Application of high-performance liquid chromatography with ultraviolet diode array detection and refractive index detection to the determination of class composition and to the analysis of gasoline.

A method of effective application of normal-phase high-performance liquid chromatography (NP-HPLC) with ultraviolet diode array detection (DAD) and refractive index detection (RID) for the determination of class composition of gasoline and its components, i.e. for the determination of content of alkenes, aromatic and saturated hydrocarbons in gasoline meeting modern quality standards, has been developed. An aminopropyl-bonded silica stationary phase was used along with n-hexane or n-heptane as the mobile phase. A DAD signal integrated over the 207-240 nm range was used to determine alkenes. This eliminates the necessity of separating alkenes from saturates, because the latter do not absorb UV radiation above 200 nm. The content of aromatic hydrocarbons is determined by means of a refractive index detector. Calibration was based on hydrocarbon type composition determined by the fluorescent indicator adsorption method, ASTM D1319. The results obtained by the developed method were found to be consistent with those obtained by fluorescent indicator adsorption or by a multidimensional GC method (PIONA) (ASTM D5443). The method can be applied to gasoline meeting recent quality standards, irrespective of refining technology used in the production of gasoline components, including gasoline with various contents of oxygenates. The developed method cannot be used to determine the hydrocarbon type composition of gasoline that contains as a component the so-called pyrocondensate, i.e. the fraction with a boiling point up to 220 degrees C, obtained through thermal pyrolysis of distillation residues of crude oil or coal and, consequently, does not meet the quality standards. The paper includes the procedure for identification of this type of gasoline.

Chromatography, High Pressure Liquid↗

Optimized conditions for hydrocarbon group type analysis of base oils by thin-layer chromatography-flame ionisation detection.

The results of research on the optimization of the thin-layer chromatography-flame ionisation detection for the determination of group composition of natural base oils, including separation of the aromatics into subgroups, are presented. Neutral base oils obtained in several steps of refining from vacuum distillation petroleum fractions are the most difficult to analyze by hydrocarbon group type analysis (HGTA) because of the high content of aliphatic fragments in their molecules. Factors affecting the accuracy and precision of the results were identified. The paper presents the analytical procedure, including two different calibration methods, as well as the results of studies on the reproducibility of HGTA of typical base oils of different viscosity classes under the optimized conditions. The same conditions were found suitable for HGTA of other high-boiling petroleum fractions by TLC with flame ionisation detection. The paper also introduces a new procedure for reproducible determination of polar fractions in base oils utilizing solid-phase extraction columns, and presents a corrected procedure for the determination of saturated compounds and aromatics (mono-, bi- and polycyclic) in base oils by column liquid chromatography.

Calibration↗

Determination of carbon monoxide, methane and carbon dioxide in refinery hydrogen gases and air by gas chromatography.

This paper illustrates a method for determining trace amounts of CO, CH4 and CO2 with the detection limit of 0.15, 0.15 and 0.20 microg/l, respectively, in refinery hydrogen gases or in air. A simple modification of a gas chromatograph equipped with a flame-ionization detector is presented. A Porapak Q column, additionally connected with a short molecular sieve 5A packed column and a catalytic hydrogenation reactor on the Ni catalyst have been applied. The principle of the analytical method proposed is the separation of CO from O2 before the introduction of CO to the methanizer. The analytical procedure and examples of the results obtained have been presented. The modification applied makes it possible to use the GC instrument for other determinations, requiring utilization of the Porapak Q column and the flame-ionization detector. In such cases, the short molecular sieve 5A column and the methanizer can be by-passed.

Carbon Dioxide↗

Determination of the amount of wash amines and ammonium ion in desulfurization products of process gases and results of related studies.

This paper describes a method for the determination of the so-called wash amines and their degradation products, including ammonium ions, in process liquids and wastewater generated during the desulfurization of hydrogen sulfide gas in the process of crude oil refining and also reports the results of related studies. Ion-exchange liquid chromatography employing an inexpensive cation-exchange HPLC column and refractometric detection was used. The results obtained were compared with those obtained by potentiometric titration. Analytical characteristics and a description of the developed procedure are provided. Examples of the results of routine determinations of amines, their degradation products and ammonium ions in process liquids and wastewater are given.

Amines↗