PubMed Health⌕ Search

Biomedical subjects

Mark C Preul

Publications and source records attributed to Mark C Preul.

25 records · Page 2Linked to original sources

Intraoperative stereoscopic QuickTime Virtual Reality.

OBJECT: The aim of this study was to acquire intraoperative images during neurosurgical procedures for later reconstruction into a stereoscopic image system (QuickTime Virtual Reality [QTVR]) that would improve visualization of complex neurosurgical procedures. METHODS: A robotic microscope and digital cameras were used to acquire left and right image pairs during cranial surgery; a grid system facilitated image acquisition with the microscope. The surgeon determined a field of interest and a target or pivot point for image acquisition. Images were processed with commercially available software and hardware. Two-dimensional (2D) or interlaced left and right 2D images were reconstructed into a standard or stereoscopic QTVR format. Standard QTVR images were produced if stereoscopy was not needed. Intraoperative image sequences of regions of interest were captured in six patients. Relatively wide and deep dissections afford an opportunity for excellent QTVR production. Narrow or restricted surgical corridors can be reconstructed into the stereoscopic QTVR mode by using a keyhole mode of image acquisition. The stereoscopic effect is unimpressive with shallow or cortical surface dissections, which can be reconstructed into standard QTVR images. CONCLUSIONS: The QTVR system depicts multiple views of the same anatomy from different angles. By tilting, panning, or rotating the reconstructed images, the user can view a virtual three-dimensional tour of a neurosurgical dissection, with images acquired intraoperatively. The stereoscopic QTVR format provides depth to the montage. The system recreates the dissection environment almost completely and provides a superior anatomical frame of reference compared with the images captured by still or video photography in the operating room.

Brain↗

A three-dimensional interactive virtual dissection model to simulate transpetrous surgical avenues.

OBJECTIVE: This project involves the development of a three-dimensional surgical simulator called interactive virtual dissection, which is designed to teach surgeons the visuospatial skills required to navigate through a transpetrosal approach. METHODS: A robotically controlled microscope is used for surgical planning and data collection. The spatial anatomic data are recorded from sequentially deeper cadaveric head dissections as a series of superimposed anatomic pictures in stereoscopic digital format. The sequential series of images are then merged to form the final virtual representation. RESULTS: The current three-dimensional virtual reality simulator allows the user to drill the petrous bone progressively deeper and to identify crucial structures much like an experienced surgeon drilling the petrous bone. The program allows surgeons and trainees to manipulate the virtual "surgical field" by interacting with the surgical anatomy. The interactive system functions on a desktop computer. CONCLUSION: The ability to visualize and understand anatomic spatial relationships is crucial in surgical planning, as is a surgeon's confidence in performing the surgery. The virtual reality simulator does not replace the need for practicing surgery on cadavers. However, it is designed to facilitate, via stereoscopic projection, learning how to manipulate a drill in complicated or unfamiliar surgical approaches (e.g., a transpetrosal approach).

Brain↗

Proton magnetic resonance spectroscopic imaging can predict length of survival in patients with supratentorial gliomas.

OBJECTIVE: We compared the ability of proton magnetic resonance spectroscopic imaging ((1)H-MRSI) measures with that of standard clinicopathological measures to predict length of survival in patients with supratentorial gliomas. METHODS: We developed two sets of leave-one-out logistic regression models based on either 1) intratumoral (1)H-MRSI features, including maximum values of a) choline and b) lactate-lipid, c) number of (1)H-MRSI voxels with low N-acetyl group values, and d) number of (1)H-MRSI voxels with high lactate-lipid values, all (a-d) of which were normalized to creatine in normal-appearing brain, or 2) standard clinicopathological features, including a) tumor histopathological grade, b) patient age, c) performance of surgical debulking, and d) tumor diagnosis (i.e., oligodendroglioma, astrocytoma). We assessed the accuracy of these two models in predicting patient survival for 6, 12, 24, and 48 months by performing receiver operating characteristic curve analysis. Cox proportional hazards analysis was performed to assess the extent to which patient survival could be explained by the above predictors. We then performed a series of leave-one-out linear multiple regression analyses to determine how well patient survival could be predicted in a continuous fashion. RESULTS: The results of using the models based on (1)H-MRSI and clinicopathological features were equally good, accounting for 81 and 64% of the variability (r(2)) in patients' actual survival durations. All features except number of (1)H-MRSI voxels with lactate-lipid/creatine values of at least 1 were significant predictors of survival in the (1)H-MRSI model. Two features (tumor grade and debulking) were found to be significant predictors in the clinicopathological model. Survival as a continuous variable was predicted accurately on the basis of the (1)H-MRSI data (r = 0.77, P < 0.001; median prediction error, 1.7 mo). CONCLUSION: Our results suggest that appropriate analysis of (1)H-MRSI data can predict survival in patients with supratentorial gliomas at least as accurately as data derived from more invasive clinicopathological features.

Adult↗

Toward optimal tissue sealants for neurosurgery: use of a novel hydrogel sealant in a canine durotomy repair model.

OBJECTIVE: Watertight dural repairs are difficult to achieve, and cerebrospinal fluid leakage causes complications and extends hospital stays. Therefore, a novel synthetic hydrogel film was evaluated as an adjunct to dural closure in a canine model. METHODS: The self-polymerizing, absorbable, and biocompatible hydrogel was sprayed onto tissue and formed a flexible, adherent sealant. A 2-cm incision of cranial dura and arachnoid was created in 26 adult dogs and loosely repaired. Hydrogel was applied over the 2-mm dural gap in 13 dogs; 13 control dogs received no hydrogel application. RESULTS: All dogs remained neurologically intact. Valsalva tests conducted at 1, 4, 7, and 56 days were associated with mean leakage pressures (+/- standard error of the mean) of 5 +/- 0, 5 +/- 0, 7 +/- 2, and 13 +/- 8 cm H(2)O in the controls and of 53 +/- 2, 37 +/- 11, 42 +/- 6, and 48 +/- 4 in the treated animals (P = 0.001, 0.053, 0.010, 0.035, respectively, at each time point; one-tailed t test). Histopathological analysis revealed minimal changes. CONCLUSION: The hydrogel-treated animals exhibited normal progression of dural healing, no dural adhesions, and no underlying effects on the brain. Although dural healing progressed normally, the control animals displayed marked peridural adhesions. The results of this in vivo study suggest that hydrogels, such as that used here, may significantly decrease cerebrospinal fluid leakage, thereby increasing the safety and effectiveness of dural closure in patients and facilitating surgical reexploration.

Animals↗

Craniovertebral junction fixation with transarticular screws: biomechanical analysis of a novel technique.

OBJECT: The authors compared the biomechanical stability resulting from the use of a new technique for occipitoatlantal motion segment fixation with an established method and assessed the additional stability provided by combining the two techniques. METHODS: Specimens were loaded using nonconstraining pure moments while recording the three-dimensional angular movement at occiput (Oc)-C1 and C1-2. Specimens were tested intact and after destabilization and fixation as follows: 1) Oc-C1 transarticular screws plus C1-2 transarticular screws; 2) occipitocervical transarticular (OCTA) plate in which C1-2 transarticular screws attach to a loop from Oc to C-2; and (3) OCTA plate plus Oc-C1 transarticular screws. Occipitoatlantal transarticular screws reduced motion to well within the normal range. The OCTA loop and transarticular screws allowed a very small neutral zone, elastic zone, and range of motion during lateral bending and axial rotation. The transarticular screws, however, were less effective than the OCTA loop in resisting flexion and extension. CONCLUSIONS: Biomechanically, Oc-C1 transarticular screws performed well enough to be considered as an alternative for Oc-C1 fixation, especially when instability at C1-2 is minimal. Techniques for augmenting these screws posteriorly by using a wired bone graft buttress, as is currently undertaken with C1-2 transarticular screws, may be needed for optimal performance.

Adult↗

Interactive stereoscopic virtual reality: a new tool for neurosurgical education. Technical note.

The goal of this study was to develop a new method for neurosurgical education based on interactive stereoscopic virtual reality (ISVR). Interactive stereoscopic virtual reality can be used to recreate the three-dimensional (3D) experience of neurosurgical approaches much more realistically than standard educational methods. The demonstration of complex 3D relationships is unrivaled and easily combined with interactive learning and multimedia capabilities. Interactive stereoscopic virtual reality permits the accurate recreation of neurosurgical approaches through integration of several forms of stereoscopic multimedia (video, interactive anatomy, and computer-rendered animations). The content explored using ISVR is obtained through a combination of approach-based cadaver dissections, live surgical images and videos, and computer-rendered animations. These media are combined through an interactive software interface to demonstrate key aspects of a neurosurgical approach (for example, patient positioning, draping, incision, individual surgical steps, alternative steps, relevant anatomy). The ISVR platform is designed for use on a desktop personal computer with newly developed, inexpensive, platform-independent shutter glasses. Interactive stereoscopic virtual reality has been used to capture the anatomy and methods of several neurosurgical approaches. In this paper the authors report their experience with ISVR and describe its potential advantages. The success of a neurosurgical approach is contingent on the mastery of complex, 3D anatomy. A new technology for neurosurgical education, ISVR can improve understanding and speed the learning process. It is an effective tool for neurosurgical education, bridging the substantial gap between textbooks and intraoperative training.

Computer-Assisted Instruction↗

In vivo assessment of calcium alginate gel for endovascular embolization of a cerebral arteriovenous malformation model using the Swine rete mirabile.

OBJECTIVE: We sought to assess the stability of calcium alginate as an embolic agent in an animal model of a cerebral arteriovenous malformation (AVM). Swine cerebral AVM models were used to test the injectability, radiographic visualization, mechanical stability, and biocompatibility of calcium alginate as an occlusive agent. METHODS: The swine cerebral AVM model included a carotid-to-jugular anastomosis to increase flow to the rete mirabile (RM), thereby simulating the pressure gradient and shunted blood flow of an AVM. Alginate and the reactive component, calcium chloride, were injected from double-lumen microcatheters to form a complete RM occlusion in the "acute swine" AVM model and a partial occlusion in a "survival swine" model. RESULTS: Angiographic and histological results verified complete occlusion of the left RM in acute animals when alginate was injected in stages. Partial RM occlusion in the survival animals blocked blood flow to the inferior portion of the RM but left flow open to the superior portion of the RM and the circle of Willis. One-week survival results showed that the alginate remained a stable occlusive material. Histological results showed a minor bioactive response and encapsulation of the alginate polymer, thereby increasing the stability and effective occlusion of the embolization material. CONCLUSION: Calcium alginate proved to be an effective endovascular occlusion material that blocked blood flow to the swine RM. The swine AVM models provided assessment of alginate injectability and effective occlusion and provided initial in vivo characteristics of alginate stability and biocompatibility.

Alginates↗