Preclinical biocompatibility assessment of the EVAHEART ventricular assist device: coating comparison and platelet activation.

Thromboembolism and bleeding remain significant complications of ventricular assist device (VAD) support. Increasing the amount of biocompatibility data collected during preclinical studies can provide additional criteria to evaluate device refinements, while design changes may be implemented before entering clinical use. Twenty bovines were implanted with the EVAHEART centrifugal VAD for durations from 30 to 196 days. Titanium alloy pumps were coated with either diamond-like carbon or 2-methoxyethyloylphosphoryl choline (MPC). Activated platelets and platelet microaggregates were quantified by flow cytometry, including two new assays to quantify bovine platelets expressing CD62P and CD63. Temporally, all assays were low preoperatively, then significantly increased following VAD implantation, before declining to a lower, but still elevated level over 2-3 weeks. MPC-coated VADs produced significantly fewer activated platelets after implant trauma effects diminished. Three animals receiving no postoperative anticoagulation had similar amounts of circulating activated platelets and platelet microaggregates as animals receiving warfarin anticoagulation. Two new methods to quantify bovine activated platelets using antibodies to CD62P and CD63 were characterized and applied. These measures, along with previously described assays, were able to differentiate between two biocompatible coatings and assess effects of anticoagulation regimen in VAD preclinical testing.

Animals↗

Strain hardening of red blood cells by accumulated cyclic supraphysiological stress.

The effect of elevated shear stress upon cellular trauma has been studied for many years, but the effect of long-term cyclic stress trauma on hemorheology has never been explored systematically. This study investigated sublytic trauma of red blood cells (RBCs) caused by repeated exposure to shear stress. A suspension of bovine blood was throttled through a capillary tube (inner diameter 1 mm and length 70 mm) connected to a recirculating flow loop. Samples were withdrawn every 30 min to measure deformability and characteristic time. The deformability of the cell was measured microscopically by observing the shape of the cell during the shear flow. It was found that cyclic shear irreversibly stiffened the cell membrane while the effect was not so much as that of continuous shear. The cell deformability was dramatically reduced by 73% when the stress of 300 Pa was applied for 288 s, while it was 7% under 90 Pa. These results elucidate the need for improved models to predict cellular trauma within the unsteady flow environment of mechanical circulatory assist devices.

Animals↗

A novel hydrodynamic approach to the treatment of coronary artery disease.

AIMS: During severe coronary stenosis, capillary resistance increases. Drag-reducing polymers (DRPs) are blood-soluble macromolecules that reduce vascular resistance, possibly by altering blood hydrodynamics and rheology. Thus, we hypothesized that DRPs would enhance myocardial perfusion distal to a severe coronary stenosis. METHODS AND RESULTS: A flow-limiting left anterior descending (LAD) coronary artery stenosis was created in 12 open chest dogs. Coronary driving pressure, flow, trans-stenotic gradient, and radiolabelled microsphere myocardial perfusion were measured. Myocardial contrast echocardiography was performed and videointensity vs. pulsing interval data in the LAD and left circumflex beds were used to derive red cell velocity and capillary volume. Relative to baseline, the stenosis decreased LAD bed capillary volume (P = 0.019) and red blood cell velocity (P = 0.010). Intravenous DRP (polyethylene oxide, 2.5 ppm) decreased LAD microvascular resistance (P = 0.003) and increased microsphere flow (P = 0.009), capillary volume (P = 0.0006), and red cell velocity (P = 0.007) despite the presence of a severe stenosis. DRP did not alter blood viscosity. CONCLUSIONS: DRPs improve perfusion to myocardium subserved by a flow-limiting coronary stenosis by decreasing microvascular resistance through an increase in capillary volume. Primary modulation of blood hydrodynamics and rheology to reduce microvascular resistance offers a novel approach to the treatment of ischaemic coronary syndromes.

Animals↗

Synthesis of lipopolyhydroxylalkyleneamines for gene delivery.

Various bis(2-hydroxy-3-chloropropyl)alkylamines were synthesized by coupling primary amine with epichlorohydrin and utilized as a monomer to react with ethylenediamine (EDA), N,N'-dimethylethylenediamine (DMEDA), or tetramethylethylenediamine (TMEDA) to generate a series of lipopolyhydroxylalkyleneamines. The number- and weight-average molecular weight (Mn and Mw) and polydispersity index (Mw/Mn) of the lipopolyhydroxylalkyleneamines were dependent on reactant solvent and reaction temperature. The compounds with EDA as backbone have better transfection activity and lower toxicity than those with DMEDA and TMEDA as backbone.

Animals↗

Poly(N-vinylformamide)-A drag-reducing polymer for biomedical applications.

Water-soluble drag-reducing polymers (DRPs) were previously demonstrated to significantly increase blood flow, tissue perfusion, and tissue oxygenation when injected intravenously at nanomolar concentrations in various animal models. Turbulent flow drag-reducing ability was proven to be the most important factor defining the potential of polymers to favorably affect blood circulation. Several DRPs were applied in previous in vivo tests, but the search continues for suitable DRPs for biomedical applications. We demonstrated that poly(N-vinylformamide) (PNVF) with a molecular weight of 4.5 x 10(6) Da significantly reduced resistance to turbulent flow in a pipe and thus presents a DRP. We also found that the PNVF mechanical degradation is much slower than that of the most commonly used DRP, poly(ethylene oxide). PNVF is known to have low toxicity. Furthermore, our pilot in vivo study showed that PNVF had acceptable biocompatibility and hemodynamic effectiveness and thus could be considered as a DRP candidate for potential clinical use.

Amides↗

The PediaFlow pediatric ventricular assist device.

The very limited options available to treat ventricular failure in patients with congenital and acquired heart diseases have motivated the development of a pediatric ventricular assist device (VAD). Our effort involves a consortium consisting of the University of Pittsburgh, Carnegie Mellon University, Children's Hospital of Pittsburgh, World Heart Corporation, and LaunchPoint Technologies, LLC. The overall aim of our program is to develop a highly reliable, biocompatible VAD for chronic support (6 months) of the unique and high-risk population of children between 3 kg and 15 kg (patients from birth to 2 years of age). The innovative pediatric VAD we are developing (PediaFlow) is based on a miniature mixed-flow turbodynamic pump featuring magnetic levitation, with the design goal being to assure minimal blood trauma and risk of thrombosis. This article discusses the limitations of current pediatric cardiac assist treatment options and the work to date by our consortium toward the development of a pediatric VAD.

Biocompatible Materials↗

Towards the development of a pediatric ventricular assist device.

The very limited options available to treat ventricular failure in children with congenital and acquired heart diseases have motivated the development of a pediatric ventricular assist device at the University of Pittsburgh (UoP) and University of Pittsburgh Medical Center (UPMC). Our effort involves a consortium consisting of UoP, Children's Hospital of Pittsburgh (CHP), Carnegie Mellon University, World Heart Corporation, and LaunchPoint Technologies, Inc. The overall aim of our program is to develop a highly reliable, biocompatible ventricular assist device (VAD) for chronic support (6 months) of the unique and high-risk population of children between 3 and 15 kg (patients from birth to 2 years of age). The innovative pediatric ventricular assist device we are developing is based on a miniature mixed flow turbodynamic pump featuring magnetic levitation, to assure minimal blood trauma and risk of thrombosis. This review article discusses the limitations of current pediatric cardiac assist treatment options and the work to date by our consortium toward the development of a pediatric VAD.

Biocompatible Materials↗

Microscopic investigation of erythrocyte deformation dynamics.

The understanding of erythrocyte deformation under conditions of high shear stress and short exposure time is central to the study of hemorheology and hemolysis within prosthetic blood contacting devices. A combined computational and experimental microscopic study was conducted to investigate the erythrocyte deformation and its relation to transient stress fields. A microfluidic channel system with small channels fabricated using polydimethylsiloxane on the order of 100 mum was designed to generate transient stress fields through which the erythrocytes were forced to flow. The shear stress fields were analyzed by three-dimensional computational fluid dynamics. Microscopic images of deforming erythrocytes were experimentally recorded to obtain the changes in cell morphology over a wide range of fluid dynamic stresses. The erythrocyte elongation index (EI) increased from 0 to 0.54 with increasing shear stress up to 123 Pa. In this shear stress range, erythrocytes behaved like fluid droplets, and deformed and flowed following the surrounding fluid. Cells exposed to shear stress beyond 123 Pa (up to 5170 Pa) did not exhibit additional elongation beyond EI=0.54. Two-stage deformation of erythrocytes in response to shear stress was observed: an initial linear elongation with increasing shear stress and a plateau beyond a critical shear stress.

Animals↗

Survival in a rat model of lethal hemorrhagic shock is prolonged following resuscitation with a small volume of a solution containing a drag-reducing polymer derived from aloe vera.

Drag-reducing polymers (DRP) increase tissue perfusion at constant driving pressure. We sought to evaluate the effects of small-volume resuscitation with a solution containing a DRP in a rat model of hemorrhage. Anesthetized rats were hemorrhaged at a constant rate over 25 min. In protocol A, total blood loss was 2.45 mL/100 g, whereas in protocol B, total blood loss was 3.15 mL/100 g. Five minutes after hemorrhage, the animals were resuscitated with 7 mL/kg of either normal saline (NS) or NS containing 50 microg/mL of an aloe vera-derived DRP. In protocol B, a third group (CON) was not resuscitated. Whole-body O2 consumption (Vo2) and CO2 production (Vco2) were measured using indirect calorimetry. In protocol A, 5/10 rats in the NS group and 8/10 rats in the DRP group survived for 4 h (P = 0.14). Mean arterial pressure was higher in the DRP-treated group than in the NS-treated group 45 min after resuscitation (89 +/- 8 vs. 68 +/- 5 mmHg, respectively; P < 0.05). In protocol B, survival rates over 2 h in the DRP, NS, and CON groups were 5/15, 1/14, and 0/7, respectively (P < 0.05). Compared with NS-treated rats, those resuscitated with DRP achieved a higher peak Vo2 (9.0 +/- 1.0 vs. 6,3+/- 1.0 mL/kg/min) and Vco2 (9.0 +/- 1.1 vs. 6.0 +/- 1.0 mL/kg/min) after resuscitation. We conclude that resuscitation with a small volume of DRP prolongs survival in rats with lethal hemorrhagic shock.

Aloe↗

Tissue hypoxia activates JNK in the liver during hemorrhagic shock.

The earliest signaling pathways responsible for initiating the systemic response to hemorrhagic shock (HS) remain poorly characterized. We have investigated the involvement of the mitogen-activated protein (MAP) kinase C-JUN N-terminal kinase (JNK) and its activation in the liver as an early response to tissue hypoxia soon after the initiation of hemorrhage. In the present studies, hemorrhage of mice to 25 mmHg for 30 min resulted in a significant (2.1-fold) increase in JNK phosphorylation within the liver. Results were similar in rats hemorrhaged to 40 mmHg for 1 h. Hypoxia alone, replicated by warm isolated hepatic ischemia in vivo or hepatocytes cultured under 1% oxygen, also resulted in JNK phosphorylation. Finally, preservation of tissue perfusion and oxygenation by pretreatment with a blood-soluble drag-reducing polymer (DRP) in the rat HS model prevented phosphorylation of JNK in the liver. These results identify tissue hypoxia as a key factor in activating early signaling events in the liver following hemorrhage, as measured by JNK phosphorylation.

Animals↗

Blood soluble drag-reducing polymers prevent lethality from hemorrhagic shock in acute animal experiments.

Over the past several decades, blood-soluble drag reducing polymers (DRPs) have been shown to significantly enhance hemodynamics in various animal models when added to blood at nanomolar concentrations. In the present study, the effects of the DRPs on blood circulation were tested in anesthetized rats exposed to acute hemorrhagic shock. The animals were acutely resuscitated either with a 2.5% dextran solution (Control) or using the same solution containing 0.0005% or 5 parts per million (ppm) concentration of one of two blood soluble DRPs: high molecular weight (MW=3500 kDa) polyethylene glycol (PEG-3500) or a DRP extracted from Aloe vera (AVP). An additional group of animals was resuscitated with 0.0075% (75 ppm) polyethylene glycol of molecular weight of 200 kDa (PEG-200), which possesses no drag-reducing ability. All of the animals were observed for two hours following the initiation of fluid resuscitation or until they expired. We found that infusion of the DRP solutions significantly improved tissue perfusion, tissue oxygenation, and two-hour survival rate, the latter from 19% (Control) and 14% (PEG-200) to 100% (AVP) and 100% (PEG-3500). Furthermore, the Control and PEG-200 animals that survived required three times more fluid to maintain their blood pressure than the AVP and PEG-3500 animals. Several hypotheses regarding the mechanisms underlying these observed beneficial hemodynamic effects of DRPs are discussed. Our findings suggest that the drag-reducing polymers warrant further investigation as a potential clinical treatment for hemorrhagic shock and possibly other microcirculatory disorders.

Acute Disease↗

Rheologic dissimilarities in female and male blood: potential link to development of cardiovascular diseases.

Oxygen Delivery Index (ODI) was introduced as the ratio of red blood cell concentration (hematocrit) to blood viscosity. The ODI can be considered an indirect characterization of oxygen transport to organs and tissues. ODI was obtained for 98 healthy donors (47 pre-menopausal women and 51 age-matched men). In this population ODI levels were found to be significantly lower (p < 0.001) in male blood (7.7 +/- 0.3 vs. 8.4 +/- 0.5 in female blood). Average ODI obtained for 15 cardiac patients (all males) was found to be significantly lower than that for healthy men. In red blood cell suspensions with the same hematocrit, ODI was found to decrease when plasma viscosity was increased via an increase in protein concentration. Additionally, it was found that ODI measured for samples of blood over a wide hematocrit range, obtained by dilution with autologous plasma, possessed the highest values at the hematocrit levels 30 to 40%. The decreased oxygen transport might contribute to the significantly higher morbidity and mortality from cardiovascular diseases for men compared to pre-menopausal women. ODI may be a useful parameter for evaluation of risk of development of cardiovascular disorders.

Adult↗

Smooth muscle cell hypertrophy of renal cortex arteries with chronic continuous flow left ventricular assist.

BACKGROUND: Pathophysiology of long-term continuous flow left ventricular assist is not well described. With many of these devices becoming available, it is important to examine for possible pathologic effects. In this study we examined the relationship between diminished pulsatility and pathologic changes in renal cortical arteries. METHODS: Twenty-nine calves were implanted with various continuous flow left ventricular assist systems in a left ventricle-descending thoracic aorta bypass configuration. Pulsatility was quantified by pulse pressure and pulsatility index. Pathologic changes of the renal cortex arteries were described and evaluated by medial thickness, medial/vascular cross-sectional area ratio, and smooth muscle cell count, to quantify hypertrophy or hyperplasia. Seven calves, which underwent a sham-implant, were used as controls. RESULTS: Systolic arterial pressure, pulse pressure, and pulsatility index were significantly lower and diastolic pressure was significantly higher than before implant in pump-implanted animals. Twenty-three of 29 pumpimplanted calves (79.3%) had medial smooth muscle cell hypertrophy in renal cortex arteries, whereas none of sham-implanted calves had any abnormal lesions. When the pump-implanted calves were grouped according to the presence of smooth muscle cell hypertrophy, there was a clear trend toward lower pump flow rate in calves with lesions. Renal function was within the normal range in all calves. CONCLUSIONS: There appears to be a relationship between smooth muscle cell hypertrophy in renal cortex arteries and continuous flow left ventricular assist. Furthermore, although the pathologic changes are likely multifactorial, these lesions appear to be related to lower pump assist rates.

Animals↗

Distal thoracic aorta hemodynamics during exercise with continuous flow left ventricular assist system.

OBJECTIVES: Continuous flow left ventricular assist systems (LVAS) are being discussed as a destination therapy. LVAS patients will have expanded activity of daily life, including exercise. In this study, we analyzed the effects of exercise on blood flow in the distal thoracic aorta of LVAD implanted animals. METHODS: Five calves with a continuous flow LVAS exercised on treadmill at two different pump flow rates (PFR), 60-80% (high PFR) and 25-30% (low PFR) of pulmonary artery flow rate. Pump, pulmonary artery and descending thoracic aorta flow waves were recorded before, during and after exercise. Systolic and diastolic flow volume in each cardiac cycle in pump and descending thoracic aorta flow was calculated. RESULTS: (1) Average flow rates - Pulmonary artery and descending thoracic aorta flow rates increased with heart rate during exercise and there was no difference between groups. (2) Pump flow wave - Pump regurgitation increased temporally during exercise at both PFRs, but sustained incidences of regurgitation after exercise were only observed at low PFR. Systolic and diastolic pump flow volume decreased during exercise at both PFRs, but systolic volume increased and diastolic volume decreased significantly after exercise at low PFR. (3) Descending thoracic aorta flow wave - At high PFR, systolic volume of descending thoracic aorta increased but diastolic flow volume decreased during exercise. At low PFR, both systolic and diastolic volume of the descending thoracic aorta decreased during exercise, but systolic volume increased and diastolic volume decreased after exercise. Systolic volume of the descending thoracic aorta in low PFR was significantly greater and diastolic volume was less than those in high PFR during and after exercise. CONCLUSION: Exercise temporarily increases pump regurgitation with continuous flow LVAS support. Average flow rate of the descending thoracic aorta was maintained by compensation from increased heart rate, although the diastolic flow of the descending thoracic aorta decreased after exercise at the lower pump flow rate. Further study will be needed to evaluate whether or not this flow decrease causes hemodynamic and/or an oxygen delivery mismatch to peripheral tissue.

Animals↗

In vivo evaluation of a MPC polymer coated continuous flow left ventricular assist system.

The aim of this study was the evaluation of the thrombogenicity and the biocompatibility of the SunMedical EVAHEART left ventricular assist system (LVAS) coated with 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer compared to a diamond-like carbon (DLC) coating. Four calves were implanted with the MPC polymer-coated LVAS. Eight calves were implanted with DLC coated LVAS. The thrombogenicity and biocompatibility of the pumps were evaluated. At explant, 60.0 +/- 37.2% (5-85%) of the pump surface area was still coated with MPC polymer after the duration of 45.0 +/- 32.0 days. In 1 out of 4 MPC and 2 out of 8 DLC coated pumps, there was a very small amount of thrombus around the seal ring; otherwise the blood contacting surfaces were free of thrombus. Major organs were normal except for a few lesions in kidneys from both groups. The MPC polymer coated EVAHEART LVAS seems to have low thrombogenicity and high biocompatibility similar to the DLC coated system. The current study demonstrated that the MPC polymer coating shows great promise for being used as an antithrombogenic substrate for the LVAS due to its ease of application, significant cost benefit, and reduction in anticoagulation therapy in acute postoperative period.

Animals↗

In vitro evaluation of hemolysis and sublethal blood trauma in a novel subcutaneous vascular access system for hemodialysis.

Hemodialysis requires reliable frequent access to the patients' vasculature, with blood flow rates of > 300 ml/min. Currently in the U.S. market, there are three types of hemodialysis access systems: the native arteriovenous fistula, generally using 15G needles; the synthetic arteriovenous (AV) graft, also generally using 15G needles; and the percutaneous catheter. Some of the problems with current vascular access technologies include insufficient blood flow, blood trauma, thrombosis, infection, cardiac load, and venous stenosis. The LifeSite System (Vasca, Inc.) represents an alternative for vascular access, and consists of a subcutaneous valve and 12F cannula accessed by a standard 14G needle. The LifeSite valve is implanted in the upper torso with the cannula generally entering the right internal jugular vein. The purpose of this study was to compare the LifeSite System with two known vascular access systems: the 10F dialysis catheter (Tesio-Cath, MedComp) and the 15G A.V. Fistula Needle Set (JMS Co., Ltd.) with regard to blood damage produced by these devices in use. Mechanical hemolysis and sublethal blood trauma were evaluated by means of in vitro blood pumping through a circulating loop incorporating a hemodialysis vascular access system. Sublethal blood damage was examined by using a hemorheologic assay that included parameters such as erythrocyte mechanical fragility, plasma total protein and fibrinogen concentrations, and blood viscosity. The tests demonstrated that, at both studied flow rates of 300 ml/min and 450 ml/min, the LifeSite produced lower hemolysis and less sublethal damage to blood than either the Tesio-Cath catheter or the A.V. Fistula Needle Set.

Animals↗

Effects of continuous flow left ventricular assist device support on skin tissue microcirculation and aortic hemodynamics.

Continuous flow ventricular assist devices (CFVADs) are thought to be the next generation of circulatory assist devices. With many now in various stages of development or clinical trial, it is important that the physiologic aspects of these pumps be critically analyzed. In this study, 15 calves were divided into two groups. One group received a CFVAD, and the other a sham implant. Two additional animals were used in an acute study to examine aortic blood flow patterns from a CFVAD. Tissue perfusion was measured on all animals before surgery and then weekly thereafter. Before surgery, there was no difference in hemodynamics or tissue perfusion between studied animals. Postoperatively, CFVAD animals had statistically significant increased diastolic pressure. Significantly decreased pulse pressure, pulse index, and tissue perfusion were also observed in CFVAD animals. Results from the flow pattern studies suggested that at moderate levels of pump support (40-75%), the amount of blood flow distal to the outflow graft anastomosis decreased approximately 25% because of increased regurgitant blood flow in the aorta. These results suggest that the diminished tissue perfusion is likely due to changes in aortic hemodynamics and provide some insight into the distribution of flow from CFVADs.

Animals↗