PubMed Health⌕ Search

Biomedical subjects

Marie Restori

Publications and source records attributed to Marie Restori.

2 recordsLinked to original sources

Evidence of genetic heterogeneity in MRCS (microcornea, rod-cone dystrophy, cataract, and posterior staphyloma) syndrome.

PURPOSE: To present the detailed phenotype of a subject with MRCS (microcornea, retinal dystrophy, cataract, and posterior staphyloma) syndrome and to investigate the underlying molecular genetic basis. DESIGN: Interventional case report. METHODS: Clinical examination, electrophysiologic assessment, B-scan ultrasonography, and mutation screening of the gene VMD2. The protocol of the study was approved by the local ethics committee and informed consent was obtained. RESULTS: A 12-year-old boy was identified with bilateral microcornea, rod-cone dystrophy, congenital cataracts, and posterior staphylomata associated with high myopia (MRCS). Mutation screening failed to identify disease-causing sequence variants in VMD2, the gene associated with MRCS syndrome. All previous subjects have had pathogenic VMD2 sequence alterations. CONCLUSIONS: We present a further report of the MRCS syndrome and provide evidence in support of genetic heterogeneity in this phenotype.

Bestrophins↗

Biometry accuracy using zero- and negative-powered intraocular lenses.

PURPOSE: To audit the accuracy of biometry using the SRK/T formula when negative- or zero-powered intraocular lenses (IOLs) are predicted and to compare the results between A-scan, B-scan, and optical methods of biometry. SETTING: Moorfields Eye Hospital, London, United Kingdom. METHODS: This retrospective analysis comprised 78 eyes of 54 patients having cataract surgery with zero- or negative-powered IOLs. Axial lengths were measured with A-scan, B-scan, applanation, or optical methods. Differences between SRK/T-predicted and actual postoperative refraction were analyzed for 75 eyes having cataract surgery. Ocular comorbidity, visual acuity, and biometry readings were also compared. RESULTS: Forty-one percent of 75 patients analyzed were within +/-1.00 diopter (D) of the predicted refraction, although there was a significant tendency toward a hyperopic overcorrection by 1.14 D (95% confidence interval, 0.89-1.39 D). This overcorrection error was consistent across all 3 biometry methods used to estimate axial length and increased with the use of stronger (more negative) IOLs. CONCLUSION: Surgeons should be aware of the tendency for negative-powered lenses to overcorrect and lead to a hyperopic outcome when using the SRK/T biometry formula in highly myopic eyes. A weaker-powered negative IOL is recommended to aim for a more myopic postoperative outcome by about 1.00 to 2.00 D.

Accommodation, Ocular↗