PubMed Health⌕ Search

Biomedical subjects

Mark C Mammel

Publications and source records attributed to Mark C Mammel.

10 recordsLinked to original sources

Early inhaled nitric oxide therapy in premature newborns with respiratory failure.

BACKGROUND: The safety and efficacy of early, low-dose, prolonged therapy with inhaled nitric oxide in premature newborns with respiratory failure are uncertain. METHODS: We performed a multicenter, randomized trial involving 793 newborns who were 34 weeks of gestational age or less and had respiratory failure requiring mechanical ventilation. Newborns were randomly assigned to receive either inhaled nitric oxide (5 ppm) or placebo gas for 21 days or until extubation, with stratification according to birth weight (500 to 749 g, 750 to 999 g, or 1000 to 1250 g). The primary efficacy outcome was a composite of death or bronchopulmonary dysplasia at 36 weeks of postmenstrual age. Secondary safety outcomes included severe intracranial hemorrhage, periventricular leukomalacia, and ventriculomegaly. RESULTS: Overall, there was no significant difference in the incidence of death or bronchopulmonary dysplasia between patients receiving inhaled nitric oxide and those receiving placebo (71.6 percent vs. 75.3 percent, P=0.24). However, for infants with a birth weight between 1000 and 1250 g, as compared with placebo, inhaled nitric oxide therapy reduced the incidence of bronchopulmonary dysplasia (29.8 percent vs. 59.6 percent); for the cohort overall, such treatment reduced the combined end point of intracranial hemorrhage, periventricular leukomalacia, or ventriculomegaly (17.5 percent vs. 23.9 percent, P=0.03) and of periventricular leukomalacia alone (5.2 percent vs. 9.0 percent, P=0.048). Inhaled nitric oxide therapy did not increase the incidence of pulmonary hemorrhage or other adverse events. CONCLUSIONS: Among premature newborns with respiratory failure, low-dose inhaled nitric oxide did not reduce the overall incidence of bronchopulmonary dysplasia, except among infants with a birth weight of at least 1000 g, but it did reduce the overall risk of brain injury. (ClinicalTrials.gov number, NCT00006401 [ClinicalTrials.gov].).

Administration, Inhalation↗

Effect of dose on response to adrenocorticotropin in extremely low birth weight infants.

CONTEXT: Various cosyntropin doses are used to test adrenal function in premature infants, without consensus on appropriate dose or adequate response. OBJECTIVE: The objective of this study was to test the cortisol response of extremely low birth weight infants to different cosyntropin doses and evaluate whether these doses differentiate between groups of infants with clinical conditions previously associated with differential response to cosyntropin. DESIGN: The design was a prospective, nested study conducted within a randomized clinical trial of low-dose hydrocortisone from November 1, 2001, to April 30, 2003. SETTING: The setting was nine newborn intensive care units. PATIENTS: The patients included infants with 500-999 g birth weight. INTERVENTION: The drug used was cosyntropin, at 1.0 or 0.1 microg/kg, given between 18 and 28 d of birth. MAIN OUTCOME MEASURE: We measured the cortisol response to cosyntropin. RESULTS: Two hundred seventy-six infants were tested. Previous hydrocortisone treatment did not suppress basal or stimulated cortisol values. Cosyntropin, at 1.0 vs. 0.1 microg/kg, yielded higher cortisol values (P < 0.001) and fewer negative responses (2 vs. 21%). The higher dose, but not the lower dose, showed different responses for girls vs. boys (P = 0.02), infants receiving enteral nutrition vs. not (P < 0.001), infants exposed to chorioamnionitis vs. not (P = 0.04), and those receiving mechanical ventilation vs. not (P = 0.02), as well as a positive correlation with fetal growth (P = 0.03). A response curve for the 1.0-microg/kg dose for infants receiving enteral nutrition (proxy for clinically well infants) showed a 10th percentile of 16.96 microg/dl. Infants with responses less than the 10th percentile had more bronchopulmonary dysplasia and longer length of stay. CONCLUSIONS: A cosyntropin dose of 0.1 microg/kg did not differentiate between groups of infants with clinical conditions that affect response. We recommend 1.0 microg/kg cosyntropin to test adrenal function in these infants.

Bronchopulmonary Dysplasia↗

Standardized lung recruitment during high frequency and conventional ventilation: similar pathophysiologic and inflammatory responses in an animal model of respiratory distress syndrome.

OBJECTIVE: To evaluate standardized lung recruitment strategy during both high frequency oscillation (HFO) and volume-targeted conventional ventilation (CV+V) in spontaneously breathing piglets with surfactant washout on pathophysiologic and inflammatory responses. DESIGN: Prospective animal study. SETTING: Research laboratory. SUBJECTS: Twenty-four newborn piglets. INTERVENTIONS: We compared pressure support and synchronized intermittent mandatory ventilation, both with targeted tidal volumes, (PSV+V, SIMV+V) to HFO. Animals underwent saline lavage to produce lung injury, received artificial surfactant and were randomized to one of the three treatment groups (each n=8). After injury and surfactant replacement, lung volumes were recruited in all groups using a standard protocol. Ventilation continued for 6 h. MEASUREMENTS AND MAIN RESULTS: Arterial and central venous pressures, heart rates, blood pressure and arterial blood gases were continuously monitored. At baseline, post lung injury and 6 h we collected serum and bronchoalveolar lavage samples for proinflammatory cytokines: IL 6, IL 8 and TNF-alpha, and performed static pressure-volume (P/V) curves. Lungs were fixed for morphometrics and histopathologic analysis. No physiologic differences were found. Analysis of P/V curves showed higher opening pressures after lung injury in the HFO group compared to the SIMV+V group ( p<0.05); no differences persisted after treatment. We saw no differences in change in proinflammatory cytokine levels. Histopathology and morphometrics were similar. Mean airway pressure (P(aw)) was highest in the HFO group compared to SIMV+V ( p<0.002). CONCLUSIONS: Using a standardized lung recruitment strategy in spontaneously breathing animals, CV+V produced equivalent pathophysiologic outcomes without an increase in proinflammatory cytokines when compared to HFO.

Animals↗

Prophylaxis of early adrenal insufficiency to prevent bronchopulmonary dysplasia: a multicenter trial.

BACKGROUND: Infants developing bronchopulmonary dysplasia (BPD) show decreased cortisol response to adrenocorticotropic hormone. A pilot study of low-dose hydrocortisone therapy for prophylaxis of early adrenal insufficiency showed improved survival without BPD at 36 weeks' postmenstrual age, particularly in infants exposed to histologic chorioamnionitis. METHODS: Mechanically ventilated infants with birth weights of 500 to 999 g were enrolled into this multicenter, randomized, masked trial between 12 and 48 hours of life. Patients received placebo or hydrocortisone, 1 mg/kg per day for 12 days, then 0.5 mg/kg per day for 3 days. BPD at 36 weeks' postmenstrual age was defined clinically (receiving supplemental oxygen) and physiologically (supplemental oxygen required for O2 saturation > or =90%). RESULTS: Patient enrollment was stopped at 360 patients because of an increase in spontaneous gastrointestinal perforation in the hydrocortisone-treated group. Survival without BPD was similar, defined clinically or physiologically, as were mortality, head circumference, and weight at 36 weeks. For patients exposed to histologic chorioamnionitis (n = 149), hydrocortisone treatment significantly decreased mortality and increased survival without BPD, defined clinically or physiologically. After treatment, cortisol values and response to adrenocorticotropic hormone were similar between groups. Hydrocortisone-treated infants receiving indomethacin had more gastrointestinal perforations than placebo-treated infants receiving indomethacin, suggesting an interactive effect. CONCLUSIONS: Prophylaxis of early adrenal insufficiency did not improve survival without BPD in the overall study population; however, treatment of chorioamnionitis-exposed infants significantly decreased mortality and improved survival without BPD. Low-dose hydrocortisone therapy did not suppress adrenal function or compromise short-term growth. The combination of indomethacin and hydrocortisone should be avoided.

Adrenal Insufficiency↗

Clinical validation of a continuous intravascular neonatal blood gas sensor introduced through an umbilical artery catheter.

INTRODUCTION: Arterial blood gas (ABG) values are a necessary diagnostic measurement in the management of critically ill neonates. We hypothesized that a fiberoptic intravascular blood gas sensor, adapted for use through an umbilical artery catheter, would produce blood gas results with clinically acceptable bias and precision, in comparison to laboratory values, but with no blood loss. METHODS: We evaluated a fiberoptic intravascular blood gas sensor (Neotrend) in 23 consecutive neonates suffering respiratory failure. The sensor was inserted into the descending aorta via a 4.0 or 4.5 French umbilical artery catheter and extended 20 mm beyond the catheter tip. Arterial blood samples were drawn as clinically indicated and analyzed using a standard laboratory analyzer. Sensor measurements were recorded at the time of arterial blood sampling. Additionally, we recorded and evaluated data related to umbilical artery catheter placement (low position [L3-L4] vs high position [T8-T10]), duration of sensor functioning and use, and sensor bias and precision compared to the laboratory analyzer (using Bland-Altman technique and linear regression analysis of pH, P(aCO2), and P(aO2)). RESULTS: Duration of sensor use ranged from 1 to 304 hours (3-304 h in high position and 1-91 h in low position). Nine sensors were used for > 72 h (1 in low position and 8 in high position). Nine sensors were placed in low position, with a placement success rate of 56%. Eighteen sensors were placed in high position, with a placement success rate of 89%. The sensor values for pH, P(aCO2), and P(aO2) were strongly correlated (p < 0.0001) with the laboratory-determined values. Bias and precision for all values met standards for discrete analyzers for laboratory use. CONCLUSIONS: The Neotrend device was accurate and reliable in the neonatal setting, allowing blood gas assessment with no iatrogenic blood loss. Catheter placement in high position may increase the likelihood of successful sensor placement and sensor duration of function.

Blood Gas Analysis↗