PubMed Health⌕ Search

Biomedical subjects

Marie Ståhlberg

Publications and source records attributed to Marie Ståhlberg.

2 recordsLinked to original sources

Large-surface biosensor technology for enhanced recovery in protein characterization.

A large-surface biosensor technique using surface plasmon resonance (SPR) was tested for protein purification by recovery of a monoclonal antibody against human proinsulin C-peptide. Notably, both reversible attachment/desorption and actual purification of the antibody from a multi-component protein mixture was shown. For initial chip attachment of the peptide ligand, C-peptide was biotinylated and attached to neutravidin on plastic chips with a large gold surface (effective area 26 mm(2)). Antibody binding and desorption was monitored in real-time SPR, and for elution different conditions were employed. Five percent formic acid (in contact with the chip surface for 3 min) in a 60-mul segment between air bubbles was efficient for subsequent analysis. In this manner, protein amounts up to 35 pmoles were recovered in a single capture/elution cycle. Evaluation by SDS-PAGE showed essentially no carryover between fractions in this elution process, and also not with other proteins in the mixture after purification. Compared to existing commercial instruments, this technique gives higher recovery and makes it possible to monitor monitor protein binding/desorption. Recovery of affinity partners at the multi-pmole level is demonstrated for protein purification in SPR approaches.

Adsorption↗

Detection of phosphorylated peptides in proteomic analyses using microfluidic compact disk technology.

A compact disk (CD)-based microfluidic method for selective detection of phosphopeptides by mass spectrometry is described. It combines immobilized metal affinity chromatography (IMAC) and enzymatic dephosphorylation. Phosphoproteins are digested with trypsin and processed on the CD using nanoliter scale IMAC with and without subsequent in situ alkaline phosphatase treatment. This is followed by on-CD matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. Dephosphorylation of the IMAC-enriched peptides allows selective phosphopeptide detection based on the differential mass maps generated (mass shifts of 80 Da or multiples of 80 Da). The CD contains 96 microstructures, each with a 16 nL IMAC microfluidic column. Movement of liquid is controlled by differential spinning of the disk. Up to 48 samples are distributed onto the CD in two equal sets. One set is for phosphopeptide enrichment only, the other for identical phosphopeptide enrichment but combined with in situ dephosphorylation. Peptides are eluted from the columns directly into MALDI target areas, still on the CD, using a solvent containing the MALDI matrix. After crystallization, the CD is inserted into a MALDI mass spectrometer for analysis down to the femtomole level. The average success rate in phosphopeptide detection is over 90%. Applied to noncharacterized samples, the method identified two novel phosphorylation sites, Thr 735 and Ser 737, in the ligand-binding domain of the human mineralocorticoid receptor.

Alkaline Phosphatase↗