Mark E Ladd

Publications and source records attributed to Mark E Ladd.

At least 19 recordsLinked to original sources

Whole-body MR vascular screening detects unsuspected concomitant vascular disease in coronary heart disease patients.

Coronary heart disease (CHD) patients often show atherosclerotic vascular disease in other vascular territories. We evaluated how often whole-body MR imaging detects concomitant arterial pathologies in CHD patients, and how often these pathologies were not known to the patients previously. Of 4,814 participants in the population-based Heinz Nixdorf Recall Study, 327 reported CHD (i.e., previous coronary bypass surgery, angioplasty); of those, 160 patients (mean age 66.4 years) were examined using MR of the brain, the heart (excluding the coronary arteries), and whole-body MR angiography. The prevalence of each vascular pathology was assessed, correlated to the others and compared to patients' histories. Of the 160 CHD patients, 16 (10%) showed MR signs of stroke, and 77 (48.1%) had a stenosis >50% in at least one extracerebral peripheral artery (other than the coronaries), including 28 (17.5%) with relevant renal artery stenoses, and 20 (12.5%) with relevant extracerebral internal carotid artery stenoses. False negative histories were reported in 12 of 81 cases with myocardial infarctions, and in 11 of 16 cases with cerebrovascular infarctions. This whole-body atherosclerosis MR screening program allows previously unknown concomitant vascular disease to be detected in coronary heart disease patients. Its prospective value should be assessed in further studies.

Aged↗

Real-time vascular interventional magnetic resonance imaging: the future of aortic stent-graft placement?

Endovascular stent-graft placement is emerging as a promising alternative to medical and surgical treatment of patients with diseases of the descending thoracic and abdominal aorta. Precise placement of the stentgraft, which is currently performed under x-ray control, remains, however, challenging as there are several shortcomings to fluoroscopic guidance beyond that related to the harmful effect of radiation exposure and nephrotoxic contrast media. While transesophageal echocardiography and intravascular ultrasound have been used as adjunct imaging modalities during endovascular stent-graft procedures to overcome the limitations of angiography, these techniques have not mitigated the need for fluoroscopy. Magnetic resonance imaging (MRI) guidance of vascular interventional procedures offers several potential advantages over fluoroscopy-guided techniques, including image acquisition in any desired orientation, superior 3D soft-tissue contrast with simultaneous visualization of the interventional device, absence of ionizing radiation, and avoidance of nephrotoxic contrast media. Magnetic resonance imaging is often used for pre-operative diagnosis of aortic disease and can provide all relevant information for the planning of endovascular stent-graft procedures as well as for accurate and immediate post-interventional evaluation. However, visualization of interventional instruments by MRI has proven to be the chief obstacle. This article will review current approaches that have been developed for depicting vascular instruments by MRI and will also discuss the first experimental experiences with MRI-guided endovascular stent-graft placement in a swine model of aortic dissection.

Aorta, Abdominal↗

Feasibility of real-time magnetic resonance-guided stent-graft placement in a swine model of descending aortic dissection.

AIMS: To evaluate the pre-clinical feasibility of real-time magnetic resonance imaging (rtMRI) to guide stent-graft placement for experimental aortic dissection (AD) and to alleviate disadvantages of ionising radiation and nephrotoxic contrast media. Endovascular stent-graft placement for thoracic aortic disease is usually performed under X-ray guidance. The feasibility of rtMRI-guided stent-graft placement is currently not known. METHODS AND RESULTS: By using a catheter-based technique, dissections of the descending thoracic aorta were successfully created in eight domestic pigs. Subsequent implantation of commercially available, nitinol-based stent-grafts was performed entirely under rtMRI guidance. By pre-interventional MRI, the mean minimal true-lumen diameter was 0.9 (0.825-0.975) cm. rtMRI permitted not only the successful and safe device navigation within the true lumen from the iliac arteries to the thoracic aorta, but also the precise positioning and deployment of the stent-graft and safe withdrawal of the delivery catheter in seven of eight pigs. This was achieved without any other complications. After the stent-graft placement, MRI demonstrated complete obliteration of the false lumen, which was confirmed at autopsy. All stent-grafts were well expanded resulting in an increase in the size of the true-lumen diameter to 2.05 (1.925-2.1) cm (P=0.066 vs. baseline). CONCLUSION: In experimental AD, rtMRI-guided endovascular stent-graft placement is feasible and safe and has the potential for mitigating radiation and contrast-related side effects. Additionally, it allows not only pre-interventional diagnosis and detailed anatomic diagnosis, but also permits immediate post-interventional, anatomical, and functional delineation of procedure success that may serve as a baseline for future comparison during follow-up.

Aortic Dissection↗

Accelerating MR elastography: a multiecho phase-contrast gradient-echo sequence.

PURPOSE: To demonstrate the feasibility of using a multiecho phase-contrast (PC) gradient-echo sequence with motion-sensitizing gradient (MSG) to accelerate MR elastography (MRE) acquisitions in comparison to single-echo PC sequences. MATERIALS AND METHODS: The sequence was implemented and compared with a conventional single-echo sequence as the standard of reference in both agarose phantoms and in vivo in the biceps of three healthy volunteers. For reconstruction of the elasticity modulus, a local frequency estimation (LFE) algorithm was used. ETL factors of 1-16 were evaluated. RESULTS: Phantom experiments demonstrated excellent consistency between single-echo and multiecho measurements in terms of wave equivalency, SNR, and reconstructed shear modulus. Additionally, the in vivo MRE examinations showed an excellent correspondence to the single-echo results. Minor loss of wave amplitude was observed at higher ETL factors. CONCLUSION: The results demonstrate that a multiecho sequence is suitable for accelerating MRE in nearly homogeneous tissue, such as muscle. It provides equivalent elasticity values in a significantly reduced scan time compared to a single-echo sequence. The maximum achievable ETL factor must be individually determined for the target tissue.

Acceleration↗

Oscillating steady states.

The signal formation and properties of steady-state free precession (SSFP) in combination with alternating RF pulse phases or alternating spin precession is analyzed. Simulations and experiments demonstrate that the amplitudes of SSFP echo paths are significantly influenced by application of alternating phases either via the exciting RF pulse or via some external mechanism producing alternating spin precession. The influence of alternating phases on echo amplitudes is different for different echo paths. The primary SSFP echo paths F(0) (-) and F(0) (+) exhibit a signal reduction whereas higher-order echoes F(-1) (-) and F(1) (+) show a signal increase upon application of oscillating phases. This behavior can be described using a simple perturbation theory applied to the frequency response profile of balanced SSFP combined with a final signal integration over one balanced SSFP band. The high sensitivity of SSFP echo amplitudes to alternating RF pulse phases or precession is exemplarily used to detect and visualize propagating transverse acoustic shear waves. Detection of flow or alternating currents are further possibilities to apply this unique feature of SSFP.

Magnetic Resonance Imaging↗

High-resolution continuously acquired peripheral MR angiography featuring partial parallel imaging GRAPPA.

Continuously-moving-table MRI, in contrast to traditional multistation techniques, potentially can improve the scan time efficiency of whole-body applications and provide seamless images of an extended field of view (FOV). Contrast-enhanced MR angiography (CE-MRA) in particular requires high spatial resolution and at the same time has rigid scan time constraints due to the limited arterial contrast window. In this study a reconstruction method for continuously acquired 3D data sets during table movement was combined with a self-calibrated partial parallel imaging algorithm (generalized autocalibrating partially parallel acquisitions (GRAPPA)). The method was applied to peripheral CE-MRA and compared with a standard continuously-moving-table MRA protocol. The gain in scan time was used to increase the data acquisition matrix and decrease the slice thickness. The method was evaluated in five healthy volunteers and applied to one patient with peripheral arterial occlusive disease (PAOD). The protocols were intraindividually compared with respect to the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in selected vessel segments, as well as overall vessel depiction. The combination of the continuously-moving-table technique with parallel imaging enabled the acquisition of seamless peripheral 3D MRA with increased resolution and an overall crisper appearance.

Algorithms↗

In vitro evaluation of current thoracic aortic stent-grafts for real-time MR-guided placement.

PURPOSE: To systematically evaluate the magnetic resonance imaging (MRI) characteristics of current thoracic aortic stent-graft devices before, during, and after in vitro deployment as a step toward real-time MRI-guided stent placement. METHODS: Six stent-graft devices used for thoracic aortic repair were examined in a dedicated phantom model using a 1.5-T MRI scanner. First, the delivery systems with the mounted stent-graft were examined using real-time fast imaging with steady-state precession (TrueFISP) with Cartesian and radial k-space filling. TrueFISP imaging was subsequently used for real-time monitoring of stent-graft expansion. The deployed stent-grafts were then examined in a water bath containing gadolinium (1:40) with high-resolution T1-weighted 3D fast low-angle shot (FLASH) sequences. The images were analyzed for artifacts, radiofrequency caging effects, and device visualization quality. RESULTS: Three delivery systems with mounted stent-grafts did not contain ferromagnetic elements and were well visualized. Imaging with radial k-space filling showed fewer artifacts than Cartesian imaging. Movement of the delivery system and stent-graft expansion of these devices were successfully demonstrated at a rate of up to 6 frames per second. Evaluation of the expanded stent-grafts revealed only minor susceptibility artifacts without relevant signal attenuation in the stent-graft lumen for 5 nitinol-based stent-grafts. Only a stainless steel-based stent-graft was associated with severe artifacts, thwarting visualization of its lumen or surroundings. CONCLUSION: The present study shows that 3 nitinol-based thoracic stent-graft devices are potentially suited for real-time MRI-guided placement with respect to both the delivery system and the stent-graft itself. These observations provide the basis for the evaluation of MRI-guided stent-graft placement in vivo.

Alloys↗

Cerebellar activation patterns in deaf participants for perception of sign language and written text.

To address the influence of language presentation on cerebellar activation, hearing volunteers were compared with deaf individuals using functional magnetic resonance imaging during observation of German sign language and text reading. In deaf participants, German sign language revealed activation of the auditory and language-related areas including the medial temporal gyrus (BA 21) and Crus I. In normal hearing participants not understanding German sign language, Crus I was less activated during observation of German sign language but strongly activated during text reading and accompanied by activation of the medial temporal gyrus. Our results indicate that cerebellar activation in Crus I corresponds to language perception as correlated with cortical activation in language-related areas and is not dependent on the mode of language presentation.

Adolescent↗

Magnetic resonance imaging of autologous fat grafting.

A 30-year-old female patient with isolated facial lipodystrophy underwent two sessions of fat injection. MR signals of injected fat at different injection ages were compared to native fat. Native T1 signal was smaller for transplant fat, probably due to a slightly lower fat content and/or fibrosis or due to higher perfusion. T2 signal of transplants was significantly higher than that of native fat. T1 post-contrast was also higher, and contrast uptake of transplanted fat increased slightly with transplant age, which could be explained by an increasing perfusion. This study demonstrates the differences and MR signal time changes of native and transplanted fat.

Adipose Tissue↗

Comparison of volume, four- and eight-channel head coils using standard and parallel imaging.

Array coils can potentially offer increased signal-to-noise ratio (SNR) over standard coils adjacent to the array elements, while preserving the SNR at the center of the volume. The SNR advantage should theoretically increase with the number of array elements. Parallel acquisition techniques (PAT), on the other hand, can benefit acquisition times or spatial resolution at a cost to SNR as well as image quality. This study examines the question of whether SNR and image quality are still acceptable with two different array coils (four and eight channels) in conjunction with PAT when compared to standard imaging with a volume coil. All imaging was on a 1.5 T MR scanner. T2-weighted, FLAIR, diffusion-weighted, and time of flight (TOF) angiography images were performed with and without PAT in a phantom and in ten healthy volunteers. The phantom measurements demonstrated superior SNR for the eight-channel coil versus the four-channel and standard head coils. Using the eight-channel head coil for in vivo imaging, image quality with PAT (acceleration factor=2) was scored similar to images without PAT using the volume coil. The four-channel head coil suffered from inhomogeneity, lower SNR and poorer image quality when using PAT compared to standard imaging with the volume head coil. Both the in vivo and the phantom results indicate that the eight-channel head coil should be used for the highest quality brain images; this coil can be combined with PAT sequences for shorter acquisition time without a significant decrease in image quality relative to a volume coil without PAT.

Adult↗

Parallel acquisition techniques for accelerated volumetric interpolated breath-hold examination magnetic resonance imaging of the upper abdomen: assessment of image quality and lesion conspicuity.

PURPOSE: To evaluate the impact of parallel acquisition techniques (PATs) on image quality and detection of liver metastases using three-dimensional volumetric interpolated breath-hold examination (VIBE) for clinical liver imaging. MATERIALS AND METHODS: Forty-nine patients with various primary malignancies underwent abdominal dynamic contrast-enhanced three-dimensional VIBE magnetic resonance imaging (MRI) (1.5 T) using a standard phased array coil. Recently introduced Generalized Autocalibrating Partially Parallel Acquisition (GRAPPA) and SENSitivity Encoding (mSENSE) PAT reconstruction algorithms were added to reduce scan time twofold. Overall image quality, motion, and aliasing artifacts were classified on a 5-point scale. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements were performed for quantitative comparison. All sequences were evaluated concerning the number of detected lesions. RESULTS: PAT resulted in a reduction of data acquisition time from 23 to 13 seconds. Both GRAPPA and mSENSE data sets yielded 30% less SNR (34.8 +/- 14.1 and 33.1 +/- 13.3, P < 0.001) and 35% less CNR (21.2 +/- 15.0 and 20.9 +/- 12.7, P < 0.05) in comparison to unaccelerated VIBE (SNR = 50.8 +/- 20.3/CNR = 32.5 +/- 19.1). Similarly, PAT revealed lower-image-quality scores than unaccelerated VIBE. GRAPPA resulted in more fold-over artifacts than mSENSE. mSENSE revealed slightly fewer motion artifacts than no PAT. The unaccelerated late-venous-phase VIBE sequence revealed 146 lesions in the same patients. Accelerated images with mSENSE reconstruction detected 138 lesions. GRAPPA revealed 127 lesions, and thus performed inferior to mSENSE. CONCLUSION: At least for arrays with small numbers of elements, such as arrays used in this study, the PAT-induced reduction in scanning times must be weighed against compromises in image quality, which translate into poorer diagnostic performance regarding detection of small hepatic lesions. Thus, the PAT implementations tested in this study should probably be reserved for patients unable to hold their breaths for regular three-dimensional VIBE data sets.

Abdomen↗

Interventional magnetic resonance angiography with no strings attached: wireless active catheter visualization.

Active instrument visualization strategies for interventional MR angiography (MRA) require vascular instruments to be equipped with some type of radiofrequency (RF) coil or dipole RF antenna for MR signal detection. Such visualization strategies traditionally necessitate a connection to the scanner with either coaxial cable or laser fibers. In order to eliminate any wire connection, RF resonators that inductively couple their signal to MR surface coils were implemented into catheters to enable wireless active instrument visualization. Instrument background to contrast-to-noise ratio was systematically investigated as a function of the excitation flip angle. Signal coupling between the catheter RF coil and surface RF coils was evaluated qualitatively and quantitatively as a function of the catheter position and orientation with regard to the static magnetic field B0 and to the surface coils. In vivo evaluation of the instruments was performed in interventional MRA procedures on five pigs under MR guidance. Cartesian and projection reconstruction TrueFISP imaging enabled simultaneous visualization of the instruments and vascular morphology in real time. The implementation of RF resonators enabled robust visualization of the catheter curvature to the very tip. Additionally, the active visualization strategy does not require any wire connection to the scanner and thus does not hamper the interventionalist during the course of an intervention.

Animals↗

Whole-body magnetic resonance imaging featuring moving table continuous data acquisition with high-precision position feedback.

A novel setup for whole-body MR imaging with moving table continuous data acquisition has been developed and evaluated. The setup features a manually positioned moving table platform with integrated phased-array surface radiofrequency coils. A high-precision laser position sensor was integrated into the system to provide real-time positional data that were used to compensate for nonlinear manual table translation. This setup enables continuous 2D and 3D whole-body data acquisition during table movement with surface coil image quality. The concept has been successfully evaluated with whole-body steady-state free precession (TrueFISP) anatomic imaging in five healthy volunteers. Seamless coronal and sagittal slices of continually acquired whole-body data during table movement were accurately reconstructed. The proposed strategy is potentially useful for a variety of applications, including whole-body metastasis screening, whole-body MR angiography, large field-of-view imaging in short bore systems, and for moving table applications during MR-guided interventions.

Algorithms↗

A diffusion tensor imaging analysis of gender differences in water diffusivity within human skeletal muscle.

The diffusive properties of adjacent muscles at rest were evaluated in male (n = 12) and female (n = 12) subjects using diffusion tensor imaging (DTI). The principle, second and third eigenvalues, trace of the diffusion tensor [Tr(D)], and two anisotropic parameters, ellipsoid eccentricity (e) and fractional anisotropy (FA), of various muscles in the human calf were calculated from the diffusion tensor. Seven muscles were investigated in this study from images acquired of the left calf: the soleus, lateral gastrocnemius, medial gastrocnemius, posterior tibialis, anterior tibialis, extensor digitorum longus and peroneus longus. A mathematical model was also derived that relates the eigenvalues of the diffusion tensor to the muscle fiber volume fraction, which is defined as the volume of muscle fibers within a well-defined arbitrary muscle volume. Females on average had higher eigenvalues and Tr(D) compared with males, with the majority of muscles being statistically different between the sexes. In contrast, males on average had higher e and FA than females, with the large plantar flexors--soleus, lateral gastrocnemius, and medial gastrocnemius--producing statistically different results. The behavior of the mathematical model for variations in fiber volume fraction produced similar trends to those seen when the experimental data were fit to the model. The model predicts that a larger volume fraction of skeletal muscle in males is devoted to fibers than in females, but the true underlying source of the gender discrepancy remains unclear. Although the model does not fully account for other transport processes, it does provide some insight into the limiting factors that affect the diffusion of water in skeletal muscle measured by DTI.

Adult↗

Detection of pulmonary nodules using a 2D HASTE MR sequence: comparison with MDCT.

OBJECTIVE: The objective of our study was to determine the diagnostic performance of MRI based on a HASTE sequence for the detection of pulmonary nodules in comparison with MDCT. MATERIALS AND METHODS: Thirty patients with known pulmonary nodules underwent both MRI and CT. CT of the lung served as the standard of reference and was performed on a 4-MDCT scanner using a routine protocol. MRI was performed with axial and coronal HASTE sequences using a high-performance 1.5-T MR scanner. Image data were analyzed in three steps after completion of all data acquisition. Step 1 was the analysis of all the CT image data. Step 2 was the analysis of all the MR image data while blinded to the results of the CT findings. Step 3 closed with a simultaneous review of all corresponding CT and MRI data, including a one-to-one correlation of the size and location of all the nodules that were detected. RESULTS: Compared with the sensitivity of CT, the sensitivity values for the HASTE MR sequence were as follows: 73% for lesions less than 3 mm, 86.3% for lesions between 3 and 5 mm, 95.7% for lesions between 6 and 10 mm, and 100% for lesions larger than 10 mm. The overall sensitivity of the HASTE sequence for the detection of all pulmonary lesions was 85.4%. CONCLUSION: An MRI examination that consists of a HASTE sequence allows one to detect, exclude, or monitor pulmonary lesions that are 5 mm and bigger. Suspicious lesions smaller than 5 mm still need to be validated using CT.

Adult↗

Water excitation: a possible pitfall in cerebral time-of-flight angiography.

BACKGROUND AND PURPOSE: Time-of-flight MR angiography (TOF MRA), with its advantage of high spatial resolution, is widely used for visualization of intracranial arteries. Fat signal intensity from bone marrow can interfere with vessel signal intensity, especially in maximum intensity projection reconstructions. Use of a technique such as fat saturation or water excitation can reduce this signal intensity. METHODS: Ten volunteers were included in this study. TOF MRA was performed by using spoiled gradient echo sequences on a 1.5-T MR unit either with or without water excitation. Water excitation was performed by using a binomial excitation pulse pair, with a null in the excitation profile at the fat frequency to obtain fat suppression. Two blinded neuroradiologists then judged the images. Additional studies by using a phantom with a flow of about 2 mL/s were performed under the same conditions. Image quality obtained with and that without water excitation was graded as similar by both neuroradiologists. RESULTS: As the main finding, the sequences by using water excitation revealed an important pitfall: apparent carotid artery stenosis was detected in 4/10 and occlusions in 1/10 cases. Use of a flow phantom could reveal the same pitfall. Intracranial vessel disease was excluded in all volunteers by using Doppler sonography. CONCLUSION: The type of water excitation tested here can induce significant artifacts in cerebral TOF MRA. These artifacts can be misinterpreted as carotid artery stenosis or even occlusion, whereas the benefit brought by water excitation with respect to fat suppression is less significant.

Adult↗

Cerebral activation using a MR-compatible piezoelectric actuator with adjustable vibration frequencies and in vivo wave propagation control.

Functional magnetic resonance imaging (fMRI) studies are increasingly used in patients with brain tumors near the sensory motor cortex for planning of therapy. Passive stimuli can be helpful for reproducible results. The purpose of our study was to investigate frequency and amplitude dependencies of cerebral activation patterns using a vibratory stimulus that involves sensory and motor function and allows exact adjustment of vibratory frequencies and direct control of penetration depth into the tissue. Fifteen volunteers were studied with fMRI during vibratory stimulation of the right biceps muscle utilizing a block design (frequencies: 150 and 300 Hz, amplitudes: 400, 600, and 800 microm). In addition, visualization of the wave propagation into the biceps tissue itself was performed with a modified phase contrast sequence. A specially developed MR-compatible mechanical oscillator was used to apply the vibrotactile sensations. fMRI revealed activation of the left primary somatosensory cortex during application of both vibratory frequencies. Additionally, activity of the primary and supplementary motor cortex was revealed using 150-Hz stimuli, while only minimal at 300 Hz. The activity strength correlated with increasing stimulus amplitudes and the visualized penetration depth. Activation of motor areas was more pronounced at the beginning of the rest period. In conclusion, sensory motor areas can be activated using a piezoelectric actuator, with less pronounced motor area activation at higher frequencies. Our setup allowed local control of stimulus penetration through the tissue correlated to central activation, providing objective stimulus control. The pronounced activation of the motor cortex during the rest condition may reflect the subjective feeling of arm movement after the end of the stimulus.

Adolescent↗

Increased time rate of change of gradient fields: effect on peripheral nerve stimulation at clinical MR imaging.

PURPOSE: To increase gradient stimulation from 100% to a fixed 120% level and to assess patient acceptance of the degree of peripheral nerve stimulation (PNS) at magnetic resonance (MR) imaging. MATERIALS AND METHODS: Two hundred ten patients underwent MR imaging of various body regions according to clinical indications. An additional three-dimensional fast low-angle shot sequence with the 120% stimulation level was performed. A patient questionnaire was distributed after MR imaging to document the presence, degree, and location of PNS. Degree was measured with an 11-point scale (score range, 0-10). Age was analyzed between the sexes for significant statistical differences. Furthermore, correlation between location of examination and location and degree of stimulation was performed. To determine stimulation discomfort relative to other factors typically present at MR imaging, the degree of discomfort due to room temperature, size of magnet bore, acoustic noise, examination time, and heating sensation was determined for comparison, as well. RESULTS: Thirty-five (16.7%) patients reported a stimulation sensation during imaging in one or more locations, while six (2.9%) felt very uncomfortable local stimulation (score of 8-10). No significant difference between male and female patients regarding age, sex, and appearance or degree of stimulation sensation could be detected. No significant correlation between location of examination and location and degree of stimulation was recorded. Compared with other side effects, PNS was considered relatively unimportant. CONCLUSION: The 120% gradient stimulation level seems acceptable for routine clinical imaging with this gradient system, since only 2.9% of patients experienced very uncomfortable local stimulation.

Adolescent↗