PubMed Health⌕ Search

Biomedical subjects

Mark B Willey

Publications and source records attributed to Mark B Willey.

2 recordsLinked to original sources

Effect of double antigen bridging immunoassay format on antigen coating concentration dependence and implications for designing immunogenicity assays for monoclonal antibodies.

The double antigen bridging immunoassay has been used extensively for detection of immunogenicity responses to therapeutic monoclonal antibodies. We have analyzed parameters affecting performance of this type of immunoassay including microtiter plate antigen coating concentration, enzyme-labeled antigen conjugate dilution and assay format (one-step versus two-step). We present results demonstrating that the format of the assay has a significant impact on the optimal parameters to maximize assay performance. A one-step assay format achieves maximal sensitivity across a broad range of coating concentrations and at a lower concentration of conjugate than that in a two-step format. In contrast, a two-step format requires very low coating concentrations and higher conjugate concentrations to achieve maximal sensitivity and suffers from significantly reduced sensitivity at higher coating concentrations. Together, these findings indicate that a one-step assay format can greatly reduce the effect of coating concentration variation on assay performance.

Antibodies, Monoclonal↗

Development, validation, and implementation of a multiplex immunoassay for the simultaneous determination of five cytokines in human serum.

Quantification of biomarkers can provide important information about the safety and efficacy of candidate drugs. Unfortunately, limited sample volume and excess costs often limit analysis of multiple biomarkers. We developed, optimized, validated, and implemented a multiplex immunoassay for simultaneous measurement of multiple circulating cytokines: IL-1beta, TNFalpha, IL-6, IL-8, and IL-10. Multiplex immuoassays were performed using the Luminex LabMAP instrument. Capture antibodies for each cytokine were covalently bound to distinct microsphere subsets distinguished by differing dye ratios. The concentration of each individual cytokine determined by measuring orange fluorescence produced by a complex of a biotinylated cytokine-specific antibody and streptavidin-phycoerythrin. The lower limit of quantification for all assays was 20 pg/mL with the exception of IL-8 which was 100 pg/mL. The inter-assay precision was less than 25%CV for all analytes at all control levels both pre-study and in-study. The percent recovery ranged from 83 to 108% pre-study and 90 to 125% in-study. In a linearity assessment, a 15,000 pg/mL multi-analyte control could be diluted 1:50 and maintain expected accuracy. We measured the cytokine concentrations in more than 2000 serum samples from patients with sepsis. Multiplex results for IL-6 were compared to a conventional commercially available ELISA kit. The degree of agreement between the two methods as measured by the concordance correlation coefficient was 84.5%. Multiplex results were 2.36-fold higher than ELISA values on the average. After adjusting for this mean difference, the 95% empirical limits of agreement for the ratio of individual sample values were 0.33, 2.65. This multiplex immunoassay provided simultaneous measurement of circulating cytokines using 80% less patient specimen compared to traditional approaches and at a significantly decreased cost. Efficient use of this platform requires process improvements to fully maximize the positive impact of multiplex assays in clinical drug development.

Cytokines↗