PubMed Health⌕ Search

Biomedical subjects

Marie-Helene Fortier

Publications and source records attributed to Marie-Helene Fortier.

2 recordsLinked to original sources

Integrated microfluidic devices with enhanced separation performance: application to phosphoproteome analyses of differentiated cell model systems.

This work reports on the application of a microfluidic device integrating nanoscale LC to nanoelectrospray MS (nano-LC-chip-MS) for the analysis of complex protein digests. Peak profile analyses of more than 700 peptide ions, reproducibly detected across replicate nano-LC-chip-MS runs (n = 5), indicated that the system provided RSD values of 0.24% on retention time, +/- 30 ppm on m/z measurement and +/- 30% variation on intensity over three orders of magnitude. RP adsorbant media with different alkyl chains and particle size packed in both trapping and separation channels were investigated to improve the chromatographic performance of this system. A two-fold improvement in chromatographic peak capacity was achieved using microfluidic devices comprising a 5 mircrom C3 trap with 2.5 microm C18 trap separation channel compared to the traditional 5 microm C18 stationary phase. Enhanced sample selectivity for the identification of phosphopeptides was obtained by combining immobilized metal affinity media prior to peptide separation on the RP microfluidic device. This system was evaluated in the context of differential phosphoproteome analyses to identify changes in signaling events and protein expression of human monocytes following the administration of phorbol ester.

Animals↗

Integrated microfluidic device for mass spectrometry-based proteomics and its application to biomarker discovery programs.

The present investigation describes the analytical performances of a microfluidic device comprising an enrichment column, a reversed-phase separation channel, and a nanoelectrospray emitter embedded altogether in polyimide layers. This configuration minimizes transfer lines and connections and reduces postcolumn peak broadening and dead volumes. This compact and versatile modular nanoLC-chip system was interfaced to both ion trap and time-of-flight mass spectrometers, and its analytical potentials were evaluated in the context of proteomics applications. The figures of merit of this system in terms of peak capacity, reproducibility, sensitivity, and linear dynamic range of peptide detection were determined using tryptic digests of complex protein extracts including albumin- and immunoglobulin-depleted rat plasma samples. The analysis of peak profiles for more than 600 peptide ions reproducibly detected across replicate nanoLC-chip-MS runs (n = 10) indicated that this system provided good reproducibility of retention time and peak intensity with RSD values of less than 0.5 and 9.1%, respectively. Variation in peptide abundance as low as 2-fold changes was identified for spiked tryptic digests present at levels of 2-5 fmol in plasma samples. Sensitivity measurements were performed on dilution series of protein digests spiked into rat plasma samples and provided a detection limit of 1-5 fmol. The modular concept of the microfluidic systems also facilitated the integration of two-dimensional chromatography (strong cation exchange/C18) thereby increasing the sample loading and selectivity of the nanoLC-chip-MS system. The application of this integrated device was evaluated for complex rat plasma samples to compare the number of protein identifications obtained using one- and two-dimensional nanoLC-chip-MS/MS.

Biomarkers↗