PubMed Health⌕ Search

Biomedical subjects

Mark Arnold

Publications and source records attributed to Mark Arnold.

8 recordsLinked to original sources

Liquid-liquid extraction of strongly protein bound BMS-299897 from human plasma and cerebrospinal fluid, followed by high-performance liquid chromatography/tandem mass spectrometry.

BMS-299897 is a gamma-secretase inhibitor that is being developed for the treatment of Alzheimer's disease. Liquid-liquid extraction (LLE), chromatographic/tandem mass spectrometry (LC/MS/MS) methods have been developed and validated for the quantitation of BMS-299897 in human plasma and cerebrospinal fluid (CSF). Both methods utilized (13)C6-BMS-299897, the stable label isotope analog, as the internal standard. For the human plasma extraction method, two incubation steps were required after the addition of 5 mM ammonium acetate and the internal standard in acetonitrile to release the analyte bound to proteins prior to LLE with toluene. For the human CSF extraction method, after the addition of 0.5 N HCl and the internal standard, CSF samples were extracted with toluene and no incubation was required. The organic layers obtained from both extraction methods were removed and evaporated to dryness. The residues were reconstituted and injected into the LC/MS/MS system. Chromatographic separation was achieved isocratically on a MetaChem C18 Hypersil BDS column (2.0 mm x 50 mm, 3 microm). The mobile phase contained 10 mM ammonium acetate pH 5 and acetonitrile. Detection was by negative ion electrospray tandem mass spectrometry. The standard curves ranged from 1 to 1000 ng/ml for human plasma and 0.25-100 ng/ml for human CSF. Both standard curves were fitted to a 1/x weighted quadratic regression model. For both methods, the intra-assay precision was within 8.2% CV, the inter-assay precision was within 5.4% CV, and assay accuracy was within +/-7.4% of the nominal values. The validation and sample analysis results demonstrated that both methods had acceptable precision and accuracy across the calibration ranges.

Analysis of Variance↗

Increased productivity in quantitative bioanalysis using a monolithic column coupled with high-flow direct-injection liquid chromatography/tandem mass spectrometry.

The feasibility of using a monolithic column as the analytical column in conjunction with high-flow direct-injection liquid chromatography/tandem mass spectrometry (LC/MS/MS) to increase productivity for quantitative bioanalysis has been investigated using plasma samples containing a drug and its epimer metabolite. Since the chosen drug and its epimer metabolite have the same selected reaction monitoring (SRM) transitions, chromatographic baseline separation of these two compounds was required. The results obtained from this monolithic column system were directly compared with the results obtained from a previously validated assay using a conventional C18 column as the analytical column. Both systems have the same sample preparation, mobile phases and MS conditions. The eluting flow rate for the monolithic column system was 3.2 mL/min (with 4:1 splitting) and for the C18 column system was 1.2 mL/min (with 3:1 splitting). The monolithic column system had a run time of 5 min and the conventional C18 column system had a run time of 10 min. The methods on the two systems were found to be equivalent in terms of accuracy, precision, sensitivity and chromatographic separation. Without sacrificing the chromatographic separation, sensitivity, accuracy and precision of the method, the reduced run time of the monolithic column method increased the sample throughput by a factor of two.

Animals↗

Screening for the Lynch syndrome (hereditary nonpolyposis colorectal cancer).

BACKGROUND: Germ-line mutations in the mismatch-repair genes MLH1, MSH2, MSH6, and PMS2 lead to the development of the Lynch syndrome (hereditary nonpolyposis colorectal cancer), conferring a strong susceptibility to cancer. We assessed the frequency of such mutations in patients with colorectal cancer and examined strategies for molecular screening to identify patients with the syndrome. METHODS: Patients with a new diagnosis of colorectal adenocarcinoma at the major hospitals in metropolitan Columbus, Ohio, were eligible for the study. Genotyping of the tumor for microsatellite instability was the primary screening method. Among patients whose screening results were positive for microsatellite instability, we searched for germ-line mutations in the MLH1, MSH2, MSH6, and PMS2 genes with the use of immunohistochemical staining for mismatch-repair proteins, genomic sequencing, and deletion studies. Family members of carriers of the mutations were counseled, and those found to be at risk were offered mutation testing. RESULTS: Of 1066 patients enrolled in the study, 208 (19.5 percent) had microsatellite instability, and 23 of these patients had a mutation causing the Lynch syndrome (2.2 percent). Among the 23 probands with the Lynch syndrome, 10 were more than 50 years of age and 5 did not meet the Amsterdam criteria or the Bethesda guidelines for the diagnosis of hereditary nonpolyposis colorectal cancer (including the use of age and family history to identify patients at high risk for the Lynch syndrome). Genotyping for microsatellite instability alone and immunohistochemical analysis alone each failed to identify two probands. In the families of 21 of the probands, 117 persons at risk were tested, and of these, 52 had Lynch syndrome mutations and 65 did not. CONCLUSIONS: Routine molecular screening of patients with colorectal adenocarcinoma for the Lynch syndrome identified mutations in patients and their family members that otherwise would not have been detected. These data suggest that the effectiveness of screening with immunohistochemical analysis of the mismatch-repair proteins would be similar to that of the more complex strategy of genotyping for microsatellite instability.

Adaptor Proteins, Signal Transducing↗

Surgical management of colorectal cancer in the laparoscopic era: a review of prospective randomized trials.

The benefits of laparoscopy in benign diseases are quite clear. Patients generally can expect smaller incisions, less narcotic usage, quicker return of bowel function, and shorter hospitalizations. The benefits of laparoscopy in oncologic surgery are less clear, and laparoscopic oncology surgery has many critics. Early reports of long surgical times, high operating room costs, and alarming rates of port-site recurrences after laparoscopic colectomy for colorectal cancer all but stopped this less-invasive approach outside the confines of clinical protocols. As the results of larger retrospective studies began to refute these earlier detrimental claims, prospective randomized trials began to take a foothold. In this article, we review these randomized trials with particular attention to the perioperative effects of laparoscopic colectomy and the short-term oncologic outcomes.

Adenocarcinoma↗

Determination of a neuroprotective agent (S)-(+)-BMS-204352 in human, rat and dog plasma by enantioselective liquid chromatography-tandem mass spectrometry.

A sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC/ESI/MS/MS) for the enantioselective determination of (S)-(+)-BMS-204352, a potent and specific maxi-K channel opener, in human, rat and dog plasma was developed. (S)-(+)-BMS-204352, its enantiomer (R)-(--)-BMS-204353 and the internal standard (13C-deuterated racemate of (S)-(+)-BMS-204352) were extracted from plasma using toluene. Chromatographic separation for the enantiomers was achieved on a Chiralcel OD-H analytical column with a run time of 8 min. An aqueous mobile phase modifier was added post column to enhance the mass spectrometer sensitivity. ESI mass spectra were acquired in the negative mode with selected reaction monitoring. The limit of quantitation (LLOQ) is 0.10 ng/mL for human plasma assay. Samples from a clinical study and two animal studies were processed using these procedures. Based on the in vivo data, lack of inversion of (S)-(+)-BMS-204352 to (R)-(--)-BMS-204353 was demonstrated in human, rat and dog after administration of the drug. A sensitive non-enantioselective LC/ESI/MS/MS assay has also been developed for (S)-(+)-BMS-204352 which uses a similar extraction procedure with a C18 column with a limit of quantitation at 0.05 ng/mL. Human study samples were analyzed by both methods and the correlation coefficient between both sets of data is greater than 0.99.

Animals↗

Modelling studies on bovine spongiform encephalopathy occurrence to assist in the review of the over 30 months rule in Great Britain.

The objective of this study was to contribute to a risk assessment to review the over 30 months (OTM) scheme in cattle, whereby all cattle aged over 30 months slaughtered in the UK are removed from the human food chain. We use back-calculation methods to estimate the impact of changes to the OTM rule, by using passive and active surveillance data collected between 1 July 2001 and 30 June 2002. There are two types of change considered: increasing the age limit and allowing animals born after a certain date into the food chain. Results indicate that under the OTM rule less than 1 animal in the last 12 months of the incubation period would enter the food chain in 2003. The birth date changes considered and small changes to the upper age limit would increase this number by a relatively small amount.

Age Factors↗

Quantitative determination of pioglitazone in human serum by direct-injection high-performance liquid chromatography mass spectrometry and its application to a bioequivalence study.

A simple, high throughput, direct-injection high-performance liquid chromatography tandem mass spectrometry method (LC/MS/MS) has been developed and validated for the quantitation of pioglitazone in human serum. After mixing the internal standard with a sample, a 10 microl portion of the mixture was directly injected into a high-flow LC/MS/MS system, which included an extraction column, an analytical column and a six-port switching valve. The on-line extraction was achieved on an Oasis HLB column (1 mm x 50 mm, 30 microm) with a 100% aqueous loading mobile phase containing 5 mM ammonium acetate (pH 4.0) at a flow rate of 4 ml/min. The extracted analyte was eluted by a mobile phase which contained 5 mM ammonium acetate and acetonitrile. The analytical column was a Luna C18 column (4.6 mm x 50 mm, 5 microm). Detection was achieved by positive ion electrospray tandem mass spectrometry. The lower limit of quantitation of the method was 9 ng/ml. The standard curve, which ranged from 9 to 1350 ng/ml, was fitted by a weighted (1/x2) quadratic regression model. The validation results demonstrated that this method had satisfactory precision and accuracy across the calibration range. There was no evidence of instability of the analyte in human serum following three freeze-thaw cycles, and samples could be stored for at least 2 weeks at -30 degrees C. This method was used to analyze pioglitazone concentrations in human serum samples from a bioequivalence study of a blinded Actos formulation (encapsulated 15 mg tablet) and an Actos 15 mg tablet. The blinded formulation was shown to be bioequivalent to an Actos 15 mg tablet.

Calibration↗

Disposition of radiolabeled BMS-204352 in rats and dogs.

BMS-204352, a maxi-K channel opener, is currently under development for the treatment of stroke. The objective of this study was to determine the pharmacokinetics, mass balance and absolute oral bioavailability of [(14)C]-BMS-204352 in rats and dogs. [(14)C]-BMS-204352 was administered, to rats (n=10/group; parallel design, 6 mg/kg) and dogs (n=4/group; crossover design, 2 mg/kg), as an oral (PO) or as a 3-min intraarterial (IA) infusion in rats and a 6-min intravenous (i.v.) infusion in dogs. Blood, urine, and feces samples were collected and analyzed for unchanged BMS-204352 (plasma) using a validated LC/MS assay and for total radioactivity (plasma, urine, feces) using liquid scintillation counting. The mean total body clearance (CLT) and steady-state volume of distribution (VSS) values for the unchanged BMS-204352 were 2.58 +/- 0.48 l/h/kg and 6.3 +/- 1.14 l/kg, respectively, in rats and 0.21 +/- 0.02 l/h/kg and 4.06 +/- 0.47 l/kg, respectively, in dogs. In both species, the elimination half-life of total radioactivity was significantly longer as compared to the unchanged drug. After IA administration of radiolabeled BMS-204352 to rats, ca. 5.9 and 85% of radioactivity was recovered within 7 days in urine and feces, respectively; corresponding recoveries after PO dosing were 4.5 and 99.5%, respectively. The recoveries were similar in dogs, i.e., ca. 5.2 and 83% of administered radioactivity recovered in urine and feces, respectively, for IV dose and ca. 4 and 86%, respectively, for PO dose. These data indicate that nonrenal (biliary) elimination in both species was predominant. Based on comparable urinary recovery of radioactivity and plasma AUCs of radioactivity, the extent of oral absorption of BMS-204352 appeared to be complete in both species. The absolute oral bioavailability was 55% in rats and 79% in dogs. Bioavailability and extent of absorption data suggest evidence of first pass metabolism of BMS-204352 in the rat and dog.

Administration, Oral↗