports in international units per milliliter, was compared to the assay reported in copies per milliliter by analyzing dilution series and clinical plasma samples by both methods. In addition, the Amplicor international unit assay was compared to the National Genetics Institute HCV Superquant assay. The dilution series ranged from <100 to 5,000,000 HCV RNA copies/ml and consisted of 32 points, assayed in triplicate in each assay. Thirty clinical samples ranging from 1,000 to 1,000,000 HCV RNA copies/ml were assayed in duplicate. Deming regression analysis comparing the Amplicor HCV RNA international units-per-milliliter and copies-per-milliliter assays was calculated as follows: (Amplicor international units per milliliter) = 1.030(Amplicor copies per milliliter) - 0.392; R(2) = 0.981; n = 28; S(y/x) (standard error of the estimate) = 0.129. The linearity of the Amplicor international units-per-milliliter assay was as follows: observed = 0.886(expected) + 0.437; R(2) = 0.983; n = 30. The linearity of the Superquant assay was as follows: observed= 0.918 (expected) + 0.436; R(2) = 0.986; n = 32. Deming regression analysis comparing the Amplicor and Superquant assays was calculated as follows: Superquant = 1.066(Amplicor) - 0.0197; R(2) = 0.908; S(y/x) = 0.308; n = 28. The Amplicor and Superquant assays were linear through the range of 600 to 600,000 IU of HCV RNA/ml and approximately 300 to 5,000,000 HCV RNA copies/ml, respectively. The narrow range of the Amplicor assay means that some samples will require dilution and retesting for accurate quantification above 600,000 IU of HCV RNA/ml. The Amplicor and Superquant assays agreed well within the range of 600 to 600,000 IU of HCV RNA/ml (approximately 1,000 to approximately 1,000,000 HCV RNA copies/ml). Overall, the Amplicor and Superquant assays agree well, and results obtained in one assay could be expected to compare well with results from the other when reported in copies per milliliter.

Hepacivirus↗