PubMed Health⌕ Search

Biomedical subjects

Marilyn E Noz

Publications and source records attributed to Marilyn E Noz.

9 recordsLinked to original sources

Enhancing the utility of prostascint SPECT scans for patient management.

This project investigated reducing the artifact content of In-ill ProstaScint SPECT scans for use in treatment planning and management. Forty-one patients who had undergone CT or MRI scans and simultaneous Tc-99m RBC/In-111 ProstaScint SPECT scans were included. SPECT volume sets, reconstructed using Ordered Set-Expectation Maximum (OS-EM) were compared against those reconstructed with standard Filtered Back projection (FBP). Bladder activity in Tc-99m scans was suppressed within an ellipsoidal volume. Tc-99m voxel values were subtracted from the corresponding In-111 after scaling based on peak activity within the descending aorta. The SPECT volume data sets were merged with the CT or MRI scans before and after processing. Volume merging, based both on visual assessment and statistical evaluation, was not affected. Thus iterative reconstruction together with bladder suppression and blood pool subtraction may improve the interpretation and utility of ProstaScint SPECT scans for patient management.

Aged↗

Appendicitis in children: low-dose CT with a phantom-based simulation technique--initial observations.

PURPOSE: To retrospectively determine the accuracy of low-dose (20-mAs) computed tomography (CT) in the diagnosis of acute appendicitis in children by using a technique that enables the simulation of human CT scans acquired at a lower tube current given the image acquired at a standard dose. MATERIALS AND METHODS: Institutional review board approval was obtained, informed consent was not required, and the study was HIPAA compliant. The authors reviewed 100 standard-dose pediatric abdominal-pelvic CT scans (50 positive and 50 negative scans) obtained in 100 patients and corresponding simulated low-dose (20-mAs) scans. The standard-dose scans were obtained for evaluation in patients suspected of having appendicitis. Scans were reviewed in randomized order by four experienced pediatric radiologists. The patients with positive findings included 21 girls (mean age, 9.2 years) and 29 boys (mean age, 8.4 years). The patients with negative findings included 28 girls (mean age, 9.2 years) and 22 boys (mean age, 8.4 years). Simulation was achieved by adding noise patterns from repeated 20-mAs scans of a pediatric pelvis phantom to the original scans obtained with a standard tube current. Observers recorded their confidence in the diagnosis of appendicitis by using a six-point scale. Dose-related changes were analyzed with generalized estimating equations and the nonparametric sign test. RESULTS: There was a statistically significant (P < .001, sign test) decrease in both sensitivity and accuracy with a lower tube current, from 91.5% with the original tube current to 77% with the lower tube current. A low dose was the only statistically significant (P < .001) risk factor for a false-negative result. The specificity was unchanged at 94% for both the images obtained with the original tube current and the simulated low-dose images. The overall accuracy decreased from 92% with the original dose to 86% with the low dose. CONCLUSION: Preliminary findings indicate that it is feasible to optimize the CT dose used to evaluate appendicitis in children by using phantom-based computer simulations.

Adolescent↗

Procedure for unmasking localization information from ProstaScint scans for prostate radiation therapy treatment planning.

PURPOSE: To demonstrate a method to extract the meaningful biologic information from (111)In-radiolabeled capromab pendetide (ProstaScint) SPECT scans for use in radiation therapy treatment planning by removing that component of the (111)In SPECT images associated with normal structures. METHODS AND MATERIALS: We examined 20 of more than 80 patients who underwent simultaneous (99m)Tc/(111)In SPECT scans, which were subsequently registered to the corresponding CT/MRI scans.A thresholding algorithm was used to identify (99m)Tc uptake associated with blood vessels and CT electron density associated with bone marrow. Corresponding voxels were removed from the (111)In image set. RESULTS: No single threshold value was found to be associated with the (99m)Tc uptake that corresponded to the blood vessels. Intensity values were normalized to a global maximum and, as such, were dependent upon the quantity of (99m)Tc pooled in the bladder. The reduced ProstaScint volume sets were segmented by use of a thresholding feature of the planning system and superimposed on the CT/MRI scans. CONCLUSIONS: ProstaScint images are now closer to becoming a biologically and therapeutically useful and accurate image set. After known sources of normal intensity are stripped away, the remaining areas that demonstrate uptake may be segmented and superimposed on the treatment-planning CT/MRI volume.

Aged↗

A new CT method for measuring cup orientation after total hip arthroplasty: a study of 10 patients.

BACKGROUND: It is difficult to assess the orientation of the acetabular component on routine radiographs. We present a method for determining the spatial orientation of the acetabular component after total hip arthroplasty (THA) using computed tomography. PATIENTS AND METHODS: Two CT-scans, 10 min apart, were obtained from each of 10 patients after THA. Using locally developed software, two independent examiners measured the orientation of the acetabular component in relation to the pelvis. The measurements were repeated after one week. To be independent of the patient position during scanning, the method involved two steps. Firstly, a 3D volumetric image of the pelvis was brought into a standard pelvic orientation, then the orientation of the acetabular component was measured. The orientation of the acetabular component was expressed as operative anteversion and inclination relative to an internal pelvic reference coordinate system. To evaluate precision, we compared measurements across pairs of CT volumes between observers and trials. RESULTS: Mean absolute interobserver angle error was 2.3 degrees for anteversion (range 0-6.6 degrees), and 1.1 degrees for inclination (range 0-4.6 degrees). For interobserver measurements, the precision, defined as one standard deviation, was 2.9 degrees for anteversion, and 1.5 degrees for inclination. A Student's t-test showed that the overall differences between the examiners, trials, and cases were not significant. Data were normally distributed and were not dependent on examiner or trial. INTERPRETATION: We conclude that the implant angles of the acetabular component in relation to the pelvis could be detected repeatedly using CT, independently of patient positioning.

Adult↗

Impact of fusion of indium-111 capromab pendetide volume data sets with those from MRI or CT in patients with recurrent prostate cancer.

OBJECTIVE: Our goal was to evaluate the impact of image fusion on the interpretation of indium-111 Prosta-Scint SPECT scans. MATERIALS AND METHODS: Sixty-seven consecutive patients referred for rising prostate-specific antigen (PSA) levels after initial therapy for primary prostate cancer underwent SPECT 96 hr after infusion of (111)In Prosta-Scint, with simultaneous technetium-99m blood pool imaging. Volume data sets from the SPECT scans were then fused with those from CT and MR images of the pelvis using a 3D landmark-based warping program. The SPECT scans were initially interpreted without benefit of MRI or CT fusion. The fused Prosta-Scint MRI-CT volumes were reevaluated by a nuclear radiologist and an MRI radiologist. Independent reviews before and after fusion were available in these patients. Validation of results after fusion was performed through correlation with PSA changes after radiation therapy. RESULTS: Six patients with sites that could not be evaluated and three without their original Prosta-Scint scanning reports were excluded; thus, 58 patients were studied clinically. Seventy-four of 161 prefusion-positive sites were found to be negative after fusion. These 74 sites subsequently were identified primarily as showing bowel, vessel, or marrow uptake after fusion. In two patients, nodal disease was identified although the review before perfusion indicated none. Twenty-five patients previously thought to have nodal disease appeared to have only local disease after fusion. After local radiation therapy, PSA levels decreased in 12 of 25 patients, increased in five, and were unavailable in eight. CONCLUSION: Although Prosta-Scint SPECT alone can help in the proper management of recurrent prostate cancer, fusion with MRI-CT of the pelvis can improve the specificity of the examination.

Aged↗

Dynamic three-dimensional MR renography for the measurement of single kidney function: initial experience.

A three-dimensional magnetic resonance (MR) renographic method to measure single kidney glomerular filtration rate (GFR) and split renal function was developed that is based on renal signal intensity measurements during 2-3 minutes after intravenous injection of a low dose (2 mL or 0.01 mmol/kg) of gadopentetate dimeglumine. In nine subjects, single kidney MR GFR indices correlated well with technetium 99m (99mTc) diethylenetriaminepentaacetic acid (DTPA) clearance (r = 0.7-0.8) for GFR values of 7-48 mL/min. MR right kidney split renal function values (range, 32%-59%) also correlated well with 99mTc-DTPA radionuclide measurements (r = 0.76); differences between the two methods averaged 0.8% +/- 8. MR renography was performed along with contrast material-enhanced MR imaging of the kidneys and renal arteries and added 8 minutes or less to the total examination time.

Adult↗

Evaluation of a segmentation procedure to delineate organs for use in construction of a radiation therapy planning atlas.

OBJECTIVES: This paper evaluates a semi-automatic segmentation procedure to enhance utilizing atlas based treatment plans. For this application, it is crucial to provide a collection of 'reference' organs, restorable from the atlas so that they closely match those of the current patient. To enable assembling representative organs, we developed a semi-automatic procedure using an active contour method. METHOD: The 3D organ volume was identified by defining contours on individual slices. The initial organ contours were matched to patient volume data sets and then superimposed on them. These starting contours were then adjusted and refined to rapidly find the organ outline of the given patient. Performance was evaluated by contouring organs of different size, shape complexity, and proximity to surrounding structures. We used representative organs defined on CT volumes obtained from 12 patients and compared the resulting outlines to those drawn by a radiologist. RESULTS: A strong correlation was found between the area measures of the delineated liver (r = 0.992), lung (r = 0.996) and spinal cord (r = 0.81), obtained by both segmentation techniques. A paired Student's t-test showed no statistical difference between the two techniques regarding the liver and spinal cord (p > 0.05). CONCLUSION: This method could be used to form 'standard' organs, which would form part of a whole body atlas (WBA) database for radiation treatment plans as well as to match atlas organs to new patient data.

Anatomy, Artistic↗

Stratifying differences on ictal/interictal subtraction SPECT images.

PURPOSE: Subtraction of interictal from ictal single-photon emission computed tomography (SPECT) yields numerous foci that encompass a range of pixel values scattered in the brain. This preliminary study evaluated the significance of this range of values. METHODS: Subtraction images were obtained by registering, normalizing, and subtracting interictal from ictal SPECT for 13 patients. Pixel values of the resulting foci were divided into two groups: group I with 75-100% and group II with 50-75% of the maximal pixel value. Locations of these foci were determined, and concordance with surgical outcomes and scalp and invasive EEG findings was evaluated. RESULTS: In 10 of 13 cases, group I foci showed good concordance with ictal scalp EEG. In addition, group I foci corresponded well to invasive EEG findings in nine of 10 cases. Group I foci had bilateral distributions in seven of 13 cases. In 10 of 13 cases, group I foci corresponded well to regions of surgical resection. Of these 10 patients, nine showed good concordance with scalp EEG, eight showed good invasive EEG concordance, and eight were seizure free after resection. Conversely, group II foci had good concordance with ictal scalp EEG in only five of 13 cases, and invasive EEG findings, in only five of 10 cases. Group II foci had bilateral distributions in 10 of 13 cases. All 10 cases underwent unilateral surgical resections, and all had good surgical outcomes. In six of 13 cases, group II foci showed concordance with surgical sites. Of these six foci, four had poor concordance with scalp EEG, one had poor concordance with invasive EEG, and five had good surgical outcomes. Sensitivity and specificity for seizure localization of Group I foci were 40% and 88% respectively while sensitivity and specificity of Group II foci were 20% and 79% respectively. CONCLUSIONS: Our data demonstrate that foci with 75-100% of maximal pixel values show good concordance with seizure foci, whereas foci of 50-75% may not. Therefore stratifying ictal/interictal differences may improve the specificity and localizing value of subtraction SPECT.

Adolescent↗

Tumor localization and image registration of F-18 FDG coincidence detection scans with computed tomographic scans.

PURPOSE: The aim of this study was to determine the feasibility of registering routine clinical F-18 fluorodeoxyglucose (FDG) coincidence detection (CD) scans with computed tomographic (CT) scans for radiation treatment planning and case management. METHODS: F-18 FDG CD and chest CT scans, performed in 10 randomly selected patients with confirmed or possible adenocarcinoma of the lung, were evaluated. The quality of the matches was verified by comparisons of the center-to-center distance between a region of interest (ROI) manually drawn on the CT slice and warped onto the CD slice with an ROI drawn manually directly on the CD slice. In addition, the overlap between the two ROIs was calculated. RESULTS: All 10 F-18 FDG CD and CT scans were registered with good superimposition of soft tissue density on increased radionuclide activity. The center-to-center distance between the ROIs ranged from 0.29 mm to 8.08 mm, with an average center-to-center distance of 3.89 mm +/- 2.42 mm (0.69 pixels +/- 0.34 pixels). The ROI overlap ranged from 77% to 99%, with an average of 90% +/- 5.6%. CONCLUSIONS: Although the use of F-18 FDG CD shows great promise for the identification of tumors, it shares the same drawbacks as those associated with radiolabeled monoclonal antibody SPECT and ligand-based positron emission tomographic scans in that anatomic markers are limited. This study shows that image registration is feasible and may improve the clinical relevance of CD images.

Adenocarcinoma↗