PubMed Health⌕ Search

Biomedical subjects

Marine Soret

Publications and source records attributed to Marine Soret.

3 recordsLinked to original sources

Quantification in simultaneous (99m)Tc/(123)I brain SPECT using generalized spectral factor analysis: a Monte Carlo study.

In SPECT, simultaneous (99m)Tc/(123)I acquisitions allow comparison of the distribution of two radiotracers in the same physiological state, without any image misregistration, but images can be severely distorted due to cross-talk between the two isotopes. We propose a generalized spectral factor analysis (GSFA) method for solving the cross-talk issue in simultaneous (99m)Tc/(123)I SPECT. In GSFA, the energy spectrum of the photons in any pixel is expressed as a linear combination of five common spectra: (99m)Tc and (123)I photopeaks and three scatter spectra. These basis spectra are estimated from a factor analysis of all spectra using physical priors (e.g. Klein-Nishina distributions). GSFA was evaluated on (99m)Tc/(123)I Monte Carlo simulated data and compared to images obtained using recommended spectral windows (WIN) and to the gold standard (GS) images (scatter-free, cross-talk-free and noise-free). Using GSFA, activity concentration differed by less than 9% compared to GS values against differences from -23% to 110% with WIN in the (123)I and (99m)Tc images respectively. Using GSFA, simultaneous (99m)Tc/(123)I imaging can yield images of similar quantitative accuracy as when using sequential and scatter-free (99m)Tc/(123)I imaging in brain SPECT.

Algorithms↗

Partial volume effect correction in SPECT for striatal uptake measurements in patients with neurodegenerative diseases: impact upon patient classification.

PURPOSE: In single-photon emission computed tomography (SPECT) of the dopaminergic system, measurements of striatal uptake are useful for diagnosis and patient follow-up but are strongly biased by the partial volume effect (PVE). We studied whether PVE correction might improve patient classification based on binding potential (BP) measurements. METHODS: Patients with a probable diagnosis of dementia with Lewy bodies (DLB, 10 patients) or Alzheimer's disease (AD, 13 patients) were studied by( 123)I-FP-CIT SPECT. SPECT images were reconstructed with and without PVE correction. Each patient SPECT scan was also simulated to obtain SPECT data whose characteristics were fully known. In addition, 17 SPECT scans were simulated with striatal uptake values mimicking pre-symptomatic cases of DLB. RESULTS: Without PVE correction, mean putamen BP values were 2.9+/-0.4 and 0.9+/-0.2 for AD and DLB patients respectively, while with PVE correction, they were 8.6+/-1.5 and 1.9+/-0.5 respectively. All patients were properly identified as having AD or DLB when considering mean putamen BP measured on their real or simulated SPECT scan, with and without PVE correction. All 30 simulations mimicking pre-symptomatic DLB and AD patients were accurately classified with PVE correction, but without PVE correction 15 mean putamen BP values were in a range where AD and DLB could not be distinguished. CONCLUSION: We conclude that putamen BP values measured without PVE correction can be used to differentiate probable DLB and AD due to the already severe reduction in dopamine transporter levels. PVE correction appeared useful for accurate differential diagnosis between AD and pre-symptomatic DLB.

Aged↗

Quantitative accuracy of dopaminergic neurotransmission imaging with (123)I SPECT.

UNLABELLED: 123I-Labeled radiotracers are suitable for in vivo imaging of the dopaminergic system by SPECT. However, precise measurement of striatal uptake is limited by scatter, attenuation, and the finite spatial resolution of the camera. We studied the quantitative accuracy that can be achieved with (123)I SPECT of the dopaminergic neurotransmission system. METHODS: Using a Monte Carlo simulation and brain phantom experiments, we studied the biases in brain and striatal absolute uptake estimates and in binding potential (BP) values for different processing schemes with corrections for attenuation, scatter, and the partial-volume effect. RESULTS: Without any correction, brain activity was underestimated by at least 65%, and absolute striatal activity measured in regions corresponding to the anatomic contours of the striata was underestimated by about 90%. With scatter and attenuation corrections only, estimated brain activity was accurate within 10%; however, striatal activity remained underestimated by about 50%, and BP values were underestimated by more than 50%. When combined with attenuation and scatter corrections, anatomically guided partial-volume effect correction (PVC) reduced the biases in striatal activity estimates and in BP values to about 10%. PVC reliability was affected by errors in registering SPECT with anatomic images, in segmenting anatomic images, and in estimating the spatial resolution. With registration errors of 1 voxel (2.1 x 2.1 x 3.6 mm(3)) in all directions and of 15 degrees around the axial direction, PVC still improved the accuracy of striatal activity and BP estimates compared with scatter and attenuation corrections alone, the errors being within 25%. A 50% overestimation of the striatal volume yielded an approximate 30% change in striatal activity estimates with respect to no overestimation but still provided striatal activity estimates that were more accurate than those obtained without PVC (average errors +/- 1 SD were -22.5% +/- 1.0% with PVC and -49.0% +/- 5.5% without PVC). A 2-mm error in the spatial resolution estimate changed the striatal activity and BP estimates by no more than 10%. CONCLUSION: Accurate estimates of striatal uptake and BP in (123)I brain SPECT are feasible with PVC, even with small errors in registering SPECT with anatomic data or in segmenting the striata.

Brain↗